HARISON INDUSTRIAL DEHUMIDIFIER - USER'S MANUAL - Model: HD-100BM
Warning :
The use life will be prolonged if checking, maintaining periodically. Please send
professional person to damage.
6. TROUBLES AND COUNTERMEASURES
Phenomenon
analysis of causes
Countermeasures
Machine does not run.
Power failure
Power source is not
switched on not well
plugged
Fuse is broken
Switch on the power source
plug in
Replace the fuse after
removing troubles
Machine can not dehumidify
or the effect is bad.
Air filter dusted
Air inlet and outlet
obstructed door or window
is open
Refrigerant leakage
Clean the air filter
Remove the obstacle
Close the door and the
window, shade the sun with
curtains, etc.
Contact dealer and repair it
Water leakage
Machine inclined backward
Drain pipe is blocked
Level the unit
Remove the front panel and
wipe off dirt from the pipe
"POWER/PROTECTION"
light flashes.
The temperature sensor is
open circuit or short circuit.
Replace the temperature
sensor
Machine can not defrost
The temperature sensor is
loosening.
The valve is damaged.
Fix the temperature sensor
well
Replace the valve
If the troubles have not been removed yet, please contact the dealer.
When the dehumidifier is starting or stopping, the sound of the cycling of refrigerant
does not mean a trouble.
It is normal that hot wind is discharged the air outlet.
Notice
Please switch off the power source after stopping.
Must be grounded reliably when installing.
Please keep this manual in a suitable storage for reference.
PLEASE CONTACT YOUR NEAREST HARISON SUPPLIER FOR ANY
TECHNICAL ASSISTANCE !