Regency Wood Products Warranty 

 

Limitations of Liability:  

The original purchaser’s exclusive remedy under this warranty, and FPI’s sole obligation under this warranty, 

express or implied, in contract or in tort, shall be limited to replacement, repair, or refund, as outlined above. IN 

NO EVENT WILL FPI BE LIABLE UNDER THIS WARRANTY FOR ANY INCIDENTAL OR CONSEQUENTIAL COMMERCIAL 

DAMAGES OR DAMAGES TO PROPERTY. TO THE EXTENT PERMITTED BY APPLICABLE LAW, FPI MAKES NO EXPRESS 

WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS 

LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. IF IMPLIED WARRANTIES CANNOT BE 

DISCLAIMED, THEN SUCH WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. 

 

Some U.S. states do not allow limitations on how long an implied warranty lasts, or allow exclusion or limitation of 

incidental or consequential damages, so the above limitations or exclusions may not apply to you. 

 

Customers located outside the U.S. should consult their local, provincial or national legal codes for additional 

terms which may be applicable to this warranty. 

 

How to Obtain Warranty Service:

 

Customers should contact the authorized selling dealer to obtain all warranty and service. In the event the 

authorized selling dealer is unable to provide warranty / service, please contact FPI by mail at the address listed on 

the next page. Please include a brief description of the problem and your address, email and telephone contact 

information. A representative will contact you to make arrangements for an inspection and/or warranty service, by 

an alternative dealer. 

 

Product Registration and Customer Support: 

Thank you for choosing a Regency Fireplace.  Regency strives to be a world leader in the design, manufacture, and 

marketing of hearth products. To provide the best support for your product, we request that you complete a 

product registration form at 

http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx

 within 

ninety (90) days of purchase. 

Summary of Contents for HI1155

Page 1: ...09 28 22 Owner s Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future ref...

Page 2: ...hin the building envelope It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual This heater is designed to burn natural wood...

Page 3: ...le Installation 14 Stainless Steel Smoke Deflector Installation 15 Operating Instructions Seasoned Wood 16 Operating Instructions 17 Draft Control 17 First Fire 17 Fan Operation 18 Ash Disposal 19 Saf...

Page 4: ...ADJACENT PI CES OBLIGATOIRES POUR L INSTALLATION GAINE DE CHEMIN E HOMOLOGU E EN ACIER INOXYDABLE DE 5 5 PO 140mm ou 6 PO 152mm PI CE EN OPTION VENTILATEUR PI CES NO 210 911 210 915 CARACT RISTIQUES L...

Page 5: ...sure appropriate clear ances will be met refer to Masonry and Factory Built Fireplace Clearances sec tion Unit Dimensions with Standard Flue Adaptor 6 152mm Diameter STANDARD FLUE ADAPTOR 172 942 6 15...

Page 6: ...3 8 14 1 16 25 NOTE Before assembling your In sert use these dimensions to ensure appropriate clear ances will be met refer to Masonry and Factory Built Fireplace Clearances sec tion 6 152mm Diameter...

Page 7: ...stible material Extending 16 for US and 18 for Canada measured from the fuel loading door opening Unit HI1150 Adjacent Side Wall to side A Mantel to top B Top Facing to top C Side Facing to side D Min...

Page 8: ...lation of unit 3 Notify your home insurance company that you plan to install a fireplace insert or hearth heater 4 Your fireplace insert is heavy and requires two or more people to move it safely The...

Page 9: ...ce and chimney for any damage or flaws such as burnouts metal or refectory warping 3 Inspection to a minimum of NFPA 211 Level II is recommended All repairs must be made prior to installing an insert...

Page 10: ...r by opening it and lifting it off its hinges Be sure to protect your hearth extension with a heavy blanket or carpet scrap during the installation NOTE You will be required to purchase either the sta...

Page 11: ...right side see Diagrams 1 2 Mounting Bracket Mounting Bracket Gasket Gasket 2 Slide the unit into position leaving partially out to allow for installation of the left and right side surrounds 3 Instal...

Page 12: ...er starting fire 8 Surround adjustments can be made up or down loosen 4 bolts shown on face of unit Diagram 7 and adjust Surround can also be adjusted left or right loosen 4 bolts shown in Diagram 3 a...

Page 13: ...ositions Do not use a grate LyTherm Sheet Order of firebrick install a Rear Firebrick b Firebox floor install brick over LyTherm Sheet c Right and left side Firebricks Fire bricks Size 1 4 1 4 x 7 2 4...

Page 14: ...ir tubes by removing both the bottom right base brick and right side wall brick 5 Install left and right baffle brackets installation of left baffle bracket shown below Baffle Installation 4 Install t...

Page 15: ...osen both bolts and slide deflector downward push deflector to the back wall of the unit and manoeuver out Install new deflector and hand tighten bolts Ensure positive location of the deflector prior...

Page 16: ...s Softer woods like pine spruce and poplar aspen that is cut split and stacked properly in the early spring maybe be ready for burning in the fall Extremely hard woods like oak and maple and large pie...

Page 17: ...n the door and add another 6 or 7 pieces 2 lbs of start up cord wood more to the back Hold door slightly ajar for 30 60 sec to establish flame and then close the door NOTE These steps are crucial to e...

Page 18: ...on again This is too al low the stove to reach it s optimum temperature To operate fan automatically push switch on the right side of fan housing to Auto and second switch on the left to either High o...

Page 19: ...edoorwhenrefuelling the fire 12 Do not connect your unit to any air distribution duct 13 This heater is designed to burn natural wood only Higher efficiencies and lower emis sions generally result whe...

Page 20: ...and chimney system Havethechimneycleanedbeforetheburningseason and as necessary during the season as creosote deposits may build up rapidly Moving parts of your stove require no lubrication 5 The chim...

Page 21: ...er using the 4 screws Do not wrench down on the glass as this may cause the glass to break 7 Place door back on unit Door Removal When handling enamel parts please handle with care as they can be dama...

Page 22: ...rs removed Cleaning Maintaining Your Wood Stove 1 Raise or lower the latch by undoing the inner 2 bolts Adjust to desired location and retighten the 2 bolts make sure the door catch closes freely and...

Page 23: ...released from grip Remove See Diagram 1 4 Remove top left and right metal retainers followed by the fragile three piece C Cast Baffles then remove the remaining 2 tubes Secondary Air Tubes 5 To reins...

Page 24: ...1 Remove 2 front secondary air tubes vermiculite baffles see manual for details 2 Loosen the two 7 16 bolts nuts to remove replace vertical baffle 3 Repeat steps to install new vertical deflector NOT...

Page 25: ...acks Replace if required Clean blower motor Disconnect power supply Remove and clean blower DO NOT LUBRICATE Inspect and clean chimney Annual professional chimney cleaning recommended NOTE Chimney Cle...

Page 26: ...s set of 4 14 940 356 P Glass Replacement Includes Glass Gasket 15 846 686 8 mm Soft Fibre Black Gasket Tape 8 936 238 16 948 467 Hinge Pin Lower 17 210 561 Door Assembly Metallic Black no glass Part...

Page 27: ...6 5 3 7 2 ITEM NO PART NUMBER QTY DESCRIPTION 7 RD 14287 2 3 500 x2 2500 BRICK 6 RD 14286 2 4 250 x 8 000 x 30 DEG BRICK 5 802 147 1 3 500 x 4 500 BRICK 4 802 152 2 2 000 x 9 000 BRICK 3 902 111 3 9...

Page 28: ...ng 1 Catalyst Combustor 10 Years Prorated Venting Chimney 1 Screens 1 See specific warranty details in regards to the catalyst combustor in unit manual Conditions Warranty protects against defect in m...

Page 29: ...rrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts tr...

Page 30: ...tal or consequential damages so the above limitations or exclusions may not apply to you Customers located outside the U S should consult their local provincial or national legal codes for additional...

Page 31: ...or us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Prod...

Page 32: ...32 HI1150 Hampton Wood Cast Insert warranty...

Page 33: ...HI1150 Hampton Wood Cast Insert 33 notes...

Page 34: ...34 HI1150 Hampton Wood Cast Insert notes...

Page 35: ......

Page 36: ...Address ________________________________________ ___________________________________________________________ Installer ____________________________________________________ Phone _____________________...

Reviews: