Flange Fine Adjustment Alignment Kit

H&S offers this fine adjustment 

flange facing alignment kit to 

provide the most accurate setup 

possible.

Insert the center shaft/locking 

mechanism into the pipe. 

Tighten the draw rod just 

enough to stabilize the position. 

The alignment fixture slides onto 

the shaft until the four adjusting 

screws contact the flange 

surface. The fixture is locked in 

place with the locking set screw.

There is a choice of dial 

indicator mounts. The magnetic 

base mounts by setting the unit 

on the bracket and turning the 

switch to "on". The arms are 

adjusted to a position where 

the dial indicator can be swung 

a full 360 degrees without 

interference.

The kit also includes threaded 

extension rods and clamps for 

mounting the dial indicator. 

Tapped holes are provided on 

the flat and side of the mounting 

bracket into which a rod can be 

located. The C-clamp can be 

locked on that rod and another 

rod affixed to the clamp to hold 

the indicator. There are various 

combinations to give you a 

setup that will clear surrounding 

obstructions.

Tool Post Holder

Swivel 

Clamp

C-Clamp

Magnetic Base

Fine Adjustment

Alignment Fixture

Extension 

Rods

Needle

Extension

Dial 

Indicator

Off

Adjusting Screw

Arms

Locking 

Screw

Mounting

Bracket

Once the dial indicator is secured 

in position with the indicator 

sensor in contact with the flange 

face, the fixture is rotated to 

swing the indicator around the 

surface. The adjusting screws are 

then used to square the 

centershaft with the flange. The 

mandrel is then locked in place, 

the fixture/dial indicator is 

removed and the flange facer is 

Reviews: