background image

6

If your ceiling fan does not have an existing UL Listed mounting 
box, then install one using the following instructions:

Disconnect the power by removing the fuses or turning off  
the circuit breakers.

Secure the outlet box (not included) directly to the building 
structure. Use appropriate fasteners and materials (not 
included). The outlet box and its bracing must be able to fully 
support the weight of the moving fan (at least 35 lb.). Do not 
use a plastic outlet box.

The illustrations below show three different ways to mount the 
outlet box (not included).

To hang your fan where there is an existing fixture but no ceiling 
joist, you may need an installation hanger bar (not included) as 
shown above.

Outlet Box

Outlet Box

Hanger Bar

Outlet Box

Recessed

Outlet

Box

A

 

WARNING:

 

To reduce the risk of fire, electric shock, or 

personal injury, mount the fan to an outlet box marked 
acceptable for fan support using the screws provided with the 
outlet box. An outlet box commonly used for the support of 
lighting fixtures may not be acceptable for fan support and 
may need to be replaced. If in doubt, consult a qualified 
electrician.

MOUNTING OPTIONS

Installation

NOTE:

 

You may need a longer downrod to maintain proper 

blade clearance when installing on a steep, sloped ceiling. 
The maximum angle allowable is 18° away from horizontal. If 
the canopy (B) touches the hanger ball/downrod assembly (D), 
remove the decorative canopy bottom cover (C) and turn the 
canopy (B) 180° before attaching the canopy (B) to the mounting 
bracket (A).

Summary of Contents for AK401A-BN

Page 1: ...ng to the store 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday call Hampton Bay Customer Service We appreciate the trust and confidence you have placed in Hampton Bay through the purchase of t...

Page 2: ...trical connections spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding condu...

Page 3: ...esponsibility Damage to any part such as by accident misuse improper installation or by affixing any accessories is not covered by this warranty Because of varying climatic conditions this warranty do...

Page 4: ...n to actual size HARDWARE INCLUDED Pre Installation continued DD AA BB CC AA BB CC DD Plastic wire nut Blade attachment screw and lock washer additional 1 5V AAA battery 3 pin extension cord Part Desc...

Page 5: ...ng bracket preassembled Canopy Canopy bottom cover preassembled Hanger ball downrod assembly Coupling cover Fan motor assembly PACKAGE CONTENTS Pre Installation continued HAMPTONBAY COM Please contact...

Page 6: ...ion hanger bar not included as shown above Outlet Box Outlet Box Hanger Bar Outlet Box Recessed Outlet Box A WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an ou...

Page 7: ...r ball lower the hanger ball and remove the pin Remove all three pieces from the downrod and assemble them onto the new longer downrod before proceeding to the downrod installation Be sure to snap tog...

Page 8: ...F up to the mounting bracket A and seat the hanger ball downrod assembly D in the mounting bracket A socket Make sure the tab on the mounting bracket A socket is properly seated in the groove in the...

Page 9: ...e remote control and the fan s receiving unit NOTE If a longer downrod not included is needed use the extension cord DD to connect with the motor wires and receiver CAUTION Do not use with a wall ligh...

Page 10: ...the loose canopy mounting screws EE on the mounting bracket A Turn the canopy B clockwise until it locks in place at the narrow section of the key holes Make sure the positioning pin JJ on the mounti...

Page 11: ...light kit mounting plate While holding the 20W LED light kit I under the fan motor assembly F snap together the wire connection plugs LL White to white Black to black Position the notches MM in the ou...

Page 12: ...ill start to spin The fan will now accept commands from the added remote If you would like to set the dip switch back to the 0 position after a learning please re pair the remote by following the lear...

Page 13: ...lated Color Temperature CCT changing Push and release the button to cycle through the three color temperature options Option 1 3000K Soft White Option 2 4000K Bright White Option 3 5000K Daylight Fan...

Page 14: ...he remote control holder SS orient the remote control holder SS by lining up the two mounting holes with those on the remote control bracket PP Insert and tighten the screws TT Operation continued INS...

Page 15: ...lide the switch to the left for warm weather operation Slide the switch to the right for cool weather operation Warm weather Counterclockwise Direction A downward air flow creates a cooling effect Thi...

Page 16: ...ble occurs after running the fan for 10 minutes verify blade level using the following process Select a point on the ceiling above the tip of one of the blades then select any fan blade and measure fr...