5 - Operation
5.11
In the following diagrams handle positions for different options are described.
1
2
3
4
5
If a spraying job has been interrupted for a while, severe sedimenta-
tion can occur depending on chemicals being used. When re-star-
ting spray job, it might be necessary to agitate sedimented material
first.
1. Make sure the control unit is switched off.
2. Turn the bottom Suction Manifold valve handle towards “Suction
from main tank”. Turn the top Pressure Manifold valve handle
towards “Spray” and the bottom Pressure Manifold valve towards
“Agitation”.
3. Engage pump and set to operating r.p.m. (540 r.p.m.).
4. Agitation will start and should be continued for at least 10 minu-
tes.
5. Once the chemicals are mixed, spraying can resume.