Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Regulator filter dirty
- Clean filters
- Shower filter seal dirty
- Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
- Backflow preventers dirty or
leaking
- Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not
possible
- Temperature regulator dirty or
calcified
- Clean temperature regulator,
exchange if necessary
- For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180º rotation
- Install function block turned through
180º
Safety stop button not operating
- Spring defective
- Button calcified
- Clean spring and/or button,
exchange if necessary
7
Summary of Contents for Axor Starck 10755000
Page 60: ...60 27 mm 1 2 3 4 Silicon 17 mm 6 5 24 mm 15 2 Nm ...
Page 61: ...61 11 8 2 mm 7 3 mm 4 1 Nm 2 1 10 9 ...
Page 62: ...62 4 3 1 2 6 1 2 5 2 mm 3 mm 3 mm 1 2 ...
Page 63: ...63 1 3 2 7 8 1 2 2 mm 1 2 2 mm 2 mm 1 2 ...
Page 64: ...64 2 3 4 1 1 2 3 6 5 SW 24 mm 3 mm 2 mm ...
Page 65: ...65 8 9 10 7 3 11 2 mm 3 mm 4 1 Nm SW 24 mm 15 2 Nm ...
Page 66: ...66 1 38 C 2 ...
Page 67: ...67 PA IX DVGW SVGW ACS WRAS MCA KIWA 10755000 X ...