7.3 Functions
Screen
5.7 Inch Color LCD and Interface with Touch Panel
Pattern
Max 100 , Available to operate each channel's pattern
Segment
Max 2,400 ( Max 100 per segment)
Waiting Mode
Setup per pattern and setup of using or not using per segment
Repetition & Connection
Available to use Pattern Repetition and Section Repeat Loof Setup
(Max. 20) Free connecting operation among patterns is available
PID Group
Each channel 4 Zones, Selectable between manual or automatic
Control Method
Heating control or Heating/Cooling control in each channel. PID or
ON/OFF control
Auto Tuning
Optimal PID GAIN is automatically calculated according to Set Value.
It could be operated by each channel
Proportional Band
0.0 ~ 1000.0 ℃ ( If "0" = On/Off control, Not "0" = PID control)
Integral Time
0 ~ 6000 sec ( "0" = No Integral Calculation)
Differential Time
0 ~ 6000 sec ( "0" = No Differential Calculation)
ON/OFF control
Available to select Dead zone 0.1 ~ 1000.0 ℃
Event Log
Max 40 Event Logs could be saved depend on various situations
LCD protection
Back light will be off according to designated time of not using touch panel
Password
Password is available to prevent other people from changing system setup
Protection of Over-
Integral and Differential
ARW Zone setup ( 50 ~ 200 % of proportional band)
Fuzzy Function
Control overshoot
RAMP
Available to select SV changing ratio in case of fixing operation
Restrict MV changing ratio Function to control sudden change of MV
Alarm Setup
4 points, High, Low, Deviation etc. 20 kinds
Inner Signal
8 points, object, range and delayed time setup are available
Time Signal
8 points when program mode operation
Graph Function
PV, SV of each channel could be display by graph
Fixing Operation Hour
Available to set fixing operation hour up
Reservation Operation
Fuction
Available to use reservation operation time by using built in timer.
User Logo Display
User logo could be shown for 3 sec after power on. Download through
communication port
Screen Capture
Upload is available through communication port
Language
Korean and English
Contact Input
RUN/STOP, STEP, HOLD and Error Input
(Stop operation, Delayed/ setup is available)
Contact Output
Output of various signals
Storage in Power Failure
Various setting and operation information memory
Return from Power Failure STOP / COLD / HOT return when power failure is restored