Operating Manual

Serial No.

 

Micro  Centrifuge

Purchase Date

Place of purchase

Micro 12

Summary of Contents for Micro 12

Page 1: ...Operating Manual Serial No MicroCentrifuge Purchase Date Place of purchase Micro 12 ...

Page 2: ...www ihanil com 2 20 Copyrightⓒ 2017 Hanil Scientific Inc All rights reserved Contact Us If youhave any questions contactHanil ScientificInc orplace of purchase techsupport ihanil com info ihanil com ...

Page 3: ...Pulse function 13 5 Maintenance 14 6 Troubleshooting 15 7 Rotor and accessories 17 3 1 Packing inspection 8 3 3 Connect power 9 1 General Considerations 4 1 1 Safety 4 1 2 Transport Storage 4 1 3 Safety labe 5 1 4 Electric safety information 5 2 2 Delivery package 6 2 3 Specifications 7 3 4 Opening closing the lid 9 3 5 Loading and removal of the rotor 10 3 6 Loading tubes 11 5 1 Care instructions...

Page 4: ...ing 16 Please contact the place of purchase or Hanil Scientific Inc techsupport ihanil com info ihanil com for product repairs 1 2 Transport Storage 1 1 Safety Ambient temperature 5 35 Maximumrelativehumidity 30 85 Airpressure 500 1060hpa Followprecautions and all the safetyrequirements described on this usermanual toprevent any damages and failure of equipment andloss of lives Abnormal vibrationi...

Page 5: ... anything on the power cable 5 Do not block vents 6 If you have the following emergencies shut off the power supply and unplug the power cord from outlet and Do not open lid until rotor stops completely Rotation direction of the rotor contact your place of purchase or Hani lScientific Inc Unusualnoises or smell from the equipment Damage or wear of apower cord Breakdown of circuitbreaker fuse or sa...

Page 6: ... is cloesd Lid open switch Press thebutton to open to the lid Controller Keys and knobsfor operatingthe centrifuge Power socket Connection for powercord Power switch Switch forswitching the centrifuge on off Absorbent rubber Fix the device on thelaboratory bench Standardoffering Micro12 main body Rotor included A2 0 12 Powercable 300 500V 6A Usermanual Optional products see 7 Rotor and accessories...

Page 7: ...om max speed 8 sec Tube Capacity 1 5 2 0ml x 12 Power supply AC110 220V 50 60Hz Dimension W x D x H mm 190 x 202 x 129 Weight kg 1 5 RCF Table Rcf value was calculated based on the bottom of the rotor hole RPM A2 0 12 RPM A0 2 32 0 2ml 0 5ml 1 5 2 0ml 0 2 ml Inner line 0 2 ml Outer line 3 000 443 545 594 3 000 313 443 464 560 6 000 1 231 1 515 1 651 5 000 870 1 231 1 289 1 556 8 000 3 151 3 877 4 ...

Page 8: ...nclined place the shaft may be bent due to the weight of the rotor Good ventailation For air circulation and safety maintain a 30cm clearance envelope around the centrifuge while the rotor is spinning Constant temperature humidity Centrifuge equipped with the sensitive electronic software which is fragile with humidity and temperature Must avoid direct ray or heater and be put in the ambience of c...

Page 9: ...el attached to the device 1 Connect the power cable to the power socket on the right side of the product and plug the cord into the outlet 2 Switch the centrifuge on using the power switch on the right side of the device It is normal product to hear a beep when power is connected the lid 1 Press the lid open switch Opening Closing the lid 1 Put the lid on and press the edge of the lid If thelid is...

Page 10: ...ockwise and pull it completely out with the washer under the screw 2 Lift upthe rotor from the motor shaft 3 Load the rotor into the motor shaft 4 Align the washer with the hole at the top of the rotor 5 Insert the rotor lock screw into the screw hole in the center of the rotor and turnit clockwise using a flathead screwdriver to completely lock it 6 Check that the rotor is completely locked Flat ...

Page 11: ...ificInc Always use the same type of tube Tubes should be loaded symmetrically Do not exceed the maximum rated speed of the tube Same volume of sample should be put on tubes Check symmetric loading by balncing tubes with scales 1 Check the inside of the rotor hole for moisture or foreign matter 2 Tubes must be loaded symmetrically Correct arrangement ...

Page 12: ...ng knob Rotate clockwise or counterclockwise to set the run time To use pulse function set the time to 0 and press the start key Start key Stop key When using a A0 2 32 PCR strip rotor do not exceed 6 000rpm Rotate clockwise or counterclockwise to set the rpm value Start key Stop key ...

Page 13: ...time 0 15 min 1 Check the all parameters are correct and the lid is closed 2 Press the Start key Operation begins with a beep If the lid is not completely closed it will not operate When the set time is over the device is decelerated and stops with beep sound Press Stop key to abort centrifugation Set the Rpm setting knob or Time setting knob to 0 to abort centrifugation When the lid is opened dur...

Page 14: ...e device such as alchol benzene acetone or phenol 3 Use the stopwatch to check that the time setting is correct 4 Make sure do not scratch the surface of equipment when cleaning it Do not use a metal sponge If the device is rusted remove it with a mild detergent and wipe it with a dry cloth Chamber 1 If the rotor chamber is not dry wipe moisture from the chamber with a dry cloth 2 If the rotor cha...

Page 15: ...팀으로 문의하여 주십시오 Lid가 닫히지 않아요 Lid 걸쇠 부위가 파손되었는 지 확인하십시오 파손되었다면 라벡스 기술지원팀으로 문의해 주십시오 작동 중에 진동과 소음이 나타 나요 본체 설치 위치가 불안정하면 본체의 수평과 고정여부를 확인하고 평평한 곳에 수평을 맞춰 다시 설치하십시오 로터 장착상태가 불량한 경우 로터 탈착 후 로터 외관을 확인하고 파손된 부위가 있다면 로터 사용을 즉시 중지하십시오 또한 장착 방법이 잘못되었다면 3 5 로터 장착과 분리 를 참조하여 로터를 정확하게 장착하십시오 튜브 삽입이 비대칭이거나 무게가 맞지 않는 경우에는 3 6 튜브 장착 을 참조하여 튜브 무게를 확인하고 대칭적으로 삽입하십시오 6 Troubleshooting 6 1 Possible problems Please che...

Page 16: ...ice does not operate 2 The device stops during opertaion 3 There is no beep sound when power is connected Need torepair the controller Please contact your dealer 1 It operates when the lid is open 2 When press the start key only beeps 1 Rpm Time knob dose not rotate 2 Start stop key does not press 1 The lid does not close 2 The lid does not open Problem Recommended Action ...

Page 17: ...ml 0 5 ml 1 5 2 0 ml Adaptor None Cat No Adaptor bore Фx L mm 6 x 21 8 x 37 Radius mm 44 59 59 Max RPM 13 500 Max RCF 8 965 12 032 Tube Tube capacity ml 0 2 8 tube PCR strip Radius mm Inner line 31 13 44 06 Outer line 46 13 55 68 Max RPM 6 000 Max RCF g force Inner line 1 773 Outer line 2 241 4 x 8 tube PCR strips 32 x 0 2 ml 45o Hole diameter mm 6 5 PCR Rotor A0 2 32 TR0 2 TR0 5 12 032 ...

Page 18: ...Hanil ScientificInc 16 Arayukro Gimpo10136 Rep of KOREA T 82 2 3452 8965 info ihanil com www ihanil com ...