background image

PAGE 2

RC8AQ*A     RC12AQ*A

97884C (Rev. A - 3/06)

FIG. 3

FIG. 4

1.  

Cut

 a wall opening 24 7/8 W x 48 1/2 H (with cup dispenser), 17 1/8 W x 48 1/2 H (without cup dispenser). The bottom

edge of the opening should be approx. 16 1/8” above the floor (See Fig. 3 with cup dispenser). See Fig. 4 without cup
dispenser.  Check local codes for height requirement.

2.  

After

 opening is completed, reinforce opening on all sides so that it may adequately support water cooler which

weighs up to 150 lbs. and also provides a means of securing Wall Frame in place.  (Install a wall stud indicated on
Fig. 3 (with cup dispenser).  NOTE: Building construction must allow for adequate airflow on both sides and top of
chiller unit. 4” minimum required.

3.  

Install

 rough plumbing to fountain.  See Fig. 5 for location of supply water inlet to chiller and location of waste water

outlet.

   

*For cup dispenser model without glass filler plumbing, continue with step no. 5.

4.  

(Cup dispenser Models)

  Install rough plumbing to cup dispenser.  See Fig. 15 for location of waste water outlet.

5.  

Cut

 plastic ties holding chiller shelf support rods to framework.

6.  

Install

 wall frame assembly in wall opening with front edge of frame flush with finished wall face.  Secure frame

through holes in top and sides to wall support members with 5/16” diameter fasteners (bolts or lag screws) as
required by wall constructions. (14) bolts/screws required.  CAUTION: DO NOT USE LESS THAN REQUIRED
QUANTITY AND SIZE (DIAMETER) OF FASTENERS.

7.  

Install

 chiller shelf.  Place shelf on lower frame member and attach support rods.  Secure front edge of the frame and

wall construction using two 5/16” diameter lag screws or bolts.  Tighten securely.

8.  

Install

 electrical conduit.  Fig. 5 shows electrical conduit connection location.

9.  

Now

 you are ready to install fountains.

WALL FRAME INSTALLATION INSTRUCTIONS

FOR THE

RC MODELS DRINKING FOUNTAIN

(with and without cup dispenser)

Summary of Contents for RC8AQA

Page 1: ...NT INSTALLER PLEASE NOTE THE GROUNDING OF ELECTRICAL EQUIPMENT SUCHAS TELEPHONE COMPUTERS ETC TO WATER LINES ISA COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILD...

Page 2: ...cup dispenser model without glass filler plumbing continue with step no 5 4 Cup dispenser Models Install rough plumbing to cup dispenser See Fig 15 for location of waste water outlet 5 Cut plastic ti...

Page 3: ...sted to meet local codes see Step No 1 of installation instructions height dimensions must be adjusted accordingly LEGEND A 1 4 O D TUBE CONNECT CHILLER WATER OUTLET B 3 8 O D TUBE CONNECT CHILLER WAT...

Page 4: ...MAYRESULT See Fig 8 Make connections between remote chiller outlet tube and fountain Outlet port is marked on the chiller 1 4 O D copper tube Install a 1 4 x 1 4 union provided on the marked chiller...

Page 5: ...ll lower stream height For best adjustment stream height should be approxi mately 1 1 2 38mm above the bubbler guard See Fig 6 12 Connect refrigeration unit to electrical supply and check for proper o...

Page 6: ...Rev A 3 06 RC12A TO BUBBLER CHILLER OUTLET 20 16 23 FIG 8 FIG 9 FIG 10 TO BUBBLER CHILLERINLET CHILLEROUTLET 20 24 23 9 TO GLASSFILLER TO BUBBLER CHILLERINLET CHILLER OUTLET 20 16 25 20 CHILLER INLET...

Page 7: ...waste bin 2 Shim along the bottom and side of cup dispenser as required to obtain a good alignment with previously installed drinking fountain Be sure to check for proper operation of access door befo...

Page 8: ...en adjusted to meet local codes see Step No 1 of installation instructions height dimensions must be adjusted accordingly LEGEND A 1 4 O D TUBE CONNECT CHILLER WATER OUTLET B 3 8 O D TUBE CONNECT CHIL...

Page 9: ...suspend cup dispenser via the mounting slots be sure to shim along bottom edge to bear the weight of the cup dispenser 6 Secure cup dispenser in place Use lag screws or bolts as required by wall cons...

Page 10: ...12 Disp Cup w GF Provisions See Fig 11 Assy Valve Push Back Nut Hex Gasket Gasket Drain Gasket Slip Nut Nut Hex Strainer Plate Tailpipe 1 1 4 x 4 Nut Slip 1 1 2 Plug Drain 1 1 2 GF Tube for 14700 Dis...

Page 11: ...been adjusted to meet local codes See Step No 1 of installation instructions height dimensions must be adjusted accordingly LEGEND A 1 4 O D TUBE CONNECT CHILLER WATER OUTLET B 3 8 O D TUBE CONNECT C...

Page 12: ...sy Bubbler 8880 Fitting Union 1 4 Fitting Union 1 4 x 3 8 Fitting Tee 1 4 Sound Dampening Pad TROUBLE SHOOTING AND MAINTENANCE Orifice Assy Mineral deposits