GB
54
Installation distance to walls and ceiling
295
A 825
550
2000
Brännbart tak
455
165
D 55
B
705
C 100
Position the stove on a hearth plate and
check that the installation distances given
in the diagrams are met. The minimum
distance between the stove opening and
combustible parts of the building or décor
must be at least 1 m.
When top connecting a steel flue please
refer to the relevant manufacturer’s
installation instructions. Observe the safety
distances to combustible material that steel
flues require.
350
Brännbar vägg
150
785
695
315
Brännbar vägg
150
470
745
200
300
400
500
Tillåtet område för brännbart material
100
200
300
400
100
H53, H54 and H54T
* To prevent the discolouring of painted fire walls, we recommend a side distance the same as for the combustible wall.
** Minimum installation distance when using Handöl 50 base plate, applies when combustion air is obtained from the room
and when connecting outdoor air through the floor. If outdoor air is NOT to be connected through the floor, the stove can
be placed 50 mm from fire walls if Nibe’s tear-drop shaped base plate is used.
215
Brandmur
50
110*
385*
245, 350**
Brandmur
50, 150**
635, 785**
590, 695**
A = height from floor to top flue connection, Ø150
B = height from floor to c/c smoke outlet rear, Ø150
C = distance from back to top flue (c/c), Ø64 v
D = distance from back to smoke outlet rear, Ø150
280
Brännbar vägg
150
500
745
Tillåtet område för brännbart material
100
200
300
400
80
180
280
380
Combustible ceiling
Permitted area for combustible material.
Combustible wall
Fire-retardant wall of brick or concrete
Combustible wall
Fire-retardant wall of brick or concrete