SPECIFICATIONS
NOTE:
Failure to meet minimum water requirements may cause the Elements
to foul and void the manufacturer’s warranty.
Operating Limits
Maximum Feed Water Temperature °F (°C)
90/32
Maximum Operating Pressure psi (bar)
200/13
.8
Minimum Feed Water Temperature °F (°C)
35/1.67 Maximum Input Free Chlorine ppm
4
Maximum Ambient Air Temperature °F (°C)
120/48.9 Maximum TDS ppm
750
Minimum Ambient Air Temperature °F (°C)
35/1.67 Maximum Hardness gpg
30
Maximum Feed Pressure psi (bar)
80/5.52 Maximum Feed Water pH (Standard)
9
Minimum Feed Pressure psi (bar)
30/2.06 Minimum Feed Water pH (Standard)
6
Maximum Feed Water Total Iron
3 ppm
NOTE:
Higher feed TDS
and/or lower temperatures will reduce the system’s
water production output.
NOTE:
For optimal performance if your system is on a well, make sure the feed
water pressure switch is set to turn on at a minimum of 45 psi for best
performance.
NOTE:
For feed pressure that exceeds 80 psi, a pressure reducing valve (PRV)
must be installed.
•
See Performance Data Sheet (
https://hanspremiumwater.com/faqs/
) for further information.
•
This system conforms to LEC 2006 for specific performance claims as verified and substantiated by test
data.
•
This Reverse Osmosis system contains replaceable treatment components critical for effective
performance. It is the users responsibility to heed all alerts and warning from the system concerning filter,
calcite cartridge and element replacement from the on board display and the mobile app. The
manufacturer also recommends that the user periodically test the product water to verify the system is
performing correctly.
•
This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3
mg/L nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water
supplies with a pressure of 210 kPa (50 psig) or greater.