background image

Visit our website at: http://www.harborfreight.com

Email our technical support at: [email protected]

Do not return this 
pump to the store. 
Call 1-844-416-9141

Owner’s Manual & Safety Instructions

Save This Manual

 

Keep this manual for the safety warnings and precautions, assembly, 

operating, inspection, maintenance and cleaning procedures.  Write the product’s serial number in the 
back of the manual near the assembly diagram (or month and year of purchase if product has no number). 
Keep this manual and the receipt in a safe and dry place for future reference. 

21b

When unpacking, make sure that the product is intact 

and undamaged.  If any parts are missing or broken, 

please call 1-888-866-5797 as soon as possible.

Copyright

©

 2020 by Harbor Freight Tools

®

.  All rights reserved.  

No portion of this manual or any artwork contained herein may be reproduced in 

any shape or form without the express written consent of Harbor Freight Tools.  

Diagrams within this manual may not be drawn proportionally.  Due to continuing 

improvements, actual product may differ slightly from the product described herein.  

Tools required for assembly and service may not be included.

Read this material before using this product. 
Failure to do so can result in serious injury. 
SAVE THIS MANUAL.

Summary of Contents for Drummond 63320

Page 1: ...and dry place for future reference 21b When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2020 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Too...

Page 2: ...em 63320 Before start up note the following The pump must be connected to a GFCI protected plug which has been installed according to regulations The plug must have a supply voltage of 120 VAC at 60 Hz CAUTION This pump has been evaluated for use with water only ...

Page 3: ...The pump must be protected from frost 7 The pump must be protected from running dry 8 Access by children should also be prevented with appropriate measures 9 To prevent death from electric shock pump must be connected only to a GFCI protected outlet 10 Do not use an extension cord with this item 11 People with pacemakers should consult their physician s before use Electromagnetic fields in close p...

Page 4: ... technical questions please call 1 888 866 5797 Item 63320 Specifications Electrical Rating 120VAC 60Hz 10A Power Cord Length 6 Maximum Flow 0 1075 GPH Maximum Head lift 0 Flow 70 PSIG Discharge Port Ǝ 137 7KUHDG ...

Page 5: ...g according to regulations The pump is designed to be connected to 120 VAC 60 Hz GFCI protected socket 2 Make sure that the socket is sufficiently secured and is in excellent condition 3 When the plug is inserted into the socket the pump will be on standby 4 WARNING To prevent death from electric shock pump must be connected only to a GFCI protected outlet WARNING TO PREVENT SERIOUS INJURY If the ...

Page 6: ... Install a foot valve and filter sold separately at the bottom of the inlet Pump Bucket full of clean water Prim ing Hose Prim ing Hose Outlet Pipe Outlet Pipe Inlet Pipe Inlet Pipe Foot Foot Valve Valve Y fitting Y fitting with one valve with one valve for each outlet for each outlet Figure C Pump Position 7 Attach the outlet connection to the Outlet A Y fitting with dual valves sold separately i...

Page 7: ...ump a Open the valve on outlet side of the Y fitting b Make sure your hands are dry c Plug in the pump d Turn on the Power Switch I e Close the valve on the priming side of the Y fitting NOTICE Do not run the Pump Dry Turn off the Pump IMMEDIATELY if water stops coming out the Outlet 7 If you operate the Pump and no water comes out shut the Pump off IMMEDIATELY Check the pipes for air tightness Ch...

Page 8: ...and debris from the bottom of the basin 2 Clean sludge debris from inlet screen 3 Make sure discharge pipe is free from leaks 4 Make sure check valve is functioning properly 5 Manually operate flow switch to determine that pump turns on off as intended Long Term Storage 1 Drain Pump Body Disconnect both suction and outlet lines then tip pump so that all water is drained from pump cavity 2 If the P...

Page 9: ... 1 Consult an electrician 2 OORZ ZDWHU OHYHO WR ULVH DERYH Ǝ or move Pump to a lower location 3 Have a qualified service technician repair or replace 4 Check that cord is plugged in 5 Check power at outlet If outlet is unpowered turn off tool and check circuit breaker If breaker is tripped make sure circuit is right capacity for tool and circuit has no other loads 6 Have fuse replaced by a qualifi...

Page 10: ...Washer 2 5 Spring Washer 2 6 Foot 2 7 Handle 1 8 Screw M6x12 8 9 O Ring 8 2 X 1 9 2 10 Drain Plug 2 11 Dust Proof 2 12 Pump Body 1 13 O Ring 26 3X2 2 1 14 Diffuser 1 15 Venturi Tube 1 16 nut 1 17 Spring Washer 1 18 Flat Washer 1 19 Impeller 1 20 Mechanical Seal 1 21 Bracket Cover 1 22 Waterproof Gland 1 23 O Ring 163X3 55 1 24 Pump Support 1 25 Ball Bearing 2 26 Shaft Key 1 27 Rotor 1 28 Stator 1 ...

Page 11: ...Page 11 For technical questions please call 1 888 866 5797 Item 63320 Assembly Diagram ...

Page 12: ...damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchand...