User Manual RDx-AC-xxxDT-10.31
Page 4 of 13
www.hanbayinc.com | 1 800 315 4461
Rev.2021.9 [email protected]
Power Supply and Current Draw
The
RDx-AC-xxxDT
actuator
may be connected to voltages ranging
within 110-240 VAC.
The current draw will range from minimum 10 mA to maximum 1.5 A while
the actuator is active. When not moving, the actuator draws approx. 5 mA.
AC power is connected to the
WHITE
&
BLACK
wires with crimp
connectors (WM18225-DN & WM18230-ND 18-22 AWG).
Ground is connected on the
GREEN
ground screw, shown below.
Control Signal and Feedback
Locate the correct connection terminals/wires, as shown on the previous page, then connect your input
signal on positions 1 and 2 (blue and yellow wires) as shown below. Feedback, if applicable is connected to
positions 3 and 4 (grey and green wires).
AC Input
Black
– Live
White
– Neutral
Internal Wires for 24 VDC
(Already Connected)
White
+24 VDC
Black
0 VDC
Ground Connection
AC Voltages
AC Gnd common to PWR Gnd
1 2 3 4 5 6
P1
Input #1
TTL I/O Signals
Input #2
Output #2
Output #1
USER SUPPLIED
GND
RL
(max. drive
current 2.5 mA,
optionally up to
1 A)
External
I/O device
supplied by
user
< 1mA
RDx-AC-xxxDT
Internal
Actuator