23
Subject to change without notice
Controls and Readout
The following description presumes that Component Test Mode
is switched off.
1
POWER
Mains switch with symbols
I
= ON and = OFF.
After turning the scope on and after the warm-up time of the
crt heater has elapsed the HAMEG logo, the instrument type
and the version number are displayed. If prior to switching off
the function ”Quick Start“ was selected (SETTINGS
6
>
Misc)
the above will not be displayed. Then the scope will assume the
settings which existed before switching off.
2
INTENS knob
This knob controls various functions:
2.1
Trace intensity if the FOCUS/TRACE/MENU pushbutton
3
does not light or fl ash. Turn left for decreasing and right
for increasing.
2.2
If the FOCUS/TRACE/MENU pushbutton
3
is illuminated the
control will act for those functions displayed in the menu,
which are activated.
3
FOCUS TRACE MENU
(pushbutton)
If the knob symbol
will light after pressing this pushbutton
the Int.Knob menu will be shown.
Depending on the operating mode the menu contains:
A-Int.:
Intensity of the signal as displayed by time base A
B-Int.:
Intensity of the signal as displayed by time base B
RO-Int.:
Readout
intensity
Focus:
Focus for signal and readout
Readout
On Off:
Turning the readout off will eliminate interference
of the readout with the signal(s). The knob symbol
will blink as long as the readout is off. Only menus
and help texts will be shown.
Trace rotation:
Trace rotation (see TR)
After turn-on the readout will always be on.
4
CURSOR MEASURE
(pushbutton)
If the cursors have been switched off, pressing the CURSOR
MEASURE pushbuttones the cursors and the cursor measure-
ment results on. If the cursors and the measurement results are
displayed, pressing the CURSOR MEASURE pushbutton again
then causes the display of the “Cursors” menu and its selection
box. Additionally the FOCUS/TRACE/MENU pushbutton
3
will
HM 1
0
0
0
-2 - KLB - Stand: 07/1
2
/06 gw
HM1
0
0
0 - blau - Stand: 07/1
2
/06 gw
HM
10
0
0
-2
- gr
ü
n -
St
an
d
:
07/1
2
/06
gw
VAR
VAR
VAR
x10
FOCUS
TRACE
VOLTS / DIV
VAR
VOLTS / DIV
VAR
TIME / DIV
VAR
X-POS
INTENS
!
LEVEL A/B
MENU
AUX
AUXILIARY INPUT
HORIZONTAL
INPUTS
1M
Ω
II15pF
max
400 Vp
CAT I
!
CAT I
!
DELAY
TRACE
SEP
CH 1/2
CURSOR
SAVE/
RECALL
AUTOSET
SETTINGS
HELP
POSITION 1
POSITION 2
VERT/XY
HM1500-2
ANALOG
OSCILLOSCOPE
150 MHz
TRIGGER
MODE
FILTER
SOURCE
TRIG
’
d
NORM
HOLD OFF
AUTO
MEASURE
CURSOR
MEASURE
TRIG. EXT. / Z-INP.
CH 1
CH 2
X-INP
CH 1
CH 2
HOR
MAG
1M
Ω
II
15pF
max
100 Vp
20 V
1 mV
20 V
1 mV
0.5s
50ns
POWER
POWER
MENU
MENU
OFF
OFF
1
2
3
4
5
8
7
6
9
10
11
13
12
14
15
22
23
16
17
24
18
21
25
26
19
20
27
30
28
29
31
32
33
37
C o n t r o l s a n d R e a d o u t