4.
Operation
The rotisserie cannot be operated during a power failure. In the event of a prolonged power
failure, do not attempt to operate the rotisserie. Turn off the red main ON/OFF switch and close
the gas valve. When power has been restored, open the gas valve, pull out the red main
ON/OFF switch and resume normal operation.
References will be made to an IDLE MODE in the next few sections that relate to rotisserie operation.
When in IDLE MODE, the controller displays
“PREHEAT OR CLEAN”
.
Morning Startup
ALWAYS TURN VENTILATION SYSTEM ON BEFORE STARTING ROTISSERIE. IT IS REQUIRED
TO REMOVE COMBUSTION BY-PRODUCTS AND GREASE-LADEN AIR.
4.1.1
Starting the Rotisserie
1. With power connected to the rotisserie, turn on the
Inferno GC by pulling out the red main ON/OFF switch
shown in Figure 3-3.
2. Make sure the main drain valve handle is set to
COOK
as shown in Figure 4-1.
3. Make sure the gas valve to the rotisserie is opened.
4. Follow any special instructions scrolling on the display, if
applicable.
5. Clean the strainers and turn on the ventilation hoods.
6. Once these conditions have been filled, select
PREHEAT
to ignite and the oven will begin the
preheat cycle.
Figure 4-1
If the red lamp is flashing indicating the burner did not light, press & hold STOP
to cancel.
Wait 5 minutes and try again.
See the safety lockout section of the troubleshooting chapter on pg 17.
4.1.2
Grease Collection
Hardt offers an optional Heated Grease Collection Reservoir
that is used to facilitate the collection and disposal of grease
from the rotisserie. If no reservoir is obtained from Hardt,
alternate methods of grease collection and disposal are
required.
If the optional Heated Grease Collection Reservoir from
Hardt is being used:
1. Ensure that the grease collection reservoir is clean and
fully drained.
2. Verify that the collection reservoir is properly positioned
under the grease drain from each rotisserie (Figure 4-2)
3. Plug in the grease collection reservoir.
Figure 4-2
If an alternative grease management system is in use, follow the instructions for daily care supplied by the
manufacturer of that system.
ENSURE DRAINS ARE
ALIGNED WITH
COLLECTION BASINS