INSTALLATION AND MAINTENANCE
The organ must be connected to a regulated-frequency source of the voltage and frequency
specified on the name plate. If the frequency is not regulated, the pitch of the organ will be
irregular.
When a console is set up for operation, the anchoring must be loosened so that the generator will
float freely on its spring suspension system. No damage will result if this is not done, but the
console will sound noisy, and the same is true if the anchoring is loosened but the console is not
level. If the console is to be moved a long distance the anchoring should be tightened during such
moves.
Instructions for loosening and tightening the generator in the console are given on the instruction
card contained in the bench.
The tone generator is lubricated by putting oil into cups inside the console. Add oil in accordance
with the instruction within the console.
When placement of console has been completed after loosening of generator, as described above,
the reverberation unit if necklace type should be unlocked by moving its lever "up". The unit should
be again locked whenever the console is moved, even if only a few feet. Consoles, serial number
above 6127 do not require any locking or unlocking operation.
To replace the pilot lamp, remove the back cover, if the console has one. It is a pin type lamp, 6.3
volts, #12.
6