HI 6020IT and HI 6020JB User Guide 

 

Page | 5 

 

Chapter 2 

Specifications and Features 

• • • • • • 

Chapter 2 provides specifications for HI 6020 Summing Box series instruments. The specifications listed are 
designed to assist in the installation, operation and troubleshooting of your summing box. All service 
personnel should be familiar with this section before installing or repairing the instrument. 

 

Basic Specifications 

There are two main configurations for the HI 6020 summing box.  

1.

 

The HI 6020JB which includes a summing board without INTEGRATED TECHNICIAN® (IT)

 

2.

 

The HI 6020IT which includes a summing board with INTEGRATED TECHNICIAN® (IT)

 

 

The HI 6020JB-SSX-Y provide different options. 
Where:

 

SS:   stainless steel enclosure

 

X: 

X= 1

 without trim pots or  

 

X= 2

 with trim pots

 

Y: 

Y = blank

 is a 5-hole summing box enclosure  

 

Y = 6

 is a 6-hole summing box enclosure enabling connection to a second summing box 

 

 

The HI 6020JB and HI 6020IT is provided with cable glands and has approval for use in the following 
hazardous areas:   
Class I, Division 1, Groups A, B, C, D, T4 
Class II, Division 1, Groups E, F, G, T4 
Class III, Division 1, T4 
Class I, Zone 0, Group IIC, T4 
Class II, Zone 20, Group IIIC, T4 
 
Class I, Division 2, Groups A, B, C, D, T5 
Class II, Division 2, Groups F, G, T5 
Class III, Division 2, T5 

 

IMPORTANT NOTE:  

Only the stainless steel versions of the HI 6020JB and HI 6020IT junction boxes are certified for use in 
hazardous areas.   

 

HI 6020IT and HI 6020JB  

Number of Load Cells Supported 

8 (requires two summing boxes, one 6-hole summing box and one 5-hole summing box) 

4 (requires only one 5-hole summing box) 

 

Enclosure 

Stainless Steel 

 

PCB Dimensions 

4.88" (12.38 cm) x 4.88" (12.38 cm) 

 

Summary of Contents for HI 6020IT

Page 1: ...nd HI 6020JB US Canada Hazardous Locations User Guide Class I II III Division 1 Class I Zone 0 and Zone 20 Hardy Process Solutions Document Number 0596 0352 01 REV B CONTROLLED DOCUMENT CHANGES MAY NO...

Page 2: ...L WHO ARE FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF ALL COMPONENTS IN THE SYSTEM AND THE POTENTIAL HAZARDS INVOLVED FAILURE TO OBSERVE THIS PRECAUTION COULD RESULT IN BODILY HARM AND OR PROPERTY...

Page 3: ...abilities 7 Hardy Process Toolbox 7 C2 and Calibration 7 INTEGRATED TECHNICIAN 7 Chapter 3 8 Installation of Intrinsically Safe HI 6020 IT and HI 6020JB Summing Boxes into Hazardous Classified Locatio...

Page 4: ...ox is a critical component in a weighing system that enables use of Hardy s core technologies C2 electronic calibration and Integrated Technician IT Each summing box distributes excitation voltage to...

Page 5: ...thout trim pots or X 2 with trim pots Y Y blank is a 5 hole summing box enclosure Y 6 is a 6 hole summing box enclosure enabling connection to a second summing box The HI 6020JB and HI 6020IT is provi...

Page 6: ...iew the installation section for additional information Trim Pot Number of Turns 11 for use with non C2 systems Trim Pot Impedance Range 0 10 Power Rating Non Hazardous Safe area Locations Class I and...

Page 7: ...the need for test weights A C2 weighing system consists of up to eight load cell sensors per HI 6020 IT or JB summing box C2 interconnect cable and a Hardy instrument controller or module with C2 Each...

Page 8: ...atus manufacturer s installation drawing must be followed when installing this equipment 2 Resistance between Intrinsically Safe Ground and earth ground must be lessthan 1 0 Ohm 3 Install Intrinsic Sa...

Page 9: ...t controller or module you will need a summing cardorsummingboxtoaggregatethesignalstoprovideasingularweight reading Whileaplatform benchor floorscalehasabuiltinsummingcardtoperformthisfunction loadce...

Page 10: ...n C2 load sensor wiring Hardy load sensor with C2 wiring WARNING To prevent ignition of flammable or combustible atmospheres disconnect power before servicing CAUTION Observe precautions for electrost...

Page 11: ...D ASSOCIATED APPARATUS FOR USE IN CLASS I II III DIVISION 1 HAZARDOUS CLASSIFIED LOCATIONS Edition 8 Revision Date 2015 04 28 CSA C22 2 NO 157 92 INTRINSICALLY SAFE AND NON INCENDIVE EQUIPMENT FOR USE...

Page 12: ...HI 6020IT and HI 6020JB User Guide Page 12 This page intentionally left blank...

Page 13: ...ns are EASIER to install integrate commission diagnose and maintain Want MORE PRODUCTIVITY at the LEAST TOTAL COST to own Call Hardy to discover how Today 9440 Carroll Park Drive San Diego CA 92121 Te...

Reviews: