RDF-AC-xxxDT models

 

 
 

 

 

Summary of Contents for RD-AC Series

Page 1: ... Rated USER MANUAL Contents INSTALLATION 2 Mounting 2 Wiring 2 Wiring for Explosion Proof Actuators 2 Wiring for Non Explosion Proof actuators 3 Power Supply and Current Draw 4 Control Signal and Feedback 4 OPERATION 5 DIP Switches 5 Functionality 6 Calibration 7 Manual Override 7 Troubleshooting 8 EXPLOSION PROOF CERTIFICATIONS 8 ACTUATOR DIMENSIONS 9 PART NUMBER BREAKDOWN 11 LABEL BREAKDOWN 13 ...

Page 2: ...location should be installed by qualified personnel in accordance with site and local requirements The actuator comes standard with a FNPT thread cable entry See p 9 for location of FNPT housing access A cable with 7 wires is required it is recommended to use 3x 16 AWG for wires supplying power and ground and 4x 20 AWG for wires used for the control and feedback signals Standards for cable gland a...

Page 3: ...cable to the length required then connect according to the following wire color schematic Wire color schematic for cable Pin Function 6 Already connected to power supply connect live wire to loose black cable with crimp connector see p 4 5 Already connected to power supply connect neutral wire to loose white cable with crimp connector see p 4 4 Output TTL2 3 Output TTL1 2 Input TTL2 1 Input TTL1 C...

Page 4: ...onnected on the GREEN ground screw shown below Control Signal and Feedback Locate the correct connection terminals wires as shown on the previous page then connect your input signal on positions 1 and 2 blue and yellow wires as shown below Feedback if applicable is connected to positions 3 and 4 grey and green wires AC Input Black Live White Neutral Internal Wires for 24 VDC Already Connected Whit...

Page 5: ...he valve at the factory Worn in valves may require a higher torque setting after some time The actuator will use 100 of available torque to try and reach maximum speed DIP 1 DIP 2 Description Recommended Use Off Off Fastest settling Use only for low torque valves Off On Medium fast Typical setting On Off Medium slow Typical setting On On Slowest settling Use for high torque valves DIP 10 DIP 11 To...

Page 6: ...ne and then move to the position commanded by the input signals DIP 12 DIP 12 sets the direction of rotation Functionality The RDx can operate as a 3 position or 4 position actuator The 4th position is enabled by turning DIP 8 ON Note that inputs 1 2 pins 1 2 are HIGH by default a LOW signal must be sent to change the value Sending a HIGH signal may be harmful to the internal circuit board 3 pos F...

Page 7: ... actuated This does not happen on input 2 Calibration The center position calibration routine can be initiated by switching DIP 9 momentarily off then on This will cause the actuator to go through a series of movements to determine the proper center position This function is useful if the actuator s output gear gets manually rotated while the actuator is powered down and can t properly realign to ...

Page 8: ...king valve may be the problem Remove the valve from the actuator and re test the actuator 3 Remove power Re check the wiring and the power signal apparatus Power actuator and re calibrate If the problem persists please call Hanbay for technical support EXPLOSION PROOF CERTIFICATIONS Actuator model number RDx BxxDT IECEX Standards Editions IEC 60079 0 2017 7th Edition IEC 60079 1 2014 7th Edition S...

Page 9: ...User Manual RDx AC xxxDT 10 31 Page 9 of 13 www hanbayinc com 1 800 315 4461 Rev 2021 9 hanbaysales hanbayinc com ACTUATOR DIMENSIONS RDL RDM AC xxxDT models ...

Page 10: ...User Manual RDx AC xxxDT 10 31 Page 10 of 13 www hanbayinc com 1 800 315 4461 Rev 2021 9 hanbaysales hanbayinc com RDH AC xxxDT models ...

Page 11: ...User Manual RDx AC xxxDT 10 31 Page 11 of 13 www hanbayinc com 1 800 315 4461 Rev 2021 9 hanbaysales hanbayinc com RDF AC xxxDT models ...

Page 12: ...igh Torque Add Gear Stage DC Continuous TTL Input Board F Higher Torque Add Gear Stage DT TTL Input Board with Integrated Feedback AS Modbus Control with Feedback PT Propane Board Limit Switches Thermal Cut Off 0 No Option H Internal Heater F External Fan 0 Cable Gland Specify Cable length at added cost 4 Custom Dual Guage Cable 10ft 5 TURCK 5 Position Connector w 20 Cable and Plug 6 TURCK 6 Posit...

Page 13: ...or Part Number Refer to part number breakdown for available options Ex proof Certification Info on ex proof ratings and installation instructions Actuator Serial Number This serial number is unique for each individual unit and is directly tied to your order invoice number Firmware Version AF 1 05 MM Multiturn AB 1 05 MML Multiturn Low Torque AS 1 05 MMUL Multiturn Extra Low Torque QM Quarter turn ...

Reviews: