background image

FULLY ELECTRONIC

EXACT MIXING RESULT 

DETECTS EMPTY CONTAINER 

FLEXIBLE HOSE LENGTHS 

AUTOMATIC SWITCH-OFF

I N S T R U C T I O N S

COOLING LUBRICANT MIXING DEVICE MISCEO 3

E N G

+ 4 4

Summary of Contents for Misceo 3

Page 1: ...VOLLELEKTRONISCH EXAKTES MISCHERGEBNIS ERKENNT LEERE GEBINDE FLEXIBLE SCHLAUCHL NGEN AUTOMATISCHE ABSCHALTUNG A N L E I T U N G K HLSCHMIERSTOFF MISCHGER T MISCEO 3 D 4 9 E N G 4 4...

Page 2: ...la lingua del committente Cliccando il seguente link possibile vedere scaricare le istruzioni d uso attuali nella lingua desiderata https www hamma uwt de service produktunterlagen Se avete bisogno di...

Page 3: ...rost ed proto klademe pouze v uku v angli tin n m in a v jazyce z kazn ka Pod n sleduj c m odkazu si m ete st hnout aktu ln n vod v tomto jazyce https www hamma uwt de service produktunterlagen Po adu...

Page 4: ...l naslov info hamma uwt de naprej Prosimo preberite navodila pred uporabo naprave pazljivo RO MANUAL DE UTILIZARE 40 Noi sprijinim mediul prin urmare punem de instruc iuni doar n limba englez german i...

Page 5: ...VOLLELEKTRONISCH EXAKTES MISCHERGEBNIS ERKENNT LEERE GEBINDE FLEXIBLE SCHLAUCHL NGEN AUTOMATISCHE ABSCHALTUNG A N L E I T U N G K HLSCHMIERSTOFF MISCHGER T MISCEO 3 D 4 9...

Page 6: ...Der Druckablass Die Option berlauf berwachung Die Option Schl sselschalter Die Option Automatik Die Option Automatik Anschlussplan Die Option Intelligente Drucksteuerung Die Option Externer Informatio...

Page 7: ...ssspannung Frequenz Ger tespannung Leistung Gewicht Ma e LxBxH Viskosit t Konzentratansaugschlauch Wassereingangsdruck Ausgangsdruck ca 600 bis 2000 l h parameterabh ngig 5 99999 l oder unendlich 0 5...

Page 8: ...sicht walten lassen um eine optimale Funktionsweise und Sicherheit zu gew hrleisten Bitte lesen Sie zu Ihrer eigenen Sicherheit die nachfolgenden Hinweise und die Bedienungsanleitung sorgf ltig durch...

Page 9: ...2 innen Wasserhahnanschluss 3 4 innen Mischungsausgang 1 2 au en Restliche Anschl sse Schnellkupplungen F r einen verrohrten Einsatz entfernen Sie am Misceo 3 die Kupplungsstecker am Wassereingang und...

Page 10: ...Die Bema ung 6 D...

Page 11: ...stellen justieren Sie den Misceo 3 ber den Men punkt Justieren im Hauptmen Refraktometerwert beachten Hat der Misceo 3 den Mischvorgang beendet k nnen Sie w hlen ob Sie erneut mischen ins Hauptmen ode...

Page 12: ...uch mit Fussventil Art Nr 2001107 6 Fassverschraubung 3 Auslaufschlauch Mischung Art Nr 2001105 7 Display 4 Steckernetzger t Art Nr 2001103 8 Tastenblock links rechts Optionen 1 Informationsausgang Ar...

Page 13: ...ierstoffes nicht bekannt oder zur Hand kann eine mittlere Viskosit t von 130 mm s eingestellt werden 2 Mischen Sie zwei Eimer K hlschmierstoff mit je 8 l und 5 an 3 Der erste Eimer wird nicht gemessen...

Page 14: ...Mischvorgangs ausgehen oder beim automatischen Bef llen nicht bereitgestellt werden k nnen so werden Sie in das manuelle Bef llen geleitet Es gibt ein Bef ll Men f r Konzentrat und eines f r Wasser M...

Page 15: ...re Mischdaten eingeben Um den Mischvorgang zu starten geben Sie die gew nschte Konzentration und die Menge ber die Pfeiltasten und die Plus und Minustaste ein Die Kombination Enter und die Plus oder M...

Page 16: ...xtmeldung Vielen Dank Mischvorgang ist beendet Sie k nnen das Ger t jetzt vom Netz trennen anschlie end sollten Sie den Misceo 3 von Wasser und Strom trennen Achtung Die Wasser und Stromzufuhr des Mis...

Page 17: ...vorgang trotz aller Sicherheitseinrichtungen stets durch geschultes Personal zu berwachen Die Kabell nge der berlauf berwachung betr gt 3m Verl ngerungskabel gibt es f r die berlauf berwachung in viel...

