Fault
Probable cause
Control / remedy
EC Operating unit
Operating unit not
Blown fuse(s).
Check mechanical function of microswitches.
functioning
Use cleaning/lubricating agent if the switch
does not operate freely.
Check motor. 450-500 milli-Amperes max.
Change motor, if over.
Wrong polarity.
Brown - pos. (+). Blue - neg. (-).
Valves not closing properly.
Check valve seals for obstructions.
Check microswitch plate position. Loosen
screws holding plate a
1
/
2
turn.
No power.
Wrong polarity. Check that brown is pos. (+),
Blue is neg. (-).
Check print plate for dry solders or loose
connections.
D.A.H. Hydraulic system
No boom movements
Insufficient oil pressure
Check oil pressure - min. 130 bar, max. 150 bar.
when activated
Check hydraulic oil level
Insufficient oil supply.
Check hydraulic oil level.
Blown fuse.
Check / replace fuse in junction box.
Bad / corroded electrical connections
Check / clean connections, etc.
Insufficient power supply.
Voltage on activated solenoid valve must be
more than 8 Volts. Use wires of at least 4 mm
2
for power supply.
Defect relay / diodes in junction box.
Check relays, diodes and soldering at PCB in
junction box
Wrong polarity.
Check polarity. White pos. (
+
) Blue neg. (
-
).
Individual ram
Clogged restrictor
Dismantle and clean restrictor
does not move
Summary of Contents for ALPHA 2000
Page 5: ......
Page 6: ......
Page 7: ......
Page 9: ......
Page 16: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 36: ......
Page 37: ......
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 51: ......
Page 52: ...52 ALPHA Notes...