background image

97884C (Rev. A - 3/06)

PAGE 9

RC8AQ*A     RC12AQ*A

INSTALLATION INSTRUCTIONS

FOR THE

RC MODEL DRINKING FOUNTAIN

(Cup Dispenser With Glass Filler)

1. 

The 14700

 Model Cup Dispenser with Glassfiller is designed to complement model RC drinking fountains. The

fountain should already be installed before beginning installation. If not refer to page 2 for your model. Remove
louvered access panel from fountain via the two screws at the bottom.

2. 

Check

 wall opening to see if provisions have been made to accept this cup dispenser. If they have not, refer to

page 2 for rough-in instructions. CAUTION: Wall construction must be framed to support fountain and cup dis-
penser (approximately 150 pounds).

3. 

See

 Parts List Illustration (page 10) for cup dispenser tailpiece. Decide which style of waste trap you intend to use.

For easier installation, we recommend the use of a swivel trap.

4. 

Orientate

 yourself to the configuration of the cup dispenser. Open front door and remove the spring loaded trash

access panel. To remove access panel, just loosen the four mounting screws and pull out the panel. Also remove
the waste bin. Note location of mounting slots in the wall box portion of the cup dispenser. The slots are for affixing
wallbox to building construction.

5. 

Put

 cup dispenser in wall opening. Determine shimming required to obtain a good alignment with fountain. Open

and close door to ensure proper operation. CAUTION: Do not “suspend” cup dispenser via the mounting slots - be
sure to shim along bottom edge to bear the weight of the cup dispenser.

6. 

Secure

 cup dispenser in place. Use lag screws or bolts as required by wall construction.

7. 

Install

 glass filler supply tube assembly. (See Figure 13). Put glass filler fitting through hole provided in back, put

gasket on from the front and screw on the hexagonal mounting nut.

8. 

Install

 glass filler. First remove the blue handle, then screw the glass filler into the glass filler fitting. Reattach blue

handle.

9. 

Make connections between remote chiller outlet tube and fountain.

 Outlet port is marked on the

chiller (1/4” O.D. copper tube). Install a 1/4” x 1/4” tee (provided) on the marked chiller outlet port. Insert the 1/4”
poly tubing coming from the fountain into the tee. Connect glass filler line to outlet on tee. Install a 1/4” x 3/8” union
(provided) on the glass filler outlet line. Insert a piece of 1/4” poly tubing from the tee to the union. Turn on the
water supply and check for leaks.

 DO NOT SOLDER TUBES INSERTED INTO THE UNION/TEE AS DAMAGE TO THE

O-RINGS MAY RESULT.

 (See Fig. 9)

10. 

Install

 tailpiece assembly (as shown in Figure 14). Connect waste trap (not provided).

11. 

Turn

 on supply water and operate push button valve and glass filler. Check entire system for leaks.  Water flow

from the glass filler can be adjusted by turning the flow adjusting screw (See Figure 13). In order to adjust, it may
be necessary to remove, and then reinstall the glass filler, per step 8 above.

12. 

Replace

 the spring loaded trash access panel via the four mounting screws. Reinstall louvered grill on the

fountain.

Summary of Contents for RC8AQA

Page 1: ...NT INSTALLER PLEASE NOTE THE GROUNDING OF ELECTRICAL EQUIPMENT SUCHAS TELEPHONE COMPUTERS ETC TO WATER LINES ISA COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILD...

Page 2: ...cup dispenser model without glass filler plumbing continue with step no 5 4 Cup dispenser Models Install rough plumbing to cup dispenser See Fig 15 for location of waste water outlet 5 Cut plastic ti...

Page 3: ...sted to meet local codes see Step No 1 of installation instructions height dimensions must be adjusted accordingly LEGEND A 1 4 O D TUBE CONNECT CHILLER WATER OUTLET B 3 8 O D TUBE CONNECT CHILLER WAT...

Page 4: ...MAYRESULT See Fig 8 Make connections between remote chiller outlet tube and fountain Outlet port is marked on the chiller 1 4 O D copper tube Install a 1 4 x 1 4 union provided on the marked chiller...

Page 5: ...ll lower stream height For best adjustment stream height should be approxi mately 1 1 2 38mm above the bubbler guard See Fig 6 12 Connect refrigeration unit to electrical supply and check for proper o...

Page 6: ...Rev A 3 06 RC12A TO BUBBLER CHILLER OUTLET 20 16 23 FIG 8 FIG 9 FIG 10 TO BUBBLER CHILLERINLET CHILLEROUTLET 20 24 23 9 TO GLASSFILLER TO BUBBLER CHILLERINLET CHILLER OUTLET 20 16 25 20 CHILLER INLET...

Page 7: ...waste bin 2 Shim along the bottom and side of cup dispenser as required to obtain a good alignment with previously installed drinking fountain Be sure to check for proper operation of access door befo...

Page 8: ...en adjusted to meet local codes see Step No 1 of installation instructions height dimensions must be adjusted accordingly LEGEND A 1 4 O D TUBE CONNECT CHILLER WATER OUTLET B 3 8 O D TUBE CONNECT CHIL...

Page 9: ...suspend cup dispenser via the mounting slots be sure to shim along bottom edge to bear the weight of the cup dispenser 6 Secure cup dispenser in place Use lag screws or bolts as required by wall cons...

Page 10: ...12 Disp Cup w GF Provisions See Fig 11 Assy Valve Push Back Nut Hex Gasket Gasket Drain Gasket Slip Nut Nut Hex Strainer Plate Tailpipe 1 1 4 x 4 Nut Slip 1 1 2 Plug Drain 1 1 2 GF Tube for 14700 Dis...

Page 11: ...been adjusted to meet local codes See Step No 1 of installation instructions height dimensions must be adjusted accordingly LEGEND A 1 4 O D TUBE CONNECT CHILLER WATER OUTLET B 3 8 O D TUBE CONNECT C...

Page 12: ...sy Bubbler 8880 Fitting Union 1 4 Fitting Union 1 4 x 3 8 Fitting Tee 1 4 Sound Dampening Pad TROUBLE SHOOTING AND MAINTENANCE Orifice Assy Mineral deposits on orifice can cause water flow to spurt or...