Make sure your extension cord is properly wired and in good electrical condition.
Always replace a damaged extension cord or have it repaired by a qualified electri-
cian before using it.
Protect your extension cords from sharp objects, excessive heat, and damp or wet
areas.
rECOMMENDED MINIMUM WIrE GAUGE fOr ExTENSION COrDS*
(120 Or 240 VOLT)
NAMEPLATE
AMPErES
(at full load)
ExTENSION COrD LENGTH
25 feet
50 feet
75 feet
100 feet 150 feet
0 – 2.0
18
18
18
18
16
2.1 – 3.4
18
18
18
16
14
3.5 – 5.0
18
18
16
14
12
5.1 – 7.0
18
16
14
12
12
7.1 – 12.0
18
14
12
10
-
12.1 – 16.0
14
12
10
-
-
16.1 – 20.0
12
10
-
-
-
TABLE A
* Based on limiting the line voltage drop to five volts at 150% of the rated amperes.