5 - Operation
47
Filling liquid chemicals by HARDI TurboFiller (optional)
1.
Fill the main tank at least 1/3 with water (unless otherwise stated on
the chemical container label).
2.
Turn the Manifold valve towards towards TurboFiller.
3.
Set the fan gear lever to neutral position, engage the pump and set
P.T.O. at 540 r/min.
4.
Open TurboFiller lid. Measure the correct quantity of chemical and
fill it into the hopper.
5.
Engage the hopper transfer device by opening the TurboFiller suc-
tion valve and the chemical is being transferred to the main tank.
Engage the flushing devise to flush the hopper. If powder chemicals are
filled the flushing device must be open before pouring the powder into
the hopper.
6.
If the chemical container is empty, it can be rinsed by the Chemical
Container Cleaning device. Place the container over the multi-hole
nozzle and push the upper lever to the left of the TurboFiller.
7.
Close TurboFiller suction valve when the hopper has been rinsed.
8.
Close the TurboFiller lid.
€
DANGER! Always wear face shield and other appropriate personal
safety equipment when filling chemicals.
±
ATTENTION! The scale in the hopper can only be used if the sprayer is parked on level ground! It is recommended to
use a measuring jug for best accuracy.
€
DANGER! In order to avoid spray liquid hitting the operator, do not press lever unless the multi-hole nozzle is covered
by a container as spray liquid may otherwise hit the operator.
±
ATTENTION! Rinsing device uses spray liquid to rinse containers for concentrated chemicals. Always rinse the che-
mical containers with clean water several times until they are clean before disposal.
±
ATTENTION! The hopper rinsing device is using spray liquid for rinsing the hopper for concentrated chemical!
Cleaning the TurboFiller must always be done when the spray job is ended and together with the entire sprayer - a
cleaning after the last filling and before spraying the last tankful does not ensure a clean TurboFiller!
9.
Disconnect the pressure to the TuboFiller, keep agitation activated to ensure homogene concentration.