6
6 6
Safety Notes
6
Gloves should be worn during installation to prevent
crushing and cutting injuries.
6
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
6
The hot and cold supplies must be of equal pressu-
res.
Installation Instructions
The fitting must be installed, flushed and tested after the
valid norms!
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,15 – 0,6MPa
Test pressure:
1,6MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Rate of flow by 0,3 MPa:
1 Consumer
approx. 44 l/min
2 Consumer
approx. 55 l/min
anti-pollution function
English
Assembly see page 60
Do not use silicone containing acetic acid!
Safety Function
(see page 62)
The desired maximum temperature for
example max. 42º C can be pre-set thanks
to the safety function.
Adjustment
(see page 63)
After the installation, the output temperature
of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
Symbol description
Maintenance
(see page 64)
• To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
• The mixer is equipped with non return
valves. The non return valves must be
checked regularly according to DIN
EN 1717 in accordance with national
or regional regulations (at least once a
year). At this time, please also check the
filter (A) situated on the BTC-thermoele-
ment (96633000). After assembling the
BTC-thermoelement, it is necessary to
check the water temperature at the take
off point as described under the headline
„adjustment“. Before the adjustment,
please check, if the warm water supply is
activated and the maximum temperature
of the warm water is available at the take
off point.
Operation
(see page 66)
Cleaning
see enclosed brochure.
Test certificate
(see page 67)
Dimensions
(see page 67)
Spare parts
(see page 68)
6
Summary of Contents for Axor Starck 10755000
Page 60: ...60 27 mm 1 2 3 4 Silicon 17 mm 6 5 24 mm 15 2 Nm ...
Page 61: ...61 11 8 2 mm 7 3 mm 4 1 Nm 2 1 10 9 ...
Page 62: ...62 4 3 1 2 6 1 2 5 2 mm 3 mm 3 mm 1 2 ...
Page 63: ...63 1 3 2 7 8 1 2 2 mm 1 2 2 mm 2 mm 1 2 ...
Page 64: ...64 2 3 4 1 1 2 3 6 5 SW 24 mm 3 mm 2 mm ...
Page 65: ...65 8 9 10 7 3 11 2 mm 3 mm 4 1 Nm SW 24 mm 15 2 Nm ...
Page 66: ...66 1 38 C 2 ...