CAUTIONS

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety 

precautions should always be followed including the 

following:

READ AND FOLLOW ALL 

SAFETY INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before 

installation.

DANGER

 – Risque de choc – Couper l’alimentation 

avant l’installation.

2.  This Product Must Be Installed In Accordance With The 

Applicable Installation Code By A Person Familiar With 

The Construction And Operation Of The Product And The 

Hazards Involved. 

Ce Produit Doit Être Installé Selon Le Code D’installation 

Pertinent, Par Une Personne Qui Connaît Bien Le 

Produit Et Son Fonctionnement Ainsi Que Les Risques 

Inhérents. 

3.  Suitable for wet locations. 

Convient aux emplacements mouilles.

4.  Wall mount only.  

Installation murale seulement

SAVE THESE INSTRUCTIONS 

FOR FUTURE REFERENCE 

MOUNTING OVER RECESSED JUNCTION BOX

NOTE:

 Knockouts are provided for mounting over 3" octagonal or 4" 

octagonal boxes.

1.  Remove lens assembly by loosening screws on side of frame. 

Swing lens assembly open,disconnect quick connect wiring 

connector(s) and lift lens assembly upward to remove from housing.

2.  Drill out appropriate knockouts in back box for attachment to junction 

box. Also drill knockout for wiring access.

NOTE: 

Fixture should not be exclusively supported by junction 

box. Drill additional knockouts toward corners of fixture to provide 

additional support. Do NOT drill within 1/4" (64 mm) from edges of 

fixture.

3.  Pull supply leads from junction box through wall of back box. Attach 

back box to mounting surface using hardware (supplied by others) 

appropriate for mounting surface.

NOTE:

 A high grade caulking material such as silicone rubber, 

should be used around perimeter of back box to prevent water 

leakage into fixture or junction box.

4.  Position switches to select desired CCT and wattage. See 

Figure 1.

 

NOTE:

 Factory setting for wattage is highest setting. Factory setting 

for CCT is 4000K.

5.  Make wiring connections per the 

Electrical Connections

 section.

6.  Replace the lens assembly on hinges, re-connect quick-connect 

wiring connectors, and swing lens into place. Re-tighten screws that 

were loosened in Step 1.

1.  Remove lens assembly by loosening screws on side of frame. 

Swing lens assembly open,disconnect quick connect wiring 

connector(s) and lift lens assembly upward to remove from housing.

2.  Drill holes in four corners of back box to allow for attachment of 

back box to mounting surface. Do NOT drill within 1/4" (64 mm) 

from edges of fixture.

3.  Attach back box to mounting surface using hardware (supplied by 

others) appropriate for mounting surface.

NOTE:

 A high grade caulking material such as silicone rubber, 

should be used around perimeter of back box to prevent water entry.

4.  Remove appropriate threaded plugs on sides of fixture and route 

electrical conduit to the holes desired. Feed the supply leads through 

the conduit and into the back box.

NOTE:

 Use of teflon tape on the conduit threads will ensure a 

watertight seal.

5.  Position switches to select desired CCT and wattage. See 

Figure 1.

 

NOTE:

 Factory setting for wattage is highest setting. Factory setting 

for CCT is 4000K.

6.  Make wiring connections per the 

Electrical Connections

 section.

7.  Replace the lens assembly on hinges, re-connect quick-connect 

wiring connectors, and swing lens into place. Re-tighten screws that 

were loosened in Step 1.

WALL MOUNTED WITH CONDUIT FEED

3L AND 6L

10L AND 16L

FIGURE 1