Page 7
For technical questions, please call 1-888-866-5797.
Item 63320
Operation
After reading these instructions, consider the following points before starting the pump:
1. Verify that the discharge pipe is properly connected.
2. Verify that the electrical connection
is 120 VAC, 60 Hz.
3. Verify that the electrical socket is GFCI
protected and in good condition. Test
GFCI protected outlet before use.
4. Verify that water and moisture cannot
get near the power supply socket.
5. Verify that the pump is installed so
as to prevent running dry.
6. To start the pump:
a. Open the valve on outlet side of the Y-fitting.
b. Make sure your hands are dry.
c. Plug in the pump.
d. Turn on the Power Switch (I).
e. Close the valve on the priming side of the Y-fitting.
NOTICE: Do not run the Pump Dry!
Turn off the Pump IMMEDIATELY if water
stops coming out the Outlet.
7. If you operate the Pump and no water comes
out, shut the Pump off IMMEDIATELY. Check the
pipes for air-tightness. Check also that the bottom
of the Inlet pipe is underneath the surface of the
water and a foot valve is properly installed.
8. After the pump is running properly, the priming
hose and bucket can be disconnected.
9. When finished using the pump, turn the Power
Switch off (O), then unplug the Power Cord. Follow
procedures for Storage explained on the next page.