VERTICAL SURFACE MOUNTING
Once you have selected the best installation site, simply screw or
bolt the unit into a wall or mounting panel above the chemical
feed tank.
The 4 mounting screw holes on the pump will accommodate up to
a 5 mm (3/16") screw or bolt (remember to use heavy screws or
bolts to secure the system).
Be sure you do not over tighten and cause excessive stress on the
mounting holes.
ELECTRICAL CONNECTIONS
Note
: All cables must be according to local electrical codes.
For safety of the users, the pump has to be grounded.
The pump should be connected to a single phase power source.
Color coding for wires:
Blue - Live
Brown - Neutral
Yellow/Green - Ground (earth)
It is recommended that the system be connected to a power line/
leg equipped with a circuit breaker of 1 Amp.