3 - Description
18
TurboFiller (optional)
TurboFiller suction valve
The valve is used simultaneously with the TurboFiller. The valve has 2
settings: Continuously open or spring loaded normally closed. Open the
valve when chemicals are to be filled into the TurboFiller.
TurboDeflector valve
This TurboDeflector valve activates the Vortex flushing of the TurboFiller.
Lift the lever to lock it in open position for continuous liquid rotation in
the hopper.
Chemical Container Rinsing lever
The upper lever is used for two purposes:
When the TurboFiller lid is open: For rinsing empty containers. Place the
container over the rotating flushing nozzle in the middle of the
TurboFiller to rinse the inside of the container.
When the TurboFiller lid is closed: Use the Chemical Container Rinsing
lever to rinse the hopper when the filling of chemicals is completed.
€
DANGER! Do not press the lever unless the multi-hole nozzle is covered by a container as spray liquid may otherwise
hit the operator.
Filling chemicals without TurboDeflection
Start TurboDeflector
Chemical Container Rinsing
Summary of Contents for MASTER PRO VHH