Important!
The fitting must be installed, flushed
and tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the sink.
3. Slip the plastic washer, the slide washer, the metall
washer and collar over the hoses and threaded
base and tighten the collar nut by hand. If there
is not enough space, please use only the slide
washer and the metal washer without the plastic
washer.
4. Tighten screws.
5. Connect the supply pipes to the isolation valves;
cold right - hot left.
6. Connect the hose with hose nut, taper sleeve,
disc and washer.
7. Mount the hose weight - be careful by the max.
drawn out, otherwise the hose could be crack.
After the assembly!
8. Dismount the handspray and the filter.
9. Flush through the hose.
10. Clean the filter.
11. Mount the filter and the handspray
12. Re-connect down, handscrew (1 Nm).
Large differences in pressure between the hot and
cold water supply should be balanced.
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
The handspray can be drawn approx. 50 cm out of
the arm lining. The spray mode is changed to sho-
werspray by pressing the front button
on the top
of the sprayhead. By pressing the rear button
or
switching off the water, the spray mode changes to
aerated spray.
To retract the hose easily it is only possible when the
swivel arm is in the middle position.
English
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure: 0.15 - 0.5 MPa
Test pressure:
1.6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80° C
Recommended hot water temperature: 65° C
Rate of flow by 0.3 MPa aerated spray: 11 l/min
Rate of flow by 0.3 MPa shower spray: 12 l/min
Back flow and vacuum breaker
Hansgrohe single lever mixers can be used toge-
ther with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0.15 MPa.
To adjust the hot water limiter on single lever mixers,
please see page 14.
No adjustment is necessary when using a continuous
flow water heater.
Spare parts
(see page 3)
1
handle
14092000
1.1 screw cover
96338000
2
flange
96391000
3
nut
94194000
4
cartridge cpl.
92730000
5
hose
95048000
6
handspray
14893000
7
aerator cpl.
13955000
8
fixation cpl.
95049000
9
connection hose 900 mm
98696000