![Halsey Taylor RC8AQA Owner'S Manual Download Page 5](http://html1.mh-extra.com/html/halsey-taylor/rc8aqa/rc8aqa_owners-manual_3573296005.webp)
97884C (Rev. A - 3/06)
PAGE 5
RC8AQ*A RC12AQ*A
FIG. 7
CORRECT STREAM HEIGHT
FIG. 6
BASIN INSTALLATION
11.
Check
stream height from bubbler. Stream height is factory set at 45 – 50 PSI. If supply pressure varies greatly
from this, remove items 14 & 15 and adjust screw on regulator (item 11). Clockwise adjustment will raise stream
height and CCW adjustment will lower stream height. For best adjustment, stream height should be approxi-
mately 1-1/2” (38mm) above the bubbler guard. (See Fig. 6)
12.
Connect
refrigeration unit to electrical supply and check for proper operation. WARNING: Adequate space must
be maintained behind the refrigeration unit for air circulation.
13.
Attach
regulator holder (item 10) to grill (item 3) with hex nut (item 13). Hold grill and engage angle on top edge
of grill with lower edge of basin. Swing bottom of grill into place against the wall and securing grill mounting
screws (provided).