Page 18: ...int im Display Sollten Sie bei Ihrem Misceo 3 keinen Schl sselschalter mitbestellt haben so k nnen Sie diesen nachr sten lassen Hierzu ben tigen Sie die Nachr stung Art Nr 2001161 und den Schl sselsch...

Page 19: ...ber Im Bildschirm werden Sie permanent ber den aktuellen Fortschritt informiert Sollte der Maximum Schalter defekt sein gibt der Notaus zus tzliche Sicherheit Beim Bet tigen des Notaus schaltet der Mi...

Page 20: ...ceo 3 f r berlauf berwachung Stop 3 polig Art Nr 72001304 f r Automatik Min 4 polig Art Nr 72001305 f r Automatik Max 5 polig Art Nr 72001306 c Anschlusskabel endlos 2 adrig pro Meter Art Nr 72001311...

Page 21: ...ge vorhanden sein Geht das K hlschmierstoffkonzentrat w hrend des Betriebs aus gehen Sie wie beim Standardger t beim Bef llen vor Im Bildschirm werden Sie permanent ber dem aktuellen Fortschritt infor...

Page 22: ...brauchten Mengen und die Betriebszeit des gesamten Nutzungszeitraums ablesen Diese Z hler k nnen nicht zur ckgesetzt werden Mit der Enter Taste gelangen Sie wieder in das Hauptmen Sollten Sie bei Ihre...

Page 23: ...gung Die Verbindung zum Misceo 3 erfolgt mit einem Anschlussstecker 4 polig Der Anschlussstecker ist im Lieferumfang enthalten b c d a e Anschluss stecker 4 polig Anschluss kabel max 2x0 25mm Kontakt...

Page 24: ...Messing vernickelt Art Nr 72001430 19 mm f r 3 4 Schlauch Messing vernickelt Art Nr 72001431 72001219 Wasserhahnanschluss Messing vernickelt mit Innengewinde 1 2 i Art Nr 72001440 3 4 i Art Nr 7200144...

Page 25: ...r berlauf berwachung 3 polig 72001304 Anschlussstecker f r Automatik Minimum und externen Informationsausgang 4 polig Anschlussstecker f r Automatik Maximum 5 polig 72001306 72001305 Anschlusskabel e...

Page 26: ...rentwickelt Um Ver nderungen am K hlschmierstoff sowie den gesetzlichen Vorschriften gerecht zu werden ist ein Update auf die neuste Software alle 2 Jahre empfohlen Um das Update zu installieren ist d...

Page 27: ...pr fen Sie ob die Siebdichtung Konzentrat im Misceo verbaut sauber ist siehe Serviceanleitung Misceo 3 hat kein Strom bitte berpr fen Sie ob Steckernetzger t eingesteckt ist bitte lassen Sie Ihren Ele...

Page 28: ...rwertes Um die Konzentration des angemischten K hlschmierstoffes korrekt zu bestimmen muss der abgelesene Wert des Refraktometers mit dem Refraktometerwert multipliziert werden Beispiel Ablesewert x R...

Page 29: ...18g 11 178g 22g 13 174g 26g 15 170g 30g Summe Refraktometerwert Anzahl Ermitteln der gemessenen 1 F llen Sie die Wassermenge laut Tabelle in einen Becher abwiegen Bild 1 2 Geben Sie die Konzentratmen...

Page 30: ...gen F llstands berwachung zur automatischen Bef llung Verrohrungskomponenten labscheider lau angbeh lter Mikrobel fter DAS PERFEKTE PFLEGESYSTEM F R IHREN K HLSCHMIERSTOFF CLEAN TOWER MOBILES PFLEGESY...

Page 31: ...ericht mit den Daten Ihres Konzentrates K o n z e n t r a t b e i l e g e n 27 D Bitte hier die Konzentratdaten angeben oder Datenblatt anh ngen Konzentrat Bitte hier die Herstellerdaten angeben oder...

Page 32: ...amma Umwelttechnik Kettelerstra e 44 46 78532 Tuttlingen Germany Armin Hamma Umwelttechnik Kettelerstra e 44 46 D 78532 Tuttlingen Telefon 49 0 7461 965 99 0 Fax 49 0 7461 965 99 49 Mail info hamma uw...

Page 33: ...FULLY ELECTRONIC EXACT MIXING RESULT DETECTS EMPTY CONTAINER FLEXIBLE HOSE LENGTHS AUTOMATIC SWITCH OFF I N S T R U C T I O N S COOLING LUBRICANT MIXING DEVICE MISCEO 3 E N G 4 4...

Page 34: ...itch option Option Automatic mode option Option Automatic mode connection diagram option Option Intelligent pressure control option Option External information output option Option Operation counter O...

Page 35: ...y Device voltage Power Weight Dimensions LxWxH Viscosity Concentrate suction hose Water inlet pressure Outlet pressure approx 600 to 2000 l h depending on parameters 5 99999 l or infinite 0 5 15 0 1 D...

Page 36: ...g ratio during filling is possible When the mixing process is finished the outlet hose is to always be held above the concentrate supply Check the Misceo 3 and its accessories before use A damaged Mis...

Page 37: ...nternal Water tap connection 3 4 internal Mixture outlet 1 2 external Remaining connections Quick action couplings When using piping remove the coupling plug from the water inlet of the Misceo 3 and f...

Page 38: ...Dimensions 6 ENG...

Page 39: ...ing your mixed cooling lubricant adjust the Misceo 3 via the menu item Adjust in the main menu observe the refractometer value Once the Misceo 3 has finished the mixing operation you can choose whethe...

Page 40: ...e with foot valve Art No 2001107 6 Vat screw joint 3 Outlet hose mixture Art No 2001105 7 Display 4 Plug in power supply Art No 2001103 8 Keypad left right Options 1 Information output Art No 2001210...

Page 41: ...the viscosity of your cooling lubricant is unknown or unavailable an average viscosity of 130 mm s can be set 2 Blend two buckets of cooling lubricant each with 8 l and 5 3 The first bucket is not me...

Page 42: ...glasses The manual filling If the concentrate or water runs out during the mixing process or can t be provided during automatic filling so you will be directed in the manual filling There is a filling...

Page 43: ...enu main menu or would like to end with pressure relief If the mixing operation was interrupted it is possible to continue the mixing operation with Next Infinity function If you have installed the au...

Page 44: ...ng operation is ended You can now disconnect your device from the mains after which you should disconnect the water and power from the Misceo 3 Attention The water and power supplies of the mixing dev...

Page 45: ...onitor is in no way a replacement for having the mixing operation continuously supervised by trained personnel The cable length of the overflow monitor is 3 m Extension cables are available for the ov...

Page 46: ...symbol appears on the display If you did not order a key switch with your Misceo 3 you can have this retrofit later For this you will require retrofitting Art No 2001161 and the key switch Art No 2001...

Page 47: ...es back to the work routine On the screen you will be continuously informed about the current progress If the maximum switch should be defective the emergency stop function will provide additional saf...

Page 48: ...eo 3 for overflow monitor stop 3 pin Art No 72001304 for automatic system Min 4 pin Art No 72001305 for automatic system Max 5 pin Art No 72001306 c Connection cable infinite 2 wire per meter Art No 7...

Page 49: ...e mixing volume left If the cooling lubricant concentrate runs out during operation proceed as you would for the standard device during filling On the screen you will be continuously informed about th...

Page 50: ...g time of the entire period of use in lines 4 5 6 These counters cannot be reset Return to the main menu with the enter key If you did not order an operation counter with your Misceo 3 you can have th...

Page 51: ...he connection to the Misceo 3 is made with a connection plug 4 pin The connection plug is included in delivery b c d a e Connection plug 4 pin Connection cable max 2x0 25mm Consumer contact Connection...

Page 52: ...Signaling devices for Misceo 3 Signal lamp for the external information output Art No 2001212 Signal horn for the external information output Art No 2001211 Analog refractometer with LED lighting 0 18...

Page 53: ...tomatic system minimum and external information output 4 pin Connection plug for automatic system maximum 5 pin 72001306 72001305 Connection cable infinite function 2 wire for overflow monitor minimum...

Page 54: ...ons To keep up with the changes to cooling lubricants as well as legal regulations an update to the newest software version is recommended every 2 years To install the update you must send in your Mis...

Page 55: ...the filter seal for the concentrate installed in the Misceo is clean see service instructions Misceo 3 has no power Please check whether the plug in power supply is plugged in Please have your electri...

Page 56: ...e To correctly determine the concentration of the mixed cooling lubricant the read off value from the refractometer must be multiplied with the refractometer value Example Read off value x refractomet...

Page 57: ...7 186g 14g 9 182g 18g 11 178g 22g 13 174g 26g 15 170g 30g Total refractometer value Number Determine the measured 1 Fill the water volume into a beaker according to the table weigh Figure 1 2 Add the...

Page 58: ...portioning device Battery Barell trailer Level monitor controls Piping components Oil skimmer Oil collecting tray Micro aerator THE PERFECT CARE SYSTEM FOR YOUR COOLING LUBRICANT CLEAN TOWER MOBILE CA...

Page 59: ...the data for your concentrate 27 Please specify the concentrate data here or attach data sheet Concentrate Please specify the manufacturer data here or attach data sheet Manufacturer Please enter you...

Page 60: ...Umwelttechnik Kettelerstra e 44 46 78532 Tuttlingen Germany Armin Hamma Umwelttechnik Kettelerstra e 44 46 D 78532 Tuttlingen Telefon 49 0 7461 965 99 0 Fax 49 0 7461 965 99 49 Mail info hamma uwt de...

Reviews: