-SJ -29
No. Display
Setting
Difult is underlined
Contents
2 Tightness
level
‑ (Loose)
□ (Normal)
+ (Tight)
The machine adjusts thread tightness level by controlling the timing of frame
move.
By default it is set to "
Normal
".
3 TRD. break
back
Yes
No
On thread breaks, this causes sewing position & frame to move backwards by
several stitches before the detected break before stopping.
5 Width data
limit
1 - 13mm
(13=12.7)
When stitch length exceeds this length, the machine divides it by this jump
length and creates multiple movements. Width data limit becomes 12.7mm only
when setting value is set to 13.
Please use a smaller number when you use thick and heavy material.
6 Quick start
mode
Yes.............
No...............
If you set to "No", the machine will increase speed slowly. Please select "No."
when you have a problem with skipped stitches on the beginning stitch after
thread trim.
• The machine sews up to 3 stitches slowly after thread cut.
• The machine sews up to 5 stitches slowly after thread cut.
7 Auto thread
cut
Yes
No
This performs automatic thread cut after color change and stop.
8 Cut at jump
data
1 ~ 8 (3)......
0..................
When a set number of continuous jumps exists in pattern data, the machine
cuts threads before jumping.
• Machine trims the thread on setting number of constant jump.
• Does not trim.
9 Cut at null
jump
Yes.............
No...............
This sets thread cuts before null jumps (isolated jumps with no net movement)
• Does trim on empty jump data.
• Does not trim on empty jump data.
10 CHG. always
cut
Yes.............
No...............
Forces a trim at every color change.
• Always thread trim before color change.
• If data does not have trim function at color change point, machine does not
trim.
11 Length of
TRD.cut
Max.
Long
Normal
Short
Min.
Needle........
The machine cuts upper threads to a longer length.
• The upper threads of each needle will be cut off by registered length.
15-3
13 Width data
all
-1.0 ~ 1.0mm
0.0mm.......
This is to alter the widths of all satin stitches for all the designs in the memory.
• Adjust satin stitch width by selected amount.
• Does not adjust width.
14 TRD. break
detect
Quick 3
~
~
Norma
~
~
Slow 3
Off
Needle........
Sensitivity selection of the thread break detect sensor.
By default it is set to "Normal".
• You can set sensitivity of thread break detection needle by needle.
15-4
15 Convert cap
Yes
No
When you install the cap drive frame on the machine, the machine will convert
(rotate) your design automatically.
16 Revers frame
move
Yes
No
Frame will be moved in the opposite direction of the arrow key.
17 STR.Auto
Position
Yes
No
Machine remembers & returns to last sewn position after sewing interruption
even if operator has moved the frame after interrupt.
18 Embroidery
weight
Light
Middle
Heavy
This setting for heavy duty material depends by material weight.
Normally, please select "middle" or "Heavy" for Border frame.
Machine speed is decreased automatically, when you sellect "middle " or
"heavy".
15-1
MACHINE SETTINGS
5_1 O512
Before embroidering, check the basic settings of the machine.
The rest of the settings can be left at default values (as indicated by underline below).