Hanna Instruments HI9810342 Instruction Manual Download Page 5

5

GENE
rAL

 D

ESC
ri

PT

iON

 & 

iNTENDED

 U

SE

3.  GENERAL DESCRIPTION & INTENDED USE

HI9810342

 is a professional wireless pH tester, part of Hanna Instruments HALO2 family.

•  The integrated Bluetooth module allows the tester to be connected to a compatible smart device with the Hanna Lab App.

•  The tester has a compact, waterproof casing, and automatic pH calibration at up to three points, or four points when 

used with the Hanna Lab App.

•  Automatically compensated temperature readings are displayed on a large LCD.

•  Accurate and easy to use, the tester is designed to measure the pH during the milk production process.

Operating Modes

The 

HI9810342

 can be used as a stand-alone pH tester or connected to the Hanna Lab App.

The Hanna Lab App turns a compatible smart device into a full-featured pH meter. Features include: electrode condition, 

GLP with time-stamp, live-readings, mV resolution, manual temperature compensation, stability criteria, calibration reminder, 

pH (mV), and temperature alarms, tester ID, and data sharing.

Probe Features

The 

HI9810342

 features a non-porous 

glass body

 that is easy to clean and disinfect.

The 

conical tip

 allows for easy penetration into semisolids, ideal for milk and milk products like yogurt.

Specialized 

low temperature (LT)

 pH glass ensures fast stabilization and accurate results at lower temperatures.

The 

double junction

 design presents a silver-free electrolyte solution interacting with the sample, making the electrode 

less susceptible to clogging and guaranteeing a fast response and stable reading.
Built-in 

temperature sensor

 at the tip of the pH electrode allows for rapid determination of the sample temperature and 

a high-accuracy temperature reading.

4.  FUNCTIONAL DESCRIPTION & LCD DISPLAY

Front & Back view

HI9810342

Milk

pH T

est

er

LCD

ON/OFF

button

Conical tip

Open junction

Maximum immersion level

Recommended immersion

pH Probe

 

SN: XXXXXXXXX
Made in Romania

HI9810342

        

       2

 

1

    

0

4

-

0

1

-

0

A

6

8

7

0

9

2

21  :

CI    

40

B9

A

A 2    :

D I   

C C F   

s n i a t n

Co

R

Setup 

button

Battery cover

LCD display

&

!

#

œ.œ.œ.œ

88.8.8

7

6

5

10

9

8

1
2
3
4

1 Calibration indicator

2 Stability indicator

3 Battery percentage indicator

4 Battery icon

5 Bluetooth icon

6 Temperature compensation

7 Second LCD line

8 Temperature unit

9 First LCD line

10 Measurement unit

Summary of Contents for HI9810342

Page 1: ...INSTRUCTION MANUAL HI9810342 Wireless pH Tester for Milk with built in specialized electrode Foodcare...

Page 2: ...a Hanna Instruments product Please read this instruction manual carefully before using this instrument This manual will provide you with the necessary information for correct use of this instrument a...

Page 3: ...ffer Set 6 pH Resolution 6 Bluetooth Wireless Mode 6 Bluetooth Pairing 7 Date Time 7 7 Bluetooth 7 8 Hanna Lab Application 7 Tag a Measurement 7 9 Calibration 7 Preparation Guidelines 7 Procedure 7 St...

Page 4: ...pH 0 01 or 0 1 pH mV 0 1 or 1 mV Temperature 0 1 C 0 1 F Accuracy pH 0 05 pH Temperature 0 5 C 0 9 F Calibration Up to three points or four points Automatic buffer recognition with Standard buffers H...

Page 5: ...342 features a non porous glass body that is easy to clean and disinfect The conical tip allows for easy penetration into semisolids ideal for milk and milk products like yogurt Specialized low temper...

Page 6: ...d battery type Dispose of old battery in accordance with local regulations 6 SETUP The Setup button is located inside the battery compartment After Setup configuration replace the cover Setup Menu Nav...

Page 7: ...able mode it will appear in the list of Available Devices Within the application tap Connect to pair the tester with the device All readings are transmitted directly to the application Tag a Measureme...

Page 8: ...e in the second buffer rinse beaker then in the second calibration buffer Wait until the measurement is stored and the stability indicator disappears 7 After the second point has been stored CAL SAVE...

Page 9: ...not in use add a few drops of storage solution to storage cap If storage solution is not available pH 4 01 or pH 7 01 buffer can be used Note Do not store the electrode in distilled or deionized water...

Page 10: ...d for the environment in which it is used Any variation introduced by the user to the supplied equipment may degrade the tester s performance For your and the tester s safety do not use or store it in...

Page 11: ...12208A 04 This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must a...

Page 12: ...World Headquarters Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA www hannainst com MAN9810342 Printed in ROMANIA...

Reviews: