5 - Operation
76
Liquid System
Filling/Washing Location Requirements
When filling the sprayer with chemicals and water, it is important to avoid spot contamination by spraying chemicals in
order to protect the subsoil water resources.
At a Dedicated Filling Site
If the sprayer is always filled on the same location, a special filling/washing location should be established. This should have
a hard, liquid-impenetrable surface (e.g. concrete) securing against seepage, together with edges securing against run-off
to the surrounding areas. The location should be drained to an adequate receptacle (e.g. slurry tank or similar).
Any spillage or washings should be retained and diluted in order to be distributed in a larger area. This is to ensure minimal
environmental impact and avoid build-up of larger chemical concentrations at one spot.
If no other requirements of distances exist, the following general recommendation of distance can be used. Filling location
must be no closer than:
1.
50 yards (meters) from public water supplies for drinking purposes, and
2.
25 yards (meters) from non-public water supplies for drinking purposes and from treatment sumps and cesspools of
drainage systems, and
3.
50 yards (meters) from surface water (watercourses, lakes and coastal waters) and from nature reserves.
In the Field
Alternatively the sprayer can be filled in the field, where the spraying is to take place. If so, choose a different location for
each refilling.
If no other requirements of distances exist, the filling should not take place closer than:
1.
300 yards (meters) from public or non-public water supplies for drinking purposes, and
2.
50 yards (meters) from surface water (watercourses, lakes and coastal waters), treatment sumps, cesspools of drainage
systems, and nature reserves.
ATTENTION! Legislation and requirements vary. Always follow local legislation in force at any time.
ATTENTION! It is the responsibility of the sprayer owner/operator to comply with all relevant legislation. HARDI®
cannot undertake any responsibilities for incorrect operation and use.
Filling of Water
The tank should normally be filled 1/3 with water before adding
chemicals. Always follow the instructions given on the chemical
container!
±
WARNING! If the sprayer is put aside with liquid in the main tank,
all manifold valves must be closed.
Summary of Contents for COMMANDER 4500
Page 2: ......
Page 4: ......
Page 10: ...Table of Contents 8...
Page 12: ...1 Welcome 10...
Page 48: ...3 Description 46...
Page 96: ...5 Operation 94...
Page 99: ...6 Maintenance 97 Lubrication and Oiling Plan Boom Width 80 100 10 10 10 C 500 C 50 C 50 10...
Page 100: ...6 Maintenance 98 Lubrication and Oiling Plan Boom Width 120 10 C 500 C 50 10...
Page 129: ...6 Maintenance 127 At the same time adjust the two stop bolts to align the boom sections...
Page 142: ...6 Maintenance 140...
Page 162: ...8 Technical Specifications 160...
Page 168: ...Index 166...
Page 169: ......