13.  ACCESSORIES

Ordering Information Product Description

pH Buffer Solution

HI50016-02

pH 1.68 buffer solution, 20 mL sachet (25 pcs.)

HI70004P

pH 4.01 buffer solution, 20 mL sachet (25 pcs.)

HI70006P

pH 6.86 buffer solution, 20 mL sachet (25 pcs.)

HI70007P

pH 7.01 buffer solution, 20 mL sachet (25 pcs.)

HI70009P

pH 9.18 buffer solution, 20 mL sachet (25 pcs.)

HI70010P

pH 10.01 buffer solution, 20 mL sachet (25 pcs.)

HI77400P

pH 4.01 & 7.01 buffer solution, 20 mL sachet (10 pcs., 5 each)

HI770710P

pH 10.01 & 7.01 buffer solution, 20 mL sachet (10 pcs., 5 each)

Electrode Cleaning Solution

HI700601P

Electrode cleaning solution for general use, 20 mL sachet (25 pcs.)

HI700640P

Cleaning solution for milk deposits, 20 mL sachet (25 pcs.)

HI700641P

Cleaning and disinfection solution for dairy products, 20 mL sachet (25 pcs.)

Electrode Storage Solution

HI70300L

Electrode storage solution, 500 mL

HI70300M

Electrode storage solution, 230 mL

HI70300S

Electrode storage solution, 30 mL dropper

HI9072

Electrode storage solution, 13 mL dropper

RECOMMENDATIONS FOR USERS

Before using this product, make sure it is entirely suitable for your specific application and for the environment in which it is 

used. Any variation introduced by the user to the supplied equipment may degrade the tester’s performance. For your and the 

tester’s safety do not use or store it in hazardous environments.

WARRANTY

HI9810342

 is warranted for a period of one year against defects in workmanship and materials when used for its intended 

purpose and maintained according to instructions. This warranty is limited to repair or replacement free of charge. Damage due 

to accidents, misuse, tampering, or lack of prescribed maintenance is not covered. If service is required, contact your local Hanna 

Instruments office. If under warranty, report the model number, date of purchase, serial number, and the nature of the problem. 

If the repair is not covered by the warranty, you will be notified of the charges incurred. If the tester is to be returned to Hanna 

Instruments, first obtain a Returned Goods Authorization (RGA) number from the Technical Service department and then send it 

with shipping costs prepaid. When shipping any product, make sure it is shipped back in compliance with shipping regulations, 

thoroughly cleaned and free of any chemicals, and is properly packaged for complete protection.

MAN9810342 10/21

Hanna Instruments reserves the right to modify the design, construction or appearance of its products without advance notice.

Summary of Contents for HI9810342

Page 1: ...INSTRUCTION MANUAL HI9810342 Wireless pH Tester for Milk with built in specialized electrode Foodcare...

Page 2: ...a Hanna Instruments product Please read this instruction manual carefully before using this instrument This manual will provide you with the necessary information for correct use of this instrument a...

Page 3: ...ffer Set 6 pH Resolution 6 Bluetooth Wireless Mode 6 Bluetooth Pairing 7 Date Time 7 7 Bluetooth 7 8 Hanna Lab Application 7 Tag a Measurement 7 9 Calibration 7 Preparation Guidelines 7 Procedure 7 St...

Page 4: ...pH 0 01 or 0 1 pH mV 0 1 or 1 mV Temperature 0 1 C 0 1 F Accuracy pH 0 05 pH Temperature 0 5 C 0 9 F Calibration Up to three points or four points Automatic buffer recognition with Standard buffers H...

Page 5: ...342 features a non porous glass body that is easy to clean and disinfect The conical tip allows for easy penetration into semisolids ideal for milk and milk products like yogurt Specialized low temper...

Page 6: ...d battery type Dispose of old battery in accordance with local regulations 6 SETUP The Setup button is located inside the battery compartment After Setup configuration replace the cover Setup Menu Nav...

Page 7: ...able mode it will appear in the list of Available Devices Within the application tap Connect to pair the tester with the device All readings are transmitted directly to the application Tag a Measureme...

Page 8: ...e in the second buffer rinse beaker then in the second calibration buffer Wait until the measurement is stored and the stability indicator disappears 7 After the second point has been stored CAL SAVE...

Page 9: ...not in use add a few drops of storage solution to storage cap If storage solution is not available pH 4 01 or pH 7 01 buffer can be used Note Do not store the electrode in distilled or deionized water...

Page 10: ...d for the environment in which it is used Any variation introduced by the user to the supplied equipment may degrade the tester s performance For your and the tester s safety do not use or store it in...

Page 11: ...12208A 04 This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must a...

Page 12: ...World Headquarters Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA www hannainst com MAN9810342 Printed in ROMANIA...

Reviews: