background image

9 - 10

External Power Connector

DC power to the cordless Base can come from an external power supply or from
the terminal to which the Base is connected. External power is provided through
a two-position barrel-type connector on the Base’s back panel. The input voltage
range is 4 VDC to 14 VDC and the schematic diagram is shown below.

Ground

+9 Volts DC (example)

Summary of Contents for IMAGETEAM 3870

Page 1: ... SCANTEAM 2070 Base IMAGETEAM 3870 75 Linear Imager SCANTEAM 5770 Laser System Manual Cordless Scanning System ...

Page 2: ...tment on the part of HHP HHP shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into ...

Page 3: ... and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or television technician for help Caution A...

Page 4: ...II product requirements specified in the R TTE Directive The equipment is intended for use throughout the European Community but its authorization for use in France is restricted as follows PAN European Frequency Range 2 402 2 480 GHz Restricted Frequency Range for use in France 2 448 2 480 GHz Regulatory and Safety Agency Approvals Parameter Specification Electromagnetic Emissions Immunity U S A ...

Page 5: ...ith the Low Voltage Directive C S A Statement This product must be used with a certified Class 2 Power supply or be powered by a certified SELV Safety Extra Low Voltage output Patents The SCANTEAM 2070 SCANTEAM 5770 IMAGETEAM 3870 and IMAGETEAM 3875 are covered by one or more of the following U S patents 3 991 299 4 470 057 5 021 642 5 038 024 5 081 343 5 095 197 5 144 119 5 144 121 5 182 441 5 18...

Page 6: ...Welch Allyn Skaneateles Falls New York 13153 0187 USA See User Guide for Patent Information Made in USA Complies with en conformite avec FCC PART 15 CANADA ICES 003 See manual Reféréz vous à la documentation CISPR 22 CLASS B Contains TX FCC ID EHAUL ISC RSS CNR 210 CANADA 31101021090A MAY 2000 IMAGETEAM 3870 3870XX XX 12345 SW 1 6 1 08 ...

Page 7: ...elch Allyn Skaneateles Falls New York 13153 0187 USA See User Guide for Patent Information Made in USA Complies with en conformite avec FCC PART 15 CANADA ICES 003 See manual Reféréz vous à la documentation CISPR 22 CLASS B Contains TX FCC ID EHAUL ISC RSS CNR 210 CANADA 31101021090A AUGUST 2001 IMAGETEAM 3875 3875XX XX 12345 SW 1 6 1 08 ...

Page 8: ...h Allyn Skaneateles Falls New York 13153 0187 USA See User Guide for Patent Information Made in USA MAY 2000 IMAGETEAM 3870 3870XX XX 12345 SW 1 6 1 08 Complies with en conformite avec FCC PART 15 CANADA ICES 003 See manual Reféréz vous à la documentation CISPR 22 CLASS B Contains TX FCC ID EHAUL ISC RSS CNR 210 CANADA 31101021090A ...

Page 9: ...nditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that can cause un desired operation Canada ICES 003 See Manual Reféréz vous à la documentation CISPR 22 CLASS B Contains TX FCC ID EHAUL ISC RSS CNR 210 CANADA 31101021090A MANUFACTURED August 2001 MODEL SCANTEAM 2070 S N U 35 00134 ITEM 2070 1A REV 3 80 1 08 ...

Page 10: ......

Page 11: ...5770 Scanner Beep Indication 1 13 LED Sequences and Meaning ST2070 1 14 Basic Operation of the Cordless System 1 14 System Conditions 1 16 Communication Between the Cordless System and the Host 1 18 Auxiliary Port 1 20 Accessories for the Cordless System 1 22 Chapter 2 Quick Start Interface Menu Introduction 2 1 Plug and Play Selections 2 2 Industrial Interface IBM PC 2 2 Industrial Interface Aux ...

Page 12: ...3875 only 2 16 Factory Default and Revision Report Selections 2 17 Reset Factory Settings 2 17 Revision Report 2 17 Chapter 3 Communications Menu Introduction 3 1 Default Host Port Protocol 3 2 Baud Rate Selection 3 2 Parity Selection 3 3 Word Length Data Bits Selection 3 3 Word Length Stop Bits Selection 3 4 Hardware Flow Control Selection 3 4 Serial Wedge Output Selection 3 5 Host ACK Enable 3 7...

Page 13: ...itor Commands 3 25 Aux Data Format Editor 3 27 Aux Data Formatter 3 28 Alternate Aux Data Formats 3 28 Chapter 4 IMAGETEAM 3875 Features Introduction 4 1 IT3875 Keypad 4 1 Key Shifting Alpha Characters 4 1 Enter Backspace 4 2 Keypad Macros 4 2 Arrow Keys 4 2 Scrolling 4 2 Display 4 3 Function Key 4 3 System Setup 4 5 Script Menu 4 5 IT3875XXX X2 0 Script Setup 4 6 IT3875XXX X2 1 Script Setup 4 6 R...

Page 14: ... 5 10 Beeper Volume Selection 5 11 Beeper Pitch 5 11 Scanner Voting Selection 5 12 Laser Marker Beam ST5770 only 5 13 AIM Symbology ID and Modifier Prefix 5 13 HHP Code ID Prefix 5 14 Symbology Chart 5 15 Prefix Suffix Selections 5 16 Prefix Selections 5 18 Suffix Selections 5 18 Exit Selection for Prefix Suffix 5 19 Work Group Prefix On Off 5 20 Suffix On Off 5 20 Decimal to Hex to ASCII Conversi...

Page 15: ... 6 12 Interleaved 2 of 5 6 13 Interleaved 2 of 5 Message Length 6 14 Check Digit 6 15 Code 2 of 5 6 16 Code 2 of 5 Message Length 6 17 Matrix 2 of 5 6 18 Matrix 2 of 5 Message Length 6 19 Code 11 6 20 Code 11 Check Digits Required 6 20 Code 11 Message Length 6 21 Code 128 6 22 Code 128 Message Length 6 23 GS Substitution 6 24 ISBT 128 6 24 Telepen 6 25 Telepen Message Length 6 26 Telepen Output 6 ...

Page 16: ... Composite 6 38 Enable UPC EAN Version 6 38 EAN UCC Composite Symbology Message Length 6 39 EAN JAN 8 6 40 EAN JAN8 Check Digit 6 40 EAN JAN 13 6 41 EAN JAN 13 6 41 EAN JAN13 Check Digit 6 41 ISBN 6 41 UPC A 6 42 UPC A Check Digit 6 43 Number System 6 43 UPC E0 6 44 UPC E0 Check Digit 6 44 Number System 6 44 Version E Expand 6 45 UPC E1 6 45 EAN UPC Addenda 6 46 EAN Addenda 6 46 UPC Addenda 6 47 C...

Page 17: ...Cordless Linear Imager Scanner Product Specifications 9 3 IMAGETEAM 3875 Cordless Linear Imager Scanner Product Specifications 9 4 SCANTEAM 5770 Cordless Laser Scanner Product Specifications 9 5 Charge Pack Specifications CLESS NIMH S 9 6 Connectors Pinouts 9 7 Auxiliary RS 232 Wand Emulation Connector 9 8 Keyboard Terminal and RS 232 Host Port Connector 9 9 External Power Connector 9 10 Cordless ...

Page 18: ...rdless Scanner and Cordless Base Housings 10 1 Care and Handling of the Charge Pack 10 2 Replacing the Interface Cable 10 2 Recharging and Replacing the Cordless Scanner s Charge Pack 10 2 To Reset Factory Settings 10 2 Troubleshooting 10 3 Chapter 11 Customer Support Obtaining Factory Service 11 1 Help Desk 11 3 Limited Warranty 11 4 ...

Page 19: ...12 4 Interleaved 2 of 5 Selection 12 4 Code 2 of 5 Selection 12 4 Matrix 2 of 5 Selection 12 4 Code 11 Selection 12 5 Code 128 Selection 12 5 Telepen Selection 12 5 China Post Code Selection IT3870 IT3875 only 12 5 RSS 14 Selection IT3870 IT3875 only 12 5 PDF417 Selection IT3870PDF IT3875PDF only 12 5 MicroPDF417 Selection IT3870PDF IT3875PDF only 12 6 EAN UCC Composite Symbology Selection IT3870P...

Page 20: ...x ...

Page 21: ...oader is used to compile and load custom script applications created with a text editor IQ App Designer an optional PC software tool automates the creation of scripts and the task of loading a user script application to the system Using IQ App Designer you may build custom script applications with minimal programming experience The cordless system is an economical durable solution for a wide varie...

Page 22: ...accomplished by using the single programming bar codes in this manual This section contains the following information Cordless System Main Components Charge Pack and Charging Information Cordless System Set Up and Connection Beeper and LED Sequences and Meaning Basic Operation of the Cordless System Communication Between the Cordless System and the Host Accessories for the Cordless System ...

Page 23: ...w Trigger Charge Pack Charge Pack Clip 2 places Cordless Scanner Left Side View with charge pack Antenna Keyboard Terminal and RS 232 Connector Host Port External Power Connector Aux RS 232 Service Port and Wand Emulation Output Connector Cordless Base Back View ...

Page 24: ...pplications it may be charged worldwide Inexpensive snap on adapters and custom 2 bay and 6 bay charge strips are available to accommodate a wide variety of electrical outlets internationally Charge Pack Recommendations Charge packs are shipped uncharged and need to be conditioned for full capacity and longer life To maintain the maximum charge capacity charge packs should be allowed to fully disc...

Page 25: ...f the charge initialization sequence After initialization the LED remains solid red while the charge pack is charging The LED shows green when the charge pack is fully charged and ready to use Recharge Time 6 hours at any voltage at 20 C 68 F 4 After the charge pack is fully charged attach it to the cordless scanner by pressing the pack firmly align the prongs on the pack with the mating recep tac...

Page 26: ...ging the Charge Pack A full discharge should take less than 10 hours Full discharge is indicated when the trigger is pulled and held for at least 10 seconds and the reader does not illuminate the aiming line or the status LED Circuitry in the reader prevents an over discharge IMAGETEAM 3870 SCANTEAM 5770 The charge packs naturally discharge through normal use of the reader Alternately they may be ...

Page 27: ... You may automatically discharge the IT3875 charge pack by scanning the following bar code The scanner remains operational during the discharge however the status LED flashes like a heartbeat IT3875 Charge Pack Discharge ...

Page 28: ...ication the interface cable you need may be different than the one shown Note For optimal coverage place the base and its antenna as far away from other sources of RF interference with a clear transmitting path to the scanner s The base can be mounted on a wall or a ceiling Try to place the base so that the antenna is in a vertical straight up and down position whenever possible An extra Base Asso...

Page 29: ... use an external power supply Contact your distributor for more information on ordering power supplies or RS 232 cables 3 Turn on the power to the host system Verify that the base is on the green LED on top of the unit should be on The base does not have a beeper Terminal Host system Cordless Base 3 1 Cable keyboard and terminal may vary 2 Power Supply RS 232 Interface Example ...

Page 30: ...ge pack is installed then beeps a second time after full association typically five to ten seconds later Note A scanner always defaults to work group 0 after scanning a base I D bar code 5 After your cordless scanner has been associated with its base unit program the system to work with your terminal or computer by scanning the Terminal Setup Codes Use the Supported Terminal list page 2 6 to scan ...

Page 31: ...e stores a unique I D for each scanner up to nine to identify the scanner during data communication Two beeps followed by clicking then a single beep from the scanner indicates a good association The base rejects a tenth cordless scanner trying to link to its network sending the scanner an error command A rejected scanner beeps three times indicating an unsuccessful association Note When you assoc...

Page 32: ...ing PDF417 decoding The table below lists the indication and cause of the LED illumination and beeps for the IT3870 IT3875 LED Indication Beeper Indication Cause Normal Operation Steady Yellow IT3870 None Working busy Yellow blinking None Battery low Steady yellow Clicking Indicates an association attempt Steady yellow Ticking humming Indicates PDF417 or MicroPDF417 decoding in process Steady gree...

Page 33: ...g mode Green LED blinks 2 seconds Unsuccessful parameter change in programming mode Yellow LED on Scanning trigger pulled in or out of range Yellow LED blinks Low battery trigger pulled Sequence Meaning No beep No scanning scanning or low battery trigger pulled 1 beep Successful decode and communication Clicking then1 beep Successful reassociation Clicking only Unsuccessful reassociation 2 beeps c...

Page 34: ...en the cordless scanner and the control interface assembly The control assembly coordinates the central interface activities including transmitting receiving commands and data to from the host system performing software activities parameter menuing visual indicator support power on diagnostics and data translation required for the host system Sequence Meaning LED on continuously Power on system id...

Page 35: ... models for compliance in most countries In North America the radio is approved under the standards in FCC B Part 15 249 regulations and in Europe under the standards in ETS 300 328 regulations Cordless Scanner The cordless scanner enables fast and accurate bar code scanning using a non contact linear imager or laser input engine The scanner maintains radio communication with the base unit up to 1...

Page 36: ...g and data transmission is interrupted If the base is off or not working properly the scanner emits an error triple beep after trying for 30 seconds to associate to the base The work group table is also uploaded any time the base believes a previously associated scanner wishes to join the network A scanner always tries to join the last base it was associated to even if the scanner has been without...

Page 37: ...single beep when the reassociation process uploading of the parameter table is complete If you believe you are in range and are still hearing a triple error beep you may have been removed from the base s network This could happen if the scanner loses power or goes out of range for three seconds Try scanning the association label or reset the scanner by removing and reinserting the charge pack Repl...

Page 38: ...either case the scanners automatically reassociate if they are within range Reassociation The process of uploading the work group parameter table from the base is called reassociation During reassociation the scanner clicks then beeps once Reassociation is done automatically without having to scan an association label Association List The base keeps an association list of up to nine entries This l...

Page 39: ...en properly sent to the host system the scanner issues an error indication You must then check to see if the scanned data was received by the host system Acknowledgement from the Base If the cordless system is configured for a keyboard wedge host interface a signal ACK is sent from the base confirming that the data was received and is being sent on to the host system Since keyboard wedge interface...

Page 40: ... to be an RS 232 output port For all other interfaces the Aux Port is available as an RS 232 input port Peripheral devices can send data into the Aux Port and the data is automatically sent out the main port to the host system Note The Auxiliary Port cannot be used as an input when the base is configured for the following interfaces Non Decoded Laser Emulation HHLC wand emulation and terminal ID 0...

Page 41: ...ecommended that the incoming message be framed by known start and stop characters These characters are attached to the message by the input peripheral and the base is then programmed to look for these characters The base unit is then able to recognize the beginning and end of a message eliminating the possibility of partial messages being sent to the host system Use the Data Character Selection ba...

Page 42: ...faces The charge strip uses a standard PC IEC 320 grounded power cord between the charge strip and the electrical AC outlet Note International versions of the power cords are provided by HHP s country partners or may be purchased from your local PC supplier HHP does not supply these power cords Charge Pack Adapters Charge pack adapters allow the charge pack to be plugged directly into many interna...

Page 43: ...ows you to download firmware upgrades change programmed parameters and create and print programming bar codes Please refer to Chapter 7 for information about installing Visual Menu from the HHP web site IQ App Loader IT3875XXX X2 1 and ST2070 5 only IQ App Loader is a PC tool that takes script applications you create in a text editor and compiles and loads them into the ST2070 5 base Please refer ...

Page 44: ...1 24 ...

Page 45: ...em certain operating parameters have already been set These are the factory defaults indicated by an asterisk on the programming pages beneath the default programming bar code Default Charts that list all the factory settings may be found near the end of this System Manual A Programming Chart found on the inside back cover of this manual contains alphanumeric bar codes for setting additional progr...

Page 46: ...ar code above also programs a CR carriage return suffix Industrial Interface Aux Port RS 232 Note The bar code above also programs the following parameters Programmable Option Setting Baud Rate 38 400 bps Parity None Data Format 8 data bits 1 stop bit Prefix None Suffix CR IBM PC AT and Compatibles Interface also PS 2 30 286 50 55SX 60 70 70 061 70 121 80 RS 232 Interface ...

Page 47: ...gram the interface for IBM 4683 Port 5B 9B or 17 Note When using any of the IBM 4683 interfaces the maximum allowable data rate into the base aux port is 9600 baud IBM 468X 9X Port 5B Interface IBM 468X 9X Port 9B HHBCR 1 Interface IBM 468X 9X Port 9B HHBCR 2 Interface IBM 468X 9X Port 17 Interface ...

Page 48: ...on Setting Transmission Rate 25 inches per second Output Polarity White High Note When in Wand Emulation mode bar code data containing more than 48 characters may not be sent to the host device Wand Emulation Code 39 Format Interface Wand Emulation Same Code Format Interface Supports Code 39 UPC EAN Code 128 Interleaved 2 of 5 and Codabar All other codes are output as Code 39 Wand Emulation Code 3...

Page 49: ... Laser Emulation HHLC Use HHLC when connecting to a secondary terminal with integral decoding This setting also sets the transmission rate to 37 scans per second and polarity to white high Non Decoded Laser Emulation ...

Page 50: ...ull BDS 7 Honeywell HDS 7 035 Citadel TS90XX Keyboard Wedge 003 Citadel Direct Connect 003 DEC PC433 SE Portable PC 003 DEC VT 220 320 330 340 420 004 DEC VT 510 520 525 PC Style 005 DEC VT 510 520 525 DEC Style LK411 104 DELL Latitude Portable PC 003 DTK 486 SLC Portable PC 003 Falco 5220 047 Fujitsu Point 510 003 Fujitsu Point 1600 003 Fujitsu Stylistic Portable PC 003 Honeywell HDS7 035 HHLC No...

Page 51: ...022 Portable PC 003 Olivetti M19 M24 M28 M200 001 Olivetti M240 M250 M290 M380 P500 003 Relisys TR 175 003 RS 232 Host Port 050 RS 232 Aux Port 000 Serial Wedge 050 Televideo 990 995 9060 002 Texas Instruments Extensa 560CD Portable PC 003 Toshiba 2600 Portable PC 003 Toshiba Satellite T1960 T2130 CS Portable PC 003 Wand Emulation Code 39 output via Aux Port Wand Emulation Same Code output via Aux...

Page 52: ...the keyboard layout for your selected country As a general rule the following characters are not supported by the cordless system for countries other than the United States United States Belgium Denmark Finland Norway Sweden France Germany Austria United Kingdom Switzerland Italy ...

Page 53: ...u normally have the Shift Lock key on not common to U S keyboards Automatic Caps Lock is used if you change the Caps Lock key on and off The software tracks and reflects if you have Caps Lock on or off AT and PS 2 only This selection can only be used with systems that have an LED that notes the Caps Lock status Emulate External Keyboard should be scanned if you do not have an external keyboard IBM...

Page 54: ...ol characters for values 00 1F Refer to page 8 1 for CTRL Values Turbo Mode Selecting Turbo Mode On for the IBM AT only programs the cordless system to send characters to the terminal faster Numeric Keypad Mode Selecting Numeric Keypad Mode On sends numeric characters as if entered from a numeric keypad Control ASCII Mode On Control ASCII Mode Off Turbo Mode On Turbo Mode Off Numeric Keypad Mode O...

Page 55: ...y between data characters output by the cordless system to the host terminal Interfunction Delay is the time delay between function key codes output by the cordless system to the host terminal Intermessage Delay is the time delay between data messages or records output by the cordless system to the host terminal Example You need a 45 millisecond delay Scan the Intercharacter Delay bar code Scan 0 ...

Page 56: ...ate Selection This programming selection sets the transmission rate from 10 ips inches per second to 300 ips if the cordless system is in Wand Emulation mode Programming the transmission rate causes the data to be sent at the specified rate The programmed transmission rate must be compatible with the device receiving the bar code data 10 25 40 80 120 150 200 300 ...

Page 57: ...2 13 Output Polarity Selection This selection allows you to set the output logic convention for the digital output The choices are White High and Black High White High Black High ...

Page 58: ... may want the base unit to draw less power when it is being powered by a portable data terminal or laptop Use Base Low Power mode to tell the base to draw less power Note Using Base Low Power Mode increases latency in radio communications On Off ...

Page 59: ...ext trigger pull the scanner begins the reassociation process to restore the radio link and the workgroup configuration settings This setting is recommended if the scanner is left inactive for long periods of time during the workday or if the charge pack is left attached when the scanner is not in use The Check base network before timeout mode is identical to the previous mode except that when the...

Page 60: ...When the scanner goes to sleep the keypad is temporarily disabled To wake the scanner from the sleep mode pull the trigger or press ENTER Pressing the ENTER key wakes the system even if the executing script is not accepting keypad input Timeout after 15 minutes Timeout after 30 minutes Timeout after 45 minutes Timeout after 1 hour ...

Page 61: ...pter 12 for a listing of all the factory defaults Revision Report Scan the Report Base Software Revision bar code to transmit the cordless base software revision level to the host terminal The base software revision will be printed out as Base software revision X XX Radio K KK The Xs and Ks will vary according to the firmware revision Scan the Report Scanner Software Revision bar code to transmit ...

Page 62: ...2 18 ...

Page 63: ...ion Use this section to program the communications parameters for the cordless system This programming section contains the following menu selections Host Port Protocol Communications RS 232 Auxiliary Port Protocol Communications RS 232 ...

Page 64: ... This selection sets the baud rate from 300 bits per second to 38 400 bits per second Programming baud rate causes the data to be sent at the specified rate The host terminal must be set up for the same baud rate as the cordless system to ensure reliable communication 300 600 2400 1200 4800 9600 38400 19200 ...

Page 65: ... up for the same parity as the cordless system to ensure reliable communication Word Length Data Bits Selection This selection sets the Word Length at seven or eight bits of data per character If an application requires only ASCII Hex characters 0 through 7F decimal text digits and punctuation select 7 data bits For applications requiring use of the full ASCII set select 8 data bits per character ...

Page 66: ... stop bits Hardware Flow Control Selection This selection turns on hardware flow control that checks for a CTS signal before sending data This option is useful when your application supports the CTS signal Note This selection cannot be used with Serial Wedge Output Selection 1 Stop Bit 2 Stop Bits On Off ...

Page 67: ...l output direction required by your application P1 and P2 are serial wedge designations printed on the serial wedge cable Usually one goes to the host and one goes to the terminal depending on your specific application and the serial wedge cable To P1 To P1 and P2 To P2 None Host Port RS 232 ...

Page 68: ...cape commands are addressed to the source scanner via Application Work Groups Once a command is sent all scanners in a group respond to that command Because of this situation it is recommended that each scanner is assigned to its own group The commands to which the scanner responds are listed on page 3 8 and page 3 9 The ESC is a 1B hex A typical command string is y ESC x where y is the applicatio...

Page 69: ...d beeps at the same pitch A time out occurs if the source scanner does not receive a valid escape command in 10 seconds If a time out occurs the operator should check the host system to understand why a response to the scanner was not received Host ACK Enable On Off ...

Page 70: ...te green LED for two seconds ESC b Beep three low tones illuminate green LED nine times ESC 1 Illuminate green LED for 135 milliseconds ESC 2 Illuminate green LED for two seconds ESC 3 Illuminate green LED for five seconds ESC 4 One beep at low volume ESC 5 One beep at medium volume ESC 6 One beep at high volume ESC 7 Beep one medium tone illuminate green LED two seconds ESC 8 Beep three low tones...

Page 71: ...rk time when multiple blinks ESC 2 Illuminate green LED for two seconds followed by at least 500 mSecs dark time when multiple blinks ESC 3 Illuminate green LED for five seconds followed by at least 500 mSecs dark time when multiple blinks ESC 4 One beep at low volume ESC 5 One beep at medium volume ESC 6 One beep at high volume ESC 7 Indicate as successful decode and communication to host ESC 8 I...

Page 72: ... the host Should you also want the scanner to beep when a bar code has been successfully decoded and successfully communicated to the base turn the Decode Beep Selection on When Data Format Required is on the scanner will only beep if the input data conforms to the edited format or triple beep if it does not meet the format requirements Should you also want the scanner to beep when a bar code has ...

Page 73: ...s selection sets the baud rate from 300 bits per second to 38 400 bits per second Programming baud rate causes the data to be sent at the specified rate The device connected to the Auxiliary Port must be set up for the same baud rate as the Aux Port to ensure reliable communication 300 600 2400 1200 4800 9600 38400 19200 ...

Page 74: ...ry Port must be set up for the same parity as the Aux Port to ensure reliable communication Word Length Data Bits Selection This selection sets the Word Length at seven or eight bits of data per character If an application requires only ASCII Hex characters 0 through 7F decimal text digits and punctuation select 7 data bits For applications requiring use of the full ASCII set select 8 data bits pe...

Page 75: ...rdware flow control that checks for a CTS signal before sending data This option is useful when your application supports the CTS signal Note The Auxiliary Port receive function will only work properly if RTS CTS or ACK NAK flow control is used If your host system does not support RTS CTS or ACK NAK handshaking some or all of your data will be lost 1 Stop Bits 2 Stop Bits On Off ...

Page 76: ...he Terminal ID as 51 see page 2 6 Then scan one of the programming codes below for your 4683 Async Address selection Note When using any of the IBM 4683 interfaces the maximum allowable data rate into the base aux port is 9600 baud Address 68 Socket 23 2A Left Address 69 Socket 23 2B Right Address 65 Socket 25 2B Right Aux Port Disable Address 64 Socket 25 2A Left ...

Page 77: ... to work correctly The cordless system must be configured for Aux Port RS 232 Terminal ID 000 Both the host terminal and the cordless system must have RTS CTS handshaking Hardware Flow Control Selection on page 3 4 enabled Host Commands are addressed to an individual scanner using a four character Scanner ID The scanner must be expecting the Host Command This is accomplished using one of three Ver...

Page 78: ...ata that are to be appended together within the base and sent to the host system as a single message The programmer should determine which of the four selections below best meets the requirements of the peripheral Record used when the transmitting peripheral is sending messages when no confirmation of receipt is required Record ACK NAK same as Record however the base responds to the peripheral upo...

Page 79: ...ithin the base and are not sent to the host system The bar codes below are used to configure the base to conform to the specific framing characters sent from the peripheral device SOR used to program the starting frame character of a record EOR used to program the ending frame character of a record SOB used to program the starting frame character of a block EOB used to program the ending frame cha...

Page 80: ...n the two digits on the Programming Chart on the inside back cover of this manual Step 3 Refer to the Hex ASCII Chart page 3 20 to find the Hex value that represents the ASCII characters you wish to attach to the data Use the Programming Chart inside back cover to scan the alphanumeric combination that represents the ASCII characters Step 4 To complete Aux Prefix Suffix programming scan either Sav...

Page 81: ...ex ASCII Chart Scan 0 and 9 on the Programming Chart Step 4 Scan Save Example 2 Add a Suffix To add a CR carriage return Suffix to incoming data Step 1 Scan the Add Aux Suffix Suffix Selection bar code Step 2 Scan 7 and 2 on the Programming Chart inside back cover Step 3 A CR is equivalent to 0D see the Hex ASCII Chart Scan 0 and D on the Programming Chart Step 4 Scan Save Note If the Aux Port ID ...

Page 82: ... 0B VT 43 2B 75 4B K 107 6B k 12 0C FF 44 2C 76 4C L 108 6C l 13 0D CR 45 2D 77 4D M 109 6D m 14 0E SO 46 2E 78 4E N 110 6E n 15 0F SI 47 2F 79 4F O 111 6F o 16 10 DLE 48 30 0 80 50 P 112 70 p 17 11 DC1 49 31 1 81 51 Q 113 71 q 18 12 DC2 50 32 2 82 52 R 114 72 r 19 13 DC3 51 33 3 83 53 S 115 73 s 20 14 DC4 52 34 4 84 54 T 116 74 t 21 15 NAK 53 35 5 85 55 U 117 75 u 22 16 SYN 54 36 6 86 56 V 118 76...

Page 83: ...en one or more two digit numbers and Save after scanning this pro gramming bar code Refer to the Programming Chart inside back cover Exit Selection for Aux Prefix Suffix Add Aux Prefix1 Default Aux Prefix none Clear All Aux Prefixes Add Aux Suffix1 Default Aux Suffix CR Clear All Aux Suffixes Save Discard ...

Page 84: ...tting These codes are used when you want to toggle between turning on and off the prefix and or suffix formatting Aux Suffix On Off Aux Port I D Transmit Selection This will attach the Aux Port identifier which is the letter r to the incoming data at the Auxiliary Port and will send it along with the data to the host device On Off On Off On Off ...

Page 85: ...te formats Alternate formats allow you single shot capability to scan one bar code using a different aux data format After the one bar code has been read the scanner reverts to the primary aux data format See page 3 28 If you are programming the primary format scan 0 If you are programming an alternate format scan 1 2 or 3 depending on the alternate format you are programming Step 3 Terminal Type ...

Page 86: ...at you want to delete That length aux data format for that symbology is deleted and all other formats are unaffected Save This exits saving any Aux Data Format changes Discard This exits without saving any Aux Data Format changes Aux Data Formatter Example Five digit data is sent to the Auxiliary Port however the host system can only accept eight digit data Three zeroes must be added to the beginn...

Page 87: ... ASCII codes see Hex to ASCII Conversion chart page 3 20 F4 Send xx character nn times Insert leaving cursor in current cursor posi tion Syntax F4xxnn xx stands for the hex value for an ASCII code see Hex to ASCII Conversion chart page 3 20 and nn is the numeric value 00 99 for the number of times it should be sent E9 Send all but the last nn characters starting from the current cursor posi tion S...

Page 88: ...st of characters to be suppressed xx stands for the hex value for an ASCII code see Hex to ASCII Conversion chart page 3 20 FC Disable suppress filter and clear all suppressed characters Syntax FC E4 Replaces up to 15 characters in the data string with user specified charac ters Replacement continues until the E5 command is encountered Syntax E4nnxx1xx2yy1yy2 zz1zz2 where nn is the total count of ...

Page 89: ...ormat Editor See through page 3 23 through page 3 26 for a description of Aux Data Format selections and commands Enter Aux Format Clear One Aux Data Format Save Current Changes Default Aux Data Format Clear All Aux Data Formats Discard Current Changes ...

Page 90: ...ity to edit incoming data using a different aux data format than your primary aux format When aux data formats are programmed see page 3 18 you must input whether you are programming the primary aux format or an alternate format numbered 1 2 or 3 An alternate aux format is initiated by scanning one of the 3 alternate aux format bar codes below The base will edit the incoming data formatting the da...

Page 91: ...ve coating on keys Exceptional tactile response to keystrokes If you are unable to scan a bar code that is damaged you may use the keypad to type in the bar code data giving you multiple methods for entering your data Key Shifting Alpha Characters The trigger is used to cycle through the available characters that are printed on a key as long as the key is depressed When a key is pressed the curren...

Page 92: ...be recalled by pressing FUNCTION FN and a digit key 0 9 or the asterisk the wildcard key Keypad macro strings can be used in combination with individual keyed characters See Application Work Group Selection on page 5 3 for macro programming instructions Note The scanner must be associated to a base ST2070 5 to use a macro Arrow Keys Up and down arrow keys are located below the display These keys a...

Page 93: ...ing contrast and backlight control The Function key is used in combination with the BK and ENTER keys to activate the System Setup Refer to System Setup on page 4 5 It is also used in conjunction with a digit to display a programmed keypad macro Contrast Control The contrast control makes adjustments to accommodate a range of viewing angles The middle setting is optimized for the nominal viewing a...

Page 94: ... the backlight In the ON state the backlight is on regardless of the script application Battery Radio Indicators To view battery and radio status press and release the FN key and then the wildcard key System icons and 4 segment bar graphs indicate battery strength and radio contact with the base The battery and radio status view closes when you pull the trigger press any key or when a timeout expi...

Page 95: ...t size and prompts using the English language The display shows the title and only three menu items at a time Additional options may be viewed pressing the UP or DOWN arrow keys The System Setup Main menu is illustrated below Script Menu The IT3875 ships with 2 factory scripts and a product demo installed A different custom script may be loaded for each work group The choice of a factory or custom...

Page 96: ...Note If custom script is selected and no custom script has been loaded the scanner is operational however nothing appears on the display and keypad input is not allowed Run History Factory Script This script keeps the history of the past ten scans on the display After you scan a bar code or enter keypad data and the information is successfully communicated to the base the bar code information appe...

Page 97: ...pt This script first prompts for PART You can either scan a bar code representing the part number or type in the part number on the keypad The part number may be composed of any character The part number will not be sent to the base until after the quantity is entered You then will be prompted to enter a quantity only digits are accepted After entering the quantity the scanner concatenates the par...

Page 98: ...code Product Demo Script This script runs a demo that describes the top selling features of the IT3875 You may press the ENTER key to step through the demonstration Instead of selecting the Product Demo script from the display you may scan the following bar code Run Part Number and Quantity Script Run Demo Script ...

Page 99: ...ner resident model VersaCode programs are stored in the base unit and run in the scanner In the host command model VersaCode commands are sent from the host to the scanner through the base In the remote procedure calls model VersaCode routines are resident in the scanner and activated using host commands For additional information please refer to the VersaCode Language Reference User s Guide Note ...

Page 100: ...Work Group The ST2070 5 supports four work groups or scanner personalities A work group is the collection of parameters that control the scanner s behavior An asterisk in the first position indicates the work group to which the scanner is currently assigned Once you select another work group the base is contacted and the settings for the new work group are uploaded to the scanner The Work Group di...

Page 101: ...ts a successful menu change beep and displays the new ID Press an additional key exits the System Setup To restore the factory scanner ID press or select option 1 then press ENTER System Info The System Info screen provides information about the software contained in the scanner An example is illustrated below If you need technical support for your IT3875 record the software product revision and p...

Page 102: ...4 12 ...

Page 103: ...can have nine associated scanners and nine work groups The ST2070 5 can have nine associated scanners and four work groups In each application work group the user settings are a configuration of programming selections found in this section of the manual The keypad macro settings for the IT3875 will be implemented as a programming selection as well For example one group may need the beeper turned o...

Page 104: ... These properties are not part of an application work group Note To program a group s parameters you must first scan the group number and then the programming selections prefix suffix data formatter etc The parameters can t be programmed first and then made a group by scanning an application work group number To remove a scanner associated with a base unit use the Remove Scanner Selection on page ...

Page 105: ...uires Refer to the introduction page 5 1 for more information about application work groups Notice that work groups 0 8 apply to the ST2070 1 and work groups 0 3 apply to the ST2070 5 If you scan work group 4 8 when using a ST2070 5 you will need to re associate with the base by scanning the base I D bar code again Note A scanner always defaults to work group 0 after scanning a base I D bar code S...

Page 106: ...5 4 ST2070 5 Remove Scanner Selection This programming selection removes a scanner from an associated base unit Group 0 Group 1 Group 2 Group 3 Remove Scanner ...

Page 107: ...d on the back cover scan the correct characters and Save again Example If you want to create a macro of the word PRODUCT and assign it to the key follow the sequence below You may assign up to 20 characters to each keypad macro Upon pressing a macro key each character of the keypad macro string will be shown in the display as if each character was keyed in by itself The keypad macro string will no...

Page 108: ...5 6 Initiate Key Macro IT3875 and ST2070 5 only FN 0 FN 1 FN 2 FN 3 FN 4 FN 5 FN 6 FN 7 FN 8 FN 9 Asterisk Macro ...

Page 109: ...09 HT 29 49 l 69 i 0A LF 2A 4A J 6A j 0B VT 2B 4B K 6B k 0C FF 2C 4C L 6C l 0D CR 2D 4D M 6D m 0E SO 2E 4E N 6E n 0F SI 2F 4F O 6F o 10 DLE 30 0 50 P 70 p 11 DC1 31 1 51 Q 71 q 12 DC2 32 2 52 R 72 r 13 DC3 33 3 53 S 73 s 14 DC4 34 4 54 T 74 t 15 NAK 35 5 55 U 75 u 16 SYN 36 6 56 V 76 v 17 ETB 37 7 57 W 77 w 18 CAN 38 8 58 X 78 x 19 EM 39 9 59 Y 79 y 1A SUB 3A 5A Z 7A z 1B ESC 3B 5B 7B 1C FS 3C 5C ...

Page 110: ... ê 8B AB CB Ë EB ë 8C Œ AC CC Ì EC ì 8D AD CD Í ED í 8E Ž AE CE Î EE î 8F AF CF Ï EF ï 90 B0 D0 Ð F0 ð 91 B1 D1 Ñ F1 ñ 92 B2 D2 Ò F2 ò 93 B3 D3 Ó F3 ó 94 B4 D4 Ô F4 ô 95 B5 µ D5 Õ F5 õ 96 B6 D6 Ö F6 ö 97 B7 D7 F7 98 B8 D8 Ø F8 ø 99 B9 D9 Ù F9 ù 9A š BA DA Ú FA ú 9B BB DB Û FB û 9C œ BC DC Ü FC ü 9D BD DD Ý FD ý 9E ž BE DE Þ FE þ 9F Ÿ BF DF ß FF ÿ Hex ASCII Hex ASCII Hex ASCII Hex ASCII ª ...

Page 111: ...codes below The small size font supports 4 lines of 16 characters each The medium size supports 12 characters on 3 lines and large size supports 8 characters on 2 lines Note After changing font size it is recommended that you disconnect and reconnect the charge pack to the scanner to update the display VeryClear Small VeryClear Medium VeryClear Large ...

Page 112: ...d the Part Number and Quantity prompts to appear in French scan the French bar code that follows The English prompts and the French equivalents are shown below Note After changing the language preference it is recommended that you disconnect and reconnect the charge pack to the scanner to update the display English French Part Article Qty Nombre Transmit Error Want to Retry Yes No Erreur Voulez vo...

Page 113: ...sh to set your beeper to a higher or lower pitch This feature is helpful if there are several scanners being used in close proximity Different pitches make it easier to distinguish which scanner is beeping Off Low Medium High Low Medium Medium High High ...

Page 114: ...ot be transmitted Refer to Data Formatter Selections page 5 22 to set format requirements Refer to Chapter 6 to set message length requirements by symbology Note To maximize both decoding speed and security it is recommended to disable all symbologies that will not be used When voting is turned off a bar code needs only to be read one time for a decode When the normal voting level is selected a ba...

Page 115: ...If this selection is turned on scanning is delayed for 0 5 or 1 2 seconds while the marker beam is enabled AIM Symbology ID and Modifier Prefix This selection turns the transmission of the AIM Symbology ID on or off before the decoded symbology See the Symbology Chart below for the single AIM character code that identifies each symbology When you scan the On code all current prefixes are cleared t...

Page 116: ...y See the Symbology Chart below for the single character code that identifies each symbology When you scan the On code all current prefixes are cleared then an HHP Code ID for all symbologies is programmed Alternately you may combine an HHP Code ID with other characters in a prefix or suffix Refer to page 5 16 On Off ...

Page 117: ... Code 39 Am b PDF417 Lm r UPC Em c MicroPDF417 Lm R EAN Em d Reduced Space Symbology RSS em y Interleaved 2 of 5 Im e EAN UCC Composite em y Code 2 of 5 IATA with 2 bar start stop patterns Rm f China Post Code Xm q Code 2 of 5 Indus trial with 3 bar start stop patterns Sm f Keypad Input Z0 k Code 11 Hm h Host Command Response Z7 7 Code 93 Gm i Host Input Z8 8 Code 128 Cm j Send from Script Z9 9 Ma...

Page 118: ...ollowing illustration shows the breakdown of a message string Points to Keep In Mind It is not necessary to customize the message string The selections in this chapter are only used if you wish to alter the default settings Default prefix None Default suffix CR If desired each decoded symbology may be assigned a unique prefix and suffix You can add any prefix or suffix from the ASCII chart page 5 ...

Page 119: ...h scan 5 C 5 C Step 8 Scan Save to exit and save or scan Discard to exit without saving Repeat Steps 1 6 to add a prefix or suffix for another symbology Example Add a Suffix to a specific symbology To send a CR carriage return Suffix for UPC only Step 1 Scan Add Suffix Step 2 Determine the 2 digit hex value from the Symbology Chart page 5 19 for UPC Step 3 Scan 6 3 from the Programming Chart insid...

Page 120: ...value from the Programming Chart inside the back cover or scan 9 9 for all symbologies Your change is automatically saved Prefix Selections Suffix Selections 1 One or more two digit numbers and Save are required after scanning this programming bar code Refer to the Programming Chart inside back cover Add Prefix1 Default Prefix none Clear One Prefix1 Clear All Prefixes Add Suffix1 Default Suffix CR...

Page 121: ... Interleaved 2 of 5 e 65 EAN UCC Composite y 79 Code 2 of 5 IATA with 2 bar start stop patterns f 66 China Post Code q 71 Code 2 of 5 Industrial with 3 bar start stop pat terns f 66 Keypad Input k 6B Code 11 h 68 Host Command Response 7 37 Code 93 i 69 Host Input 8 38 Code 128 j 6A Send from Script1 1 Send from Script does not allow any prefix suffix to be appended regardless of the settings or th...

Page 122: ...n Off The following selections allow you to turn on and off the prefix and suffix formatting These codes are used when you want to toggle between turning on and off the prefix and suffix formatting Suffix On Off On Off On Off ...

Page 123: ... K 107 6B k 12 0C FF 44 2C 76 4C L 108 6C l 13 0D CR 45 2D 77 4D M 109 6D m 14 0E SO 46 2E 78 4E N 110 6E n 15 0F SI 47 2F 79 4F O 111 6F o 16 10 DLE 48 30 0 80 50 P 112 70 p 17 11 DC1 49 31 1 81 51 Q 113 71 q 18 12 DC2 50 32 2 82 52 R 114 72 r 19 13 DC3 51 33 3 83 53 S 115 73 s 20 14 DC4 52 34 4 84 54 T 116 74 t 21 15 NAK 53 35 5 85 55 U 117 75 u 22 16 SYN 54 36 6 86 56 V 118 76 v 23 17 ETB 55 37...

Page 124: ...at See page 5 27 If you are programming the primary format scan 0 If you are programming an alternate format scan 1 2 or 3 depending on the alternate format you are programming Step 3 Terminal Type Refer to the Supported Terminals Chart page 2 6 and locate the Terminal ID number for your PC Scan 3 numeric bar codes on the inside back cover to program the scanner for your terminal ID you must enter...

Page 125: ...nversion chart page 5 21 F3 Send up to but not including ss character Search and Send starting from current cursor position leaving cursor pointing to ss character followed by xx key or function code Syntax F3ssxx ss and xx both stand for the hex values for ASCII codes see Decimal to Hex to ASCII Conversion chart page 5 21 F4 Send xx character nn times Insert leaving cursor in current cursor posi ...

Page 126: ...ersion chart page 5 21 FC Disable suppress filter and clear all suppressed characters Syntax FC EB Toggles the auxiliary port on and off This command is used when data is normally transmitted out the main port and needs to be temporarily sent out the aux port The first EB in a format string opens the aux port temporarily re directing data transmission out the aux port Send commands F1 F2 F3 F4 are...

Page 127: ...at selections and commands Data Formatter When Data Formatter is turned off the bar code data is output to the host as read including prefixes and suffixes Enter Data Format Default Data Format Clear One Data Format Save Clear All Data Formats Discard Data Formatter On Data Formatter Off ...

Page 128: ...atter is required all input data must conform to an edited format or the base does not transmit the input data to the host device If this occurs the scanner triple beeps and the data is discarded Data Format Required Data Format Not Required ...

Page 129: ...he format requirements Should you also want the scanner to beep when a bar code has been successfully read and sent to the host from the base turn the Decode Beep Selection on Alternate Data Formats Alternate formats allow you single shot capability to scan one bar code using a different data format than your primary format When data formats are programmed see page 5 22 you must input whether you ...

Page 130: ...5 28 ...

Page 131: ...section contains the following menu selections Programming Tip If a symbology will not be used we recommend turning it off to maximize decoding speed and security Codabar Telepen Code 39 China Post Code Code 93 Reduced Space Symbology RSS Interleaved 2 of 5 PDF417 Code 2 of 5 MicroPDF417 Matrix 2 of 5 EAN UCC Composite Symbology Code 11 EAN Code 128 UPC ...

Page 132: ...6 2 Codabar Default All Codabar Settings Codabar Start Stop Characters On Off Transmit Don t Transmit ...

Page 133: ...MPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover Minimum and Maximum...

Page 134: ...cification Codabar for more information Concatenation Codabar supports symbol concatenation When you turn concatenation on the reader will look for a Codabar symbol having a D start character adjacent to a symbol having a D stop character In this case the two messages are concatenated into one with the D characters omitted Select Require to prevent the reader from decoding a lone Codabar symbol No...

Page 135: ...6 5 Codabar continued Concatenation Concatenation Not Allowed Concatenation Allowed But Not Required Concatenation Required ...

Page 136: ...6 6 Code 39 Default All Code 39 Settings Code 39 Start Stop Characters On Off Transmit Don t Transmit ...

Page 137: ...MPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover Minimum and Maximum...

Page 138: ...ate whether the check character was encoded the reader cannot autodiscriminate Therefore the reader must be configured if it is to perform check character validation Refer to AIM Uniform Symbology Specification Code 39 for more information No Check Character Encoded Validate and Transmit Check Character Validate but Don t Transmit Check Character ...

Page 139: ... SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D 4 4 D D T T d D t T ENQ E NAK U E 5 5 E E U U e E u U ACK F SYN V F 6 6 F F V V f F v V BEL G ETB W G 7 7 G G W W g G w W BS H CAN X H 8 8 H H X X h H x X HT I EM Y I 9 9 I I Y Y i I y Y LF J SUB Z J Z J J Z Z j J z Z VT K ESC A K F K K K k K P FF L FS B L G L ...

Page 140: ...nabled the scanner stores those Code 39 bar codes that start with a space excluding the start and stop symbols and does not immediately transmit the data The scanner stores the data in the order in which the bar codes are read deleting the first space from each The scanner transmits the appended data when it reads a Code 39 bar code that starts with a character other than a space Default Off On Of...

Page 141: ...6 11 Code 93 Default All Code 93 Settings Code 93 On Off ...

Page 142: ...AMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover Minimum and Maximu...

Page 143: ...6 13 Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings Interleaved 2 of 5 On Off ...

Page 144: ... misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover Minimum...

Page 145: ... means to indicate whether the check digit was encoded the reader cannot autodiscriminate Therefore the reader must be configured if it is to perform check digit validation Refer to AIM Uniform Symbology Specification Interleaved 2 of 5 for more information No Check Digit Encoded Validate and Transmit Check Digit Validate but Don t Transmit Digit ...

Page 146: ...6 16 Code 2 of 5 Default All Code 2 of 5 Settings Code 2 of 5 On Off ...

Page 147: ...d EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover Minimum and Ma...

Page 148: ...6 18 Matrix 2 of 5 Default All Matrix 2 of 5 Settings Matrix 2 of 5 On Off ...

Page 149: ...ead EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover Minimum and ...

Page 150: ...6 20 Code 11 Default All Code 11 Settings Code 11 Code 11 Check Digits Required On Off 2 Check Digits 1 Check Digit ...

Page 151: ...AMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover Minimum and Maximu...

Page 152: ...6 22 Code 128 Default All Code 128 Settings Code 128 On Off ...

Page 153: ...e only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover Minimum length range 0 80 and...

Page 154: ...hat occur in the first or second symbol position Default On ISBT 128 The International Society of Blood Transfusion ISBT ratified a new standard in 1994 for communicating critical blood information in a uniform manner The ISBT 128 Application Specification describes 1 the critical data elements for labeling blood products 2 the current recommendation to use Code 128 due to its high degree of secur...

Page 155: ...6 25 Telepen Default All Telepen Settings Telepen On Off ...

Page 156: ...ar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover Minimum and Maximum lengths 1 60 Defaults are Minimum 1 Maximum 60 If you make an error while scanning the digits before scanning Save scan...

Page 157: ...6 27 China Post Code IT3870 IT3875 only Default All China Post Code Settings China Post Code On Off ...

Page 158: ...s of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover M...

Page 159: ...ology RSS is a family of linear bar codes that meets restricted space requirements while still providing full product identification RSS Limited IT3870 IT3875 only RSS Expanded IT3870 IT3875 only Default All RSS Expanded Settings On Off On Off On Off ...

Page 160: ...a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover Minimu...

Page 161: ...6 31 PDF417 IT3870PDF IT3875PDF only Default All PDF417 Settings PDF417 On Off ...

Page 162: ...Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover Minimum length range 1 1...

Page 163: ...ifier GLI feature of PDF417 This mode is recommended when the host system is capable of interpreting the GLI Block and capable of performing the new interpretation The GLI Block may occur anywhere in the data and begins with the escape character ASCII 5C hex Any natural occurrence of the in data is replaced by When this feature is disabled the GLI Blocks are not transmitted Default Don t Show GLI ...

Page 164: ...ol Blocks Turning on this feature causes the Macro PDF Control Block to be transmitted at the end of the encoded data except when the reader has successfully buffered and assembled each symbol into a single message The Control Block is transmitted as defined in AIM Uniform Symbology Specification PDF417 using an escape sequence The Control Block begins with the escape character ASCII 5C hex and an...

Page 165: ...o read each code PDF 417 x rows x cols xx data xx chks ECL x UEC xxx Rows Number of rows Cols Number of columns Data Number of data words Chks Number of check words ECL Error Correction Level UEC Unused Error Correction PDF417 Learn Mode This setting tells the scanner to brighten the LED s when you have an optimal distance between the scanner and the PDF417 code you are attempting to read Reading ...

Page 166: ...6 36 MicroPDF417 IT3870PDF IT3875PDF only Default All MicroPDF417 Settings MicroPDF417 On Off ...

Page 167: ...of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover Min...

Page 168: ...r codes are combined with a unique 2D composite component to form a new class called EAN UCC Composite Symbology EAN UCC Composite Symbology allows for the co existence of symbologies already in use Enable UPC EAN Version Turn on this selection to decode EAN UCC composite symbols having a UPC or EAN primary component On Off On Off ...

Page 169: ...es of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes below then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover ...

Page 170: ...6 40 EAN JAN 8 Default All EAN JAN 8 Settings EAN JAN 8 EAN JAN8 Check Digit On Off Transmit Don t Transmit ...

Page 171: ...6 41 EAN JAN 13 Default All EAN JAN 13 Settings EAN JAN 13 EAN JAN13 Check Digit ISBN This symbology allows the scanner to read ISBN codes on books On Off Transmit Don t Transmit On Off ...

Page 172: ...6 42 UPC A Default All UPC A Settings UPC A Note UPC will be transmitted as EAN if UPC is off UPC is a subset of EAN To disable UPC it is necessary to disable both UPC and EAN symbologies On Off ...

Page 173: ...6 43 UPC A continued UPC A Check Digit Number System Transmit Don t Transmit Transmit Don t Transmit ...

Page 174: ...6 44 UPC E0 Default All UPC E0 Settings UPC E0 UPC E0 Check Digit Number System On Off Transmit Don t Transmit Transmit Don t Transfer ...

Page 175: ...6 45 UPC E0 continued Version E Expand UPC E1 UPC E1 is no longer recommended for use by the Uniform Code Council UCC Expand Don t Expand On Off ...

Page 176: ...6 46 EAN UPC Addenda EAN Addenda Require Don t Require Two Digit Addenda On Two Digit Addenda Off Five Digit Addenda On Five Digit Addenda Off ...

Page 177: ...6 47 UPC Addenda Two Digit Addenda On Two Digit Addenda Off Five Digit Addenda On Five Digit Addenda Off ...

Page 178: ...6 48 ...

Page 179: ...rt to the device If you need to connect to the base and reflash the base s software you need a power supply and a RS 232 aux port download cable To reflash software in the IT3870 IT3875 ST5770 you need a power supply and a 3870 75 5770 download cable Note The IT3875 and ST2070 5 require Visual Menu revision 3 5 or later Visual Menu Operations The Visual Menu program performs the following operatio...

Page 180: ...t to the Visual Menu executable on your desktop IQ App Loader IT3875XXX X2 1 and ST2070 5only IQ App Loader is a PC tool that takes script applications you create in a text editor and compiles and loads them into the ST2070 base Please refer to the VersaCode Language Reference User s Guide for additional information Installing IQ App Loader from the Web 1 Access the HHP web site at www hhp com 2 C...

Page 181: ...for rapid development with minimal programming experience Please refer to the IQ App Designer User s Guide for additional information about the program For information about purchasing IQ App Designer please contact your HHP Representative or your local distributor IQ Editing Pro IQ Editing Pro is a feature of IQ App Designer that eases the transition to 2D bar codes e g PDF417 and MicroPDF417 IQ ...

Page 182: ...7 4 ...

Page 183: ...terminals that can be used with the Cordless System Function Code HEX ASCII Value Full ASCII CTRL NUL 00 2 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS 1D RS 1E 6 US 1F ...

Page 184: ...ply to US only The following chart indicates the equivalents of these five characters for different countries Country Codes United States 6 Belgium 6 Scandinavia 8 9 6 France 8 6 Germany à 6 Italy 6 Switzerland 6 United Kingdom 6 Denmark 8 9 6 Norway 8 9 6 Spain 6 ...

Page 185: ... Line BS 08 Reserved Reserved F16 HT 09 Tab Tab F17 LF 0A Reserved Reserved F18 VT 0B Tab Tab Tab Field Forward FF 0C Delete Delete Delete CR 0D CR Enter CR Enter Field Exit New Line SO 0E Insert Insert Insert SI 0F Escape Escape F19 DLE 10 F11 Reserved Error Reset DC1 11 Home Home Home DC2 12 Print Print F20 DC3 13 Back Space Back Space Back Space DC4 14 Back Tab Back Tab Backfield Back Tab NAK 1...

Page 186: ...F18 F13 F11 VT 0B Tab Field Forward F14 F12 FF 0C Delete Remove Delete Character CR 0D Field Exit New Line Carriage Return SO 0E Insert Insert Here Insert SI 0F Clear Cursor Up Clear DLE 10 Error Reset Cursor Left Error Reset DC1 11 Home Cursor Down Home DC2 12 Print Cursor Right Delete Line DC3 13 Back Space Delete Erase EOP DC4 14 Back Tab Print Erase EOF NAK 15 F19 F15 Insert Line SYN 16 F1 F1 ...

Page 187: ...7 New LIne Return BS 08 Replace PF4 Reserved HT 09 Tab Forward Tab LF 0A F13 Line Feed VT 0B F14 Reserved FF 0C F15 Reserved CR 0D New Line Carriage Return SO 0E Insert Reserved SI 0F Cursor Up Cursor Up DLE 10 Cursor Left Cursor Left DC1 11 Cursor Down Cursor Down DC2 12 Cursor Right Cursor Right DC3 13 Back Space Back Space DC4 14 Print Reserved NAK 15 F16 Reserved SYN 16 F1 F1 ETB 17 F2 F2 CAN ...

Page 188: ...8 6 ...

Page 189: ... Consumption Standard Mode 285 mA typical 5 VDC Low Power Mode 140 mA typical 5 VDC Noise Immunity 100 mV peak to peak Temperature Ranges Operating 4 F to 122 F 20 C to 50 C Storage 40 F to 158 F 40 C to 70 C Humidity 0 to 95 relative humidity non condensing Housing Material GE Cycloloy C2800 or C2950 Standard Flow Sealing IP 53 Water and Dust Resistant Mechanical Shock 26 drops from 4 feet 1 2 m ...

Page 190: ...cations Parameter Specification Frequency 2 400 to 2 4835 Ghz ISM Band Frequency Hopping Spread Spectrum Data Rates 1 Mbps Response Time Standard Mode 10 mS Typical Low Power Mode 65 mS Typical of co existing systems 20 ...

Page 191: ...olume and tone programmable Power Consumption Operating 425 mA max while scanning Standby 20 mA typical Battery Conservation Mode 10 mA typical Ambient Light Total darkness to 100 000 Lux sunlight Temperature Ranges Operating 32 F to 122 F 0 C to 50 C Storage 22 F to 140 F 30 C to 60 C Humidity 5 to 95 relative humidity non condensing Altitude Sea level to 9 900 feet 3000 meters Housing Material G...

Page 192: ...mmable Power Consumption Operating 425 mA max while scanning 505 mA max with backlight on Standby 25 mA typical while scanning 100 mA typical with backlight on Battery Conservation Mode 15 mA typical Ambient Light Total darkness to 100 000 Lux sunlight Temperature Ranges Operating 32 F to 122 F 0 C to 50 C Storage 22 F to 140 F 30 C to 60 C Humidity 5 to 95 relative humidity non condensing Altitud...

Page 193: ...cular 5770ALR Pitch Angle 55 degrees left right from perpendicular 5770STD 65 degrees left right from perpendicular 5770ALR Operating Voltage 4 3 to 6 0 VDC Power Consumption Operating 400 mA maximum 4 8 VDC Standby 21 mA Battery Conservation Mode 4 mA Ambient Light Total darkness to 100 000 Lux sunlight Temperature Ranges 5770STD 5770ALR Operating 4 F to 122 F 20 C to 50 C Storage 22 F to 158 F 3...

Page 194: ...acity and is conditioned for full capacity and longer life See Charge Pack Recommendations on page 1 4 Recommended Storage Note When storing a charge pack for longer than 6 months recharge at least once a year once every 6 months if possible to prevent self discharge from causing a drop in battery performance or electrolyte leakage Parameter Specification Number of scans between charges IT3870 ST5...

Page 195: ...9 7 Connectors Pinouts Keyboard Terminal and RS 232 Connector Host Port External Power Connector Aux RS 232 Service Port and Wand Emulation Output Connector Cordless Base Back View ...

Page 196: ...l output wand emulation data on Pin 7 at the selected rates polarity described on page 2 12 or in the Plug and Play section page 2 2 Start Bit 1 Data Bits 7 or 8 Stop Bits 1 or 2 Parity None Mark Space Odd or Even Baud Rate 300 600 1200 2400 4800 9600 19200 38400 The auxiliary RS 232 scanner connector supports wand emulation or the attachment of an RS 232 input device The Aux port is compatible wi...

Page 197: ... by using the System Manual Chapters 2 through 4 Output Parameters General Operating and Symbology Menus Keyboard Terminal and RS 232 Host Port Connector DB 15 Pin Female Power Signal Ground 1 5 Volt DC Power In 2 RS 232 Receive Data input 3 RS 232 Clear to Send input 4 Keyboard Data from Keyboard 5 Keyboard Clock from Keyboard 6 WYSE 7 IBM 4683 8 9 High Voltage Power input maximum 14 VDC 10 MCU B...

Page 198: ...xternal power supply or from the terminal to which the Base is connected External power is provided through a two position barrel type connector on the Base s back panel The input voltage range is 4 VDC to 14 VDC and the schematic diagram is shown below Ground 9 Volts DC example ...

Page 199: ...9 11 Cordless Base Dimensions ST2070 Front View 1 4 in 3 6 cm Top View 4 5 in 11 5 cm 4 0 in 10 2 cm 3 4 View Side View ...

Page 200: ...9 12 Cordless Scanner Dimensions IT3870 5 801 14 74 4 707 11 96 3 201 8 13 1 648 4 19 8 484 21 55 1 858 4 72 3 4 View Top View Front View Side View ...

Page 201: ...9 13 Cordless Scanner Dimensions IT3875 3 4 View Top View Front View Side View 5 930 in 15 06 cm 4 835 in 12 28 cm 1 870 in 4 75 cm 8 722 in 22 2 cm 1 858 in 4 72 cm 3 197 in 8 12 cm ...

Page 202: ...9 14 Cordless Scanner Dimensions ST5770 3 4 View Top View Front View 6 00 in 15 24 cm 4 72 in 11 99 cm 3 06 in 7 77 cm 1 45 in 3 68 cm 8 28 in 21 03 cm 1 86 in 4 72 cm Side View ...

Page 203: ...0 C for IMAGETEAM 3870HD and IMAGETEAM 3875HD measured in inches 4 0 10 2 3 0 7 6 2 0 5 1 1 0 2 5 0 0 0 0 1 0 2 5 2 0 5 1 3 0 7 6 4 0 10 2 In Cm In 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 Cm 0 0 2 5 5 1 7 6 10 2 12 7 15 2 17 8 20 3 3 mil 5 mil 7 5 mil 13 mil ...

Page 204: ...75LX Measured in inches In Cm 4 0 10 2 3 0 7 6 2 0 5 1 1 0 2 5 0 0 0 0 1 0 2 5 2 0 5 1 3 0 7 6 4 0 10 2 In 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 11 12 13 14 15 16 17 18 Cm 0 0 2 5 5 1 7 6 10 2 12 7 15 2 17 8 20 3 22 9 25 4 27 9 30 5 33 35 6 38 1 40 6 43 2 45 7 7 5 mil 13 mil 6 5 mil 15 mil ...

Page 205: ...AGETEAM 3870PDF and IMAGETEAM 3875PDF Linear Measured in inches 3 0 7 6 2 0 5 1 1 0 2 5 0 0 0 0 1 0 2 5 2 0 5 1 3 0 7 6 In Cm In 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 Cm 0 0 2 5 5 1 7 6 10 2 12 7 15 2 17 8 20 3 22 9 5 mil 7 5 mil 13 15 mil ...

Page 206: ...at 20 C for IMAGETEAM 3870PDF417 and IMAGETEAM 3875PDF417 Measured in inches 3 0 7 6 2 0 5 1 1 0 2 5 0 0 0 0 1 0 2 5 2 0 5 1 3 0 7 6 In Cm n 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 m 0 0 2 5 5 1 7 6 10 2 12 7 15 2 17 8 20 3 22 9 6 7 mil 10 mil 15 mil ...

