Assembly See Page 6
Fault
Cause
Remedy
Insufficient water
-Supply pressure inadequate
-Check water pressure (If a pump
has been installed check to see if
the pump is working).
-Filters are dirty (97367000)
-Clean filter in front of the mixer
and on the MTC-thermo cartridge
(97367000)
-Shower filter seal dirty
-Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
-Backflow preventers dirty or
leaking
-Clean backflow preventers,
exchange if necessary
Spout temperature does not cor-
respond with temperature set
-Thermostat has not been adjusted
-Adjust thermostat
-Hot water temperature too low
-Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
-thermo cartridge calcified
-Exchange thermo cartridge
Shower or spout dripping
-Dirt or sedimentation on valve seat,
shut-off unit damaged
-Clean or exchange shut-off unit