2.3
GENERAL SPECIFICATIONS
Appliance
Club HE 18
Total weight (full)
kg
44.1
T
otal weight (empty)
kg
42.0
Max lift weight
kg
41.0
T
otal water capacity
Ltr
1.8
Integral expansion vessel capacity
Ltr
8
Maximum heating system water content
using fitted expansion vessel, @ 0.75 bar
Ltr
84
Electrical supply
230V 50Hz
Inter
nal fuse
T4H 4A 250V
Maximum power consumption
W
106
IP Rating
IP20
Flue gas temperatur
e Nat Gas 50/30
°
C
53
CO
2
value max rate (Nat Gas) (G20)
%
9.2 ± 0.3 case on
9.0 ± 0.2 case off
CO
2
value min rate (Nat Gas) ref only (G20)
%
8.6 ± 0.3
CO/CO
2
Ratio max rate (Nat Gas) (G20)
%
0.0011 + 0.0014
Flue pr
oducts mass flow rate (Nat Gas) (G20)
g/s
14.7
Gas V
alve Offset @ min rate
Pa
-5.0
Connections
Gas
15 mm compr
ession
CH flow
22 mm compr
ession
CH r
eturn
22 mm compr
ession
Pr
essure relief valve outlet
15 mm compr
ession
Condensate Drain
21.5 - 22 mm plastic over
flow pipe
3
NOTE: THE ST
ATED HEAT INPUT AND CO2 VALUES ARE NOMINAL AND MAY VARY BY ± 5-10% WHEN THE APPLIANCE IS
RUN WITH LINE GAS, DUE TO FLUCTUATIONS IN GAS QUALITY.