22
-
68
Hanskamp AgroTech B.V. (the Netherlands)
www.hanskamp.nl/en
Spider
EN
Voercomputer—Feeding computer—Fütterungscomputer—ordinateur d
’
alimentation
Index
Explanation address:
Normally this will be set as address
“01”.
Are there more PCB
’
s, then make sure they all get an
other address.
Spider PCB:
Give the SpiderPCB a name, e.g. "SpiderServer".
Select a feeding station:
Select the feeding station you want to configure.
Description:
Feeding station name, e.g. "Feedstation 1".
Antenna no.:
The exit number on the Spider PCB which the antenna is connected to. The checkmark indicates
whether the HDX reader is activated.
Closing gate no.:
The exit number which the closing gate is connected to; these can be found in blocks of 3 at the
bottom of the Spider PCB.
Test:
Test the correct operation of the closing gate.
Auto:
If present, the closing gate will be automatically actuated.
On:
The closing gate will be actuated and will close.
Off:
The closing gate will remain open.
Disabled:
The closing gate is disabled.
No closing gate:
click "
Select
".
Front gate no.:
The exit number which the T'port is connected to.
Note: this only applies to the FeedStation walk
-
through.
Test:
Test the correct operation of the front gate.
Auto:
If present, the front gate will be automatically actuated.
On:
The front gate will be actuated and will close.
Off:
The front gate will remain open.
Disabled:
The front gate is disabled.
No front gate:
click "
Select
".
Detection no.:
The number on the Spider PCB which the sensor is connected to; these are the bottom ports on the
Spider PCB. Note: Only in combination with T'port.
No detection:
click "
Select
".
Dispenser number:
Specify which exit on the SpiderPCB the motor is cpnnected to.
Feed type—Silo:
Specify which feed type and silo correspond to this dispenser.
Motor type:
Specify which motor the dispenser has. For manual settings, see chapter 7.5.4.
Note: Dispenser no. "FEEDER1" is connected to exit "FEEDER1" on the Spider PCB. Ensure that a feeder is
connected to the number entered. Press test to check this.
Complete these steps for all feeding stations and click "
Save
".