Setting examples:
0~3599
= 0 second, the device will not wake up by itself.
3600~7199
= 3600seconds, the device will wake up every 3600 seconds.
Ⅷ
. Battery command
1. When sending Battery get command to the product, the product will report the current battery
power when it wakes up.
2. The battery report value 0xff will be reported to the associated node of group 1 when the
product is at a low voltage (the threshold value can be configured in Configuration, the default
value is less than 20% of the power).
Ⅸ
. Security features of Flood Sensor in Z-Wave network
The following is a list of supported command classes:
1.The node info frame supports:
COMMAND_CLASS_ZWAVEPLUS_INFO
V2
COMMAND_CLASS_SECURITY
V1
COMMAND_CLASS_SECURITY_2
V1
COMMAND_CLASS_TRANSPORT_SERVICE
V2
2.Security Command Supported Report Frame:
COMMAND_CLASS_VERSION
V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC
V2
COMMAND_CLASS_NOTIFICATION
V5
COMMAND_CLASS_ASSOCIATION_GRP_INFO
V1
COMMAND_CLASS_ASSOCIATION
V2
COMMAND_CLASS_BATTERY
V1
COMMAND_CLASS_WAKE_UP
V2
COMMAND_CLASS_POWERLEVEL
V1
COMMAND_CLASS_SENSOR_MULTILEVEL
V5
COMMAND_CLASS_CONFIGURATION
V1
COMMAND_CLASS_SUPERVISION
V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD
V3
COMMAND_CLASS_DEVICE_RESET_LOCALLY
V1
Ⅹ
. ADVANCED CONFIGURATION
Flood Sensor offers a wide variety of advanced configuration settings. Below parameters can be
accessed from main controllers configuration interface.
Parameter No.14 Enable/Disable BASIC SET command