16
Lowes.com/harborbreeze
TROUBLESHOOTING
1. Power turned off, fuse blown or
circuit breaker tripped.
1. Turn power on, replace fuse or reset breaker.
2a. Turn power off and loosen canopy; check all
connections according to section WIRING
INSTRUCTIONS on page 10.
2b. Check the plug connection in the switch housing.
3. Motor reversing switch not
engaged.
3. Push switch firmly right or left. Fan will not operate
when switch is in the middle.
4. Pull chain switch not "on".
4. Pull switch chain.
1. Wrong wire connection.
1a. Refer to Step 1, page 10 to ensure all wire
connections were done correctly.
2. Bulb is burned out.
2b. Replace the bulbs.
Light does not work
Fan does not start
2. Loose wire connections or wrong
connections.
PROBLEM
PROBABLE CAUSE
CORRECTIVE ACTION