Fan Operation
The fan is to be operated only with the draft control
rod
pulled out at least 1/2" from the fully
closed position.
The fan is not to be operated
when the draft control rod is in the closed position
(pushed in). The fully closed position is the low
burn setting.
The fan must not be turned on until a fire has
been burning for at least 30 minutes. Also note it
is recommended that the fan be turned off before
each fuel loading and again wait for 30 minutes
before the fan is turned on again. This is too al-
low the stove to reach it's optimum temperature.
To operate fan automatically, push switch on the
right side of fan housing to "Auto" and second
switch, on the left to either "High" or "Low" for
fan speed. The automatic temperature sensor will
engage the blower when the unit is at temperature
and will shut off the blower once the fire has gone
out and the unit has cooled to below a useful heat
output range.
Fan Wiring Diagram
To manually operate the fan system, push the switch
on the left to "Man" and switch on the right to
either "high" or "Low". This will bypass the sensing
device and allow full control of the fan. Switching
from "Auto" to "Manual" or "High" to "Low" may
be done at any time.
Fan Control Location
Auto
|
Man Switch
High|Low|Off
Switch