3 - Description
24
Filters
An EasyClean suction filter is fitted in the working zone.
A Cyclone pressure filter is fitted to the sprayer’s right side just in front of the ChemLocker. It has a built-in self-cleaning
function.
In-line pressure filters can be fitted at each boom section as an option.
All filters should always be in use and their function checked regularly. Pay attention to the correct combination of filter and
mesh size (see “Filters and nozzles” on page 106).
EasyClean Filter
To ensure proper function of filter and its built-in valve, the filter must be
opened at least once every month. A label on the lid also designates this.
•
To open filter, turn it counterclockwise and pull it up as shown in
picture.
•
Pull out the two locks (A) to remove filter element from the lid.
An EasyClean clogging indicator is located beside the spray pressure
gauge on the platform:
Clogging indicator color
Filter status
Green indicator.
No cleaning necessary.
Yellow indicator.
It is possible to finish an ongoing spraying job and
then clean the filter afterwards.
Red indicator.
Clean the EasyClean Filter immediately, as the filter is
clogged.
Summary of Contents for NAVIGATOR 3000
Page 2: ......
Page 4: ......
Page 10: ...1 Welcome 8 ...
Page 36: ...3 Description 34 ...
Page 52: ...4 Sprayer setup 50 ...
Page 82: ...5 Operation 80 ...
Page 104: ...7 Fault finding 102 ...
Page 116: ...8 Technical specifications 114 ...
Page 121: ......