HF2013DX-A HF AMPLIFER INSTRUCTION MANUAL
Page 28 of 37
INDICATION OF FAULT CONDITIONS
The HF2013DX-A has the following indicationson the front LCD panel:
G2
Measure of the Grid current.
HV
Measure of anode voltage by LCD graph
IA
Measure of anode currency by bar graph
FAULT
Fault Condition – See RED flashing indicators.
OPR
Amplifier in operation mode
STBY
Amplifier in standby mode
WAIT
Heating tube after switching on – Please wait 150sec
TEMP
Measuring of the tube exhaust temperature
G1MAX
Grid Current exceeded maximum
Should a fault condition appear during the tuning or operation of the amplifier the
safetycircuits of HF2013DX-A will react. The amplifier will be turned to
STBY
mode. After
approx. 5seconds the control circuits will switch the amplifier back to
OPR
. If the fault repeat 3
times, the control circuits will turn the amplifier to
STBY
. You must toggle the
OPR/STBY
switch to reset this fault condition. After the reaction of safety circuits the
FAULT
LCD will be lit
up for approx. 5 to 10 secdepending on the nature of the fault.
FLASHING LCD SIGNALS:
IP
anode current exceeded
HV
low anode voltage
FAULT
reflected output exceeded
GRID MAX
first grid current exceeded
screen grid current exceeded
GRID MAX + HV
maximum load power exceeded
HV + IP
tuning fault, incorrect tuning of the Pi-L output circuit
In case your HF2013DX-A amplifier is not working correctly, please contactthe manufacturer
or your distributor.
Summary of Contents for HF2013DX-A
Page 2: ...HF2013DX A HF AMPLIFER INSTRUCTION MANUAL Page 2 of 37 Instruction Manual Version 1 09...
Page 29: ...HF2013DX A HF AMPLIFER INSTRUCTION MANUAL Page 29 of 37 EXAMPLE OF CONNECTION TO AN ICOM...
Page 30: ...HF2013DX A HF AMPLIFER INSTRUCTION MANUAL Page 30 of 37 EXAMPLE OF CONNECTION FOR ELECRAFT...
Page 31: ...HF2013DX A HF AMPLIFER INSTRUCTION MANUAL Page 31 of 37 EXAMPLE OF CONNECTION WITH YEASU...
Page 37: ...HF2013DX A HF AMPLIFER INSTRUCTION MANUAL Page 37 of 37 BLOCK DIAGRAM...