5 - Operation
84
Agitation Before Resuming a Spray Job
If a spray job has been interrupted for a while, severe sedimentation may
occur depending on the chemicals being used. Before resuming the
spray job, it might be necessary to agitate sedimented material first.
1.
Turn the handle at the suction valve to “Suction from main tank”.
Turn the pressure SmartValve handle to an unused function and
turn the Agitation valve to “Agitation”.
2.
Engage the pump and set P.T.O. revolutions to 1000 rpm.
3.
Agitation will start and should be continued for at least 10 minutes.
4.
Once the chemicals are mixed, spraying can resume. Turn pressure SmartValve to “Spraying” and start spraying.
TurboFiller Rinsing
÷
NOTE! It is important to use clean water from the rinsing tank.
Rinse the TurboFiller and chemical containers as follows:
Cleaning Empty Containers - TurboFiller Lid is Open
1.
Put container over the rotating flushing nozzle in the middle of the
TurboFiller so that the nozzle is inside the container.
2.
Simultaneously press the Chemical Container Cleaning lever and
the TurboFiller suction valve. This rinses the chemical container
with the flushing nozzle while the rinsing liquid is emptied out of the TurboFiller.
TurboFiller Rinsing - TurboFiller Lid is Closed
1.
Close TurboFiller lid.
2.
Turn the suction SmartValve to “Rinsing tank”.
3.
Open the Turbo Deflector Valve
for 1 minute to get plenty of clean water through the hoses.
4.
Simultaneously press the Chemical Container Cleaning lever and the TurboFiller suction valve. This rinses the hopper
with the flushing nozzle while the rinsing liquid is emptied out of the TurboFiller.
5.
Rinse the hopper for 30-40 seconds.
6.
Open the lid to inspect if the TurboFiller is empty. If not, close the lid again and press the TurboFiller suction valve, until
the TurboFiller is empty.
7.
After the last flushing, the TurboFiller suction valve must be open for at least 20 seconds after the rinse water is no
longer visible in the hopper in order to completely empty the transfer hoses into the main tank.
ATTENTION! The TurboFiller needs to be cleaned thoroughly after finishing spraying. This is to ensure that it is clean
before spraying other crops that may be sensitive to the chemicals just used. See the section “Cleaning” on page 86
for details.
Summary of Contents for COMMANDER 4500
Page 2: ......
Page 4: ......
Page 10: ...Table of Contents 8...
Page 12: ...1 Welcome 10...
Page 48: ...3 Description 46...
Page 96: ...5 Operation 94...
Page 99: ...6 Maintenance 97 Lubrication and Oiling Plan Boom Width 80 100 10 10 10 C 500 C 50 C 50 10...
Page 100: ...6 Maintenance 98 Lubrication and Oiling Plan Boom Width 120 10 C 500 C 50 10...
Page 129: ...6 Maintenance 127 At the same time adjust the two stop bolts to align the boom sections...
Page 142: ...6 Maintenance 140...
Page 162: ...8 Technical Specifications 160...
Page 168: ...Index 166...
Page 169: ......