4 - Sprayer setup
43
Electrical Connections
Power supply
Power requirement is 12V DC. Always note polarity! For proper function
of the electric equipment, the wires must have the following
recommended cross sectional areas and correct fuses to ensure a
sufficient power supply. The supplied power connectors follow the
standard of most newer tractors. If using a tractor with another power
connector, it is necessary to disassemble the connector and fit it to the
existing tractor connector.
The number and kind of connectors can vary on a specific sprayer,
depending on its equipment.
Control units
Find a suitable place in the tractor’s cabin to secure the control units
from movement. Best recommended placement is to the right of the
driver seat. The supplied bracket will fit most tractors. Threaded
mounting holes may be hidden behind front corner cover.
LIGHTER CONNECTOR
Spray control unit requires:
Wire 2.5 mm², Fuse 10 Amp
Hydraulic control unit requires:
Wire 4.0 mm², Fuse 16 Amp
7 POLE TRAFFIC LIGHT CONNECTOR
JOBCOM CONNECTOR
The unit requires:
Wire 6.0 mm², Fuse 25 Amp
WORKING LIGHT CONNECTOR
The unit requires:
Wire 10.0 mm², Fuse 30 Amp
ISO POWER CONNECTOR
Summary of Contents for NAVIGATOR 3000
Page 2: ......
Page 4: ......
Page 10: ...1 Welcome 8 ...
Page 36: ...3 Description 34 ...
Page 52: ...4 Sprayer setup 50 ...
Page 82: ...5 Operation 80 ...
Page 104: ...7 Fault finding 102 ...
Page 116: ...8 Technical specifications 114 ...
Page 121: ......