Hanna Instruments HI 84100 Instruction Manual Download Page 5

5

Range

0 to 400 ppm of SO

2

Resolution

1 ppm

Accuracy

5% of reading

Method

Ripper titrimetric method

Principle

Equivalence point redox titration

Sample volume

50 mL

ORP Electrode

HI 3148B

 (included)

Pump debit

0.5 mL/min

Stirring speed

1500 rpm

Environment

0 to 50 °C (32 to 122 °F); max 95% RH non-condensing

Power supply

220V/50Hz; 10VA

Dimensions

208 x 214 x 163 mm (8.2 x 8.4 x 6.4") (with beaker)

Weight

2200 g (77.6 oz.)

REQUIRED REAGENTS
Code

Description

Quantity/test

HI  84100-50

Titrant (for Free & Total SO

2

)

HI  84100-51

Alkaline Reagent (for Total SO

2

) 5  mL

HI  84100-52

Acid Reagent (for Total SO

2

)

5  mL

HI  84100-53

Acid Reagent (for Free SO

2

)

5  mL

HI  84100-54

Stabilizer (for Free & Total SO

2

) 1 packet

HI  84100-55

Standard (for Free & Total SO

2

) 50 mL

SPECIFICATIONS

16

PREPARATION PROCEDURE
Remove the protective cap of the ORP electrode (

HI 3148B

).

DO NOT BE ALARMED IF SALT DEPOSITS ARE PRESENT. This is normal with electrodes. They will

disappear when rinsed with water.
During transport, tiny bubbles of air may form inside the glass bulb affecting proper functioning of

the electrode. These bubbles can be removed by “shaking down” the electrode as you would do

with a glass thermometer.
If the bulb and/or junction is dry, soak the electrode in 

HI 70300

 Storage Solution for at least one hour.

If the filling solution (electrolyte) is more than 2½ cm (1”) below the fill hole, add 

HI 7082

 3.5M

KCl Electrolyte Solution.

ELECTRODE CONDITIONING & MAINTENANCE

FUSE REPLACEMENT

To change the fuse follow next steps:
• Disconnect the power cord from the rear panel of

the instrument.

• Pull out the fuse holder located near the power cord

connector.

• Replace the fuse with a similar one.
• Push the fuse holder with the fuse in the appropriate

place.

Summary of Contents for HI 84100

Page 1: ...851 9129 0 Fax 07851 9129 99 Greece Tel 210 823 5192 Fax 210 884 0210 Indonesia Tel 21 4584 2941 Fax 21 4584 2942 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malays...

Page 2: ...ACCESSORIES 18 WARRANTY 19 19 Hanna Instruments reserves the right to modify the design construction and appearance of its products without advance notice HI 84100 is warranted for two years against...

Page 3: ...ffective interface for the user By simply pressing the START STOP button the instrument will automatically make the titration up to the equivalence point The result is immediately displayed in conveni...

Page 4: ...ted by the human senses is about 2 0 ppm This is also the level which is needed for maximum protection of your wine This is particularly true in the case of sweet and most notably botrytised wines The...

Page 5: ...PREPARATION PROCEDURE Remove the protective cap of the ORP electrode HI 3148B DO NOT BE ALARMED IF SALT DEPOSITS ARE PRESENT This is normal with electrodes They will disappear when rinsed with water D...

Page 6: ...volume has to be precisely known 15 PUMP CALIBRATION PROCEDURE Warning The calibration of the pump must be performed each time the pump tube the reagent bottle or the pH electrode is changed It is rec...

Page 7: ...ng clockwise Immerse the ORP electrode approximately 2 cm 0 8 into the sample to be tested while paying attention to not touch the stir bar Insert the dosing tip in the appropriate holder place and pa...

Page 8: ...e paying attention to not touch the stir bar Insert the dosing tip in the appropriate holder place and pay attention to not be immersed into solution Press the START STOP button to start the titration...

Page 9: ...ed during testing to ensure best accuracy Purge the peristaltic pump to have fresh titrant when starting a new analysis or calibration Calibrate the peristaltic pump before performing an analysis Anal...

Page 10: ...urging mode message PUMP CALIBRATION MESSAGES 11 This error message appears when the sample concentration exceeds 400 ppm The used standard solution is wrong This error message appears when the input...

Reviews: