EN
10
• EMC certified (R10)
• Integrated DT connector
PARTS
1. Light source
2. Socket, light source
3. Socket, power cord
4. Wire, white
5. Switch
6. Wire, blue
7. Fuse 15 A
8. Wire, red
9. Battery
10. Wire, black
11. Relay, 12/24 VDC
FIG. 1
INSTALLATION
Accessories for installation included.
FIG. 2
1. Drill a screw hole with a diameter of
11 mm in the surface where the product
is to be installed.
2. Put the screw in the hole, put on the lock
washer and tighten the nut.
FIG. 3
NOTE:
• Disconnect the negative/chassis earth
cable from the battery before connecting
the product, to avoid damage from
short-circuiting during the installation.
• Follow as far as possible the existing
cable routing for installation of new
cables.
• Carefully fasten the cable and any excess
length with cable ties, insulating tape or
the equivalent.
SAFETY INSTRUCTIONS
• Read these instructions carefully before
installation and save them for future
reference.
• Always comply with the applicable laws
and regulations for the installation and
use of auxiliary headlights.
SYMBOLS
Read the instructions.
Approved in accordance with
the relevant directives.
Recycle discarded product
in accordance with local
regulations.
TECHNICAL DATA
Rated voltage
12/24 VDC
Rated current at 12 V
4.2 A
Rated current at 24 V
2.1 A
Light source
9 x 10 W LP LED
Output 90 W
Luminous flux
9500 lm
Beam 120°
DESCRIPTION
Powerful work light for installation on vehicles
such as tractors, trucks, excavators etc.
FEATURES
• Angled lamp housing in three steps
• Diffuse beam – wide light from start
• Jet-proof and robust aluminium housing
• Polycarbonate lens
• Waterproof and withstands high-pressure
washing