Flange Fine Adjustment Alignment Kit
H&S offers this fine adjustment
flange facing alignment kit to
provide the most accurate setup
possible.
Insert the center shaft/locking
mechanism into the pipe.
Tighten the draw rod just
enough to stabilize the position.
The alignment fixture slides onto
the shaft until the four adjusting
screws contact the flange
surface. The fixture is locked in
place with the locking set screw.
There is a choice of dial
indicator mounts. The magnetic
base mounts by setting the unit
on the bracket and turning the
switch to "on". The arms are
adjusted to a position where
the dial indicator can be swung
a full 360 degrees without
interference.
The kit also includes threaded
extension rods and clamps for
mounting the dial indicator.
Tapped holes are provided on
the flat and side of the mounting
bracket into which a rod can be
located. The C-clamp can be
locked on that rod and another
rod affixed to the clamp to hold
the indicator. There are various
combinations to give you a
setup that will clear surrounding
obstructions.
Tool Post Holder
Swivel
Clamp
C-Clamp
Magnetic Base
Fine Adjustment
Alignment Fixture
Extension
Rods
Needle
Extension
Dial
Indicator
Off
Adjusting Screw
Arms
Locking
Screw
Mounting
Bracket
Once the dial indicator is secured
in position with the indicator
sensor in contact with the flange
face, the fixture is rotated to
swing the indicator around the
surface. The adjusting screws are
then used to square the
centershaft with the flange. The
mandrel is then locked in place,
the fixture/dial indicator is
removed and the flange facer is