Page 207: ...meters 7 28 20 14 3 5 34 In Cm 8 20 32 0 0 8 20 32 3 6 5 mil 7 5 mil 6 1 9 2 In Cm 0 0 5 12 7 10 25 4 15 38 1 20 50 8 25 63 5 30 76 2 40 mil 28 0 3 2 ACAP 20 mil 20 0 ACAP 35 88 9 12 30 48 4 10 16 12 30 48 4 10 16 55 mil 34 0 ACAP 13 mil 14 0 ACAP ACAP As close as possible Width of Field in Inches Centimeters ...

Page 208: ...00 330 360 76 2 152 4 228 6 304 8 381 0 457 2 533 4 609 6 685 8 762 0 838 2 914 4 IN Cm 41 104 1 30 76 2 20 50 8 10 25 4 0 0 10 25 4 20 50 8 30 76 2 41 104 1 W ID T H O F F IE LD IN IN C H E S C E N T IM E T E R S TYPICAL PERFORMANCE AT 20 C FOR SCANTEAM 5770 ALR 15 MIL 22 43 30 MIL 40 88 55 MIL 25 99 123 100 MIL 322 ...

Page 209: ...rs Inspect the cordless base s interface cable and connector for wear or other signs of damage A badly worn cable or damaged connector may interfere with operation Contact your Hand Held Products distributor for information about cable replacement Cable replacement instructions are on page 10 2 Examining the Cordless Scanner and Cordless Base Housings Routinely examine the cordless scanner and cor...

Page 210: ...se a 10 position modular plug To remove the Aux Port cable depress the dimple located on the bottom of the base unit underneath the Aux Port and pull the cable from the unit Note Order replacement cables from Hand Held Products or from an authorized distributor When ordering a replacement cable specify the cable part number of the original interface cable Recharging and Replacing the Cordless Scan...

Page 211: ... 3 the bar code symbology is enabled see Chapter 6 Symbology Menu 4 the cordless scanner window is clean Is the bar code displayed but not entered The bar code is displayed on the host device correctly but you still have to press a key to enter it the Enter Return key or the Tab key for example You need to program a suffix Programming a suffix enables the cordless system to output the scanned bar ...

Page 212: ...of this manual If the cordless system reads the Sample Bar Codes check that your bar code is readable See Is the cordless system having trouble reading your bar codes on page 10 3 Verify that your bar code symbology is enabled See Chapter 5 Symbology Menu If the cordless system does not read the Sample Bar Codes either continue to 2 below 2 If the cordless system won t read the Sample Bar Codes ei...

Page 213: ...fore returning the product HHP Service Department 7510 E Independence Blvd Suite 200 Charlotte NC 28227 Telephone 800 782 4263 Fax 704 566 9904 For service in Europe please contact your HHP representative at the address that follows or your local distributor European Office Hand Held Products Inc Nijverheidsweg 9 5627 BT Eindhoven The Netherlands Telephone 31 0 40 29 01 600 Fax 31 0 40 24 25 672 U...

Page 214: ...e address that follows or your local distributor Japan Office Hand Held Products Inc Bon Marusan 8F 3 5 1 Kanda Jinbocho Chiyoda ku Tokyo 101 Japan Telephone 81 3 5212 7392 Fax 81 3 3261 7372 For service in Latin America please contact your HHP representative at the address that follows or your local distributor Latin America Office Hand Held Products Inc 5117 Castello Drive Suite 1 Naples FL 3410...

Page 215: ...hone 315 685 2476 8 a m to 6 p m EST or in the U S 800 782 4263 Fax number 315 685 4960 E mail tech_support hhp com Europe Telephone European Ofc Int 31 40 242 4486 U K Ofc Int 44 1925 240055 E mail euro_support hhp com Asia Telephone Int 852 2511 3050 or 2511 3132 E mail asia_support hhp com Latin America Telephone 56 2 942 2495 or 56 2 942 8371 E mail la_support hhp com ...

Page 216: ...Warranty Period and HHP determines to its satisfaction that the product is defective due to defects in materials or workmanship HHP at its sole option will either repair or replace the product without charge except for return shipping to HHP EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES EITHER EXPRESSED OR IMPLIED ORAL ...

Page 217: ...11 5 Limited Warranty Durations IT3870 3875 ST5770 ST2070 CLESS NIMH S Charge Pack 3 Years 3 Years 3 Years 1 Year ...

Page 218: ...11 6 ...

Page 219: ...board Style Modifiers Control ASCII Mode Off 2 10 Turbo Mode Off 2 10 Numeric Keypad Mode Off 2 10 Auto Direct Connect Off 2 11 Output Delays Intercharacter Delay 00 x5mS 2 11 Interfunction Delay 00 x5mS 2 11 Intermessage Delay 00 x5mS 2 11 Wand Emulation Selections Transmission Rate 25 ips 2 12 Output Polarity Black High 2 13 Power Settings Base Low Power Mode Off 2 14 Battery Conservation Mode N...

Page 220: ... 12 Word Length Stop Bits 1 3 13 Hardware Flow Control Off 3 13 Protocol Record 3 16 Data Character SOR Start of Record 00 NUL 3 17 EOR End of Record 0D CR 3 17 SOB Start of Block 00 NUL 3 17 EOB End of Block 04 EOT 3 17 Aux Prefix Suffix Aux Prefix Incoming Data None 3 18 Aux Suffix Incoming Data None 3 18 Aux Prefix Outgoing Data None 3 18 Aux Suffix Outgoing Data CR 3 18 Aux Prefix On Off On 3 ...

Page 221: ...ish 5 10 Beeper Volume High 5 11 Beeper Pitch Medium 5 11 Scanner Voting Voting Normal 5 12 Laser Marker Beam Off 5 13 AIM I D Prefix Off 5 13 Code I D Prefix Off 5 14 Prefix Suffix Selections Prefix None 5 18 Suffix CR 5 18 Prefix On Off On 5 20 Suffix On Off On 5 20 Data Formatter Selections Data Formatter On 5 25 Require Data Format Not Required 5 26 Decode Beep Off 5 27 Codabar Selections Coda...

Page 222: ...cter No Check Character Encoded 6 8 Full ASCII On 6 9 Append Off 6 10 Code 93 Selection Code 93 On 6 11 Code 93 Message Length Min 0 Max 64 6 12 Interleaved 2 of 5 Selection Interleaved 2 of 5 On 6 13 Interleaved 2 of 5 Message Length Min 4 Max 80 6 14 Check Digit No Check Digit Encoded 6 15 Code 2 of 5 Selection Code 2 of 5 On 6 16 Code 2 of 5 Message Length Min 4 Max 80 6 17 Matrix 2 of 5 Select...

Page 223: ...en On 6 25 Telepen Message Length Min 1 Max 60 6 26 Telepen Output Numeric Only 6 26 China Post Code Selection IT3870 IT3875 only China Post Code Off 6 27 China Post Code Message Length Min 4 Max 80 6 28 RSS 14 Selection IT3870 IT3875 only RSS 14 Off 6 29 RSS Limited Off 6 29 RSS Expanded Off 6 29 RSS Message Length Min 4 Max 74 6 30 PDF417 Selection IT3870PDF IT3875PDF only PDF417 On 6 31 PDF417 ...

Page 224: ...h Min 1 Max 366 6 37 EAN UCC Composite Symbology Selection IT3870PDF IT3875PDF only EAN UCC Composite Symbology Off 6 38 Enable UPC EAN Version Off 6 38 EAN UCC Composite Symbology Message Length Min 1 Max 2400 6 39 EAN JAN 8 Selection EAN JAN 8 On 6 40 Check Digit Transmit 6 40 EAN JAN 13 Selection EAN JAN 13 On 6 41 Check Digit Transmit 6 41 ISBN Off 6 41 UPC A Selection UPC A On 6 42 Check Digi...

Page 225: ... 44 Version E Expand Don t Expand 6 45 UPC E1 Selection UPC E1 Off 6 45 EAN UPC Addenda Selection EAN UPC Addenda Don t Require 6 46 EAN Two Digit Addenda Off 6 46 EAN Five Digit Addenda Off 6 46 UPC Two Digit Addenda Off 6 47 UPC Five DIgit Addenda Off 6 47 Parameter Default Setting Page ...

Page 226: ...12 8 ...

Page 227: ......

Page 228: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 Code 39 Codabar 1234567890 Code 128 9 780330 290951 BC321 A13579B Code 11 with 2 Check Characters 0123456789 ...

Page 229: ...Test Message Matrix 2 of 5 6543210 Code 93 123456 9 Code 2 of 5 123456 MicroPDF417 MicroPDF417 Test Message RSS 14 01 00123456789012 EAN UCC Composite 01 12345678901231 10 123456789 11 001205 3202 001234 Symbology with RSS Limited ...

Page 230: ...numeric bar codes used for setting additional programming options such as the digits representing Symbology Message Length Scan the programming selection bar code first and then scan the bar code s representing the option you want to set 0 2 6 1 7 5 4 3 8 9 ...

Page 231: ...Programming Chart A C Save B Discard Current Changes F E D ...

Page 232: ...3870 75 5770 SM Rev C ...