PSx3xxDP Instruction Manual
15
7.1.3 Motor supply voltage OK
The power supply to the motor is higher than the value indicate
d in the ‘min. supply voltage’
parameter. This bit must be set prior to performing a run. The level of the supply voltage has a
significant effect on the torque and/or motor speed.
7.1.4 Ready
Supply voltages, temperature and target position are all in the permissible range and the drive
can begin operation. An exception here is when the display indicates a hardware error, which the
operator must acknowledge (thereby deleting the error message) before performing the run.
7.1.5 Hardware error
This bit is set if an error is detected during an internal process and causes the drive to stop. The
‘error status’ parameter can be used to determine the source of the error. This bit can be deleted
by temporarily deactivating the release bit in the command byte, an action that causes the error
to be recorded in an internal error memory. The ‘save’ command can be used to save this error
memory in the instrument’s non-volatile EEPROM.
7.1.6 Positioning run aborted
The positioning run has been aborted, either because the release bit was reset or because of an
error.
7.1.7 Jog key, down
This bit indicates that the ‘down’ jog key has been depressed. A manual run can be performed
directly either if the ‘manual run release’ bit in the command byte has been activated or if the
manual run was released when setting parameters and the positioning bit has not been set.
7.1.8 Jog key, up
This bit indicates that the ‘up jog key’ input has been activated (connected to +24V). A manual
run can be performed directly either if the ‘manual run release’ bit in the command byte has been
activated or if the manual run was released when setting parameters and the positioning bit has
not been set.
7.1.9 Temperature too high
The PSx3xxDP positioning unit is equipped with a simple temperature monitoring device
intended to avoid a thermal overload. This bit is set if the temperature inside the instrument
exceeds the temperature limit set in the parameters; new positioning runs can only be performed
once the instrument has cooled down (the 'temperature too high' bit is reset). The 'temperature
too high' bit must be reset with the confirmation bit.