Dimensions
(see page 13)
Operation
(see page 11)
Maintenance
(see page 9)
• To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
• The mixer is equipped with non return
valves. The non return valves must be
checked regularly according to DIN EN
1717 in accordance with national or re-
gional regulations (at least once a year).
Adjustment
(see page 7)
After the installation, the output tempera-
ture of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
Safety Function
(see page 8)
The desired maximum temperature for exam-
ple max. 42º C can be pre-set thanks to the
safety function.
Do not use silicone containing acetic acid!
Symbol description
6
Safety Notes
6
Gloves should be worn during installation to prevent
crushing and cutting injuries.
6
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The product is not designed to be used with steam
baths!
• The mixer must be installed, flushed and tested!
Assembly
(see page 6)
Pressure and permeability test
• The connections of the thermostatic mixer should be
tested regular after installation.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar ≈ 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Centre distance:
160 mm
Connections M 26x1,5:
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking water!
English
Assembly See Page 6
2 (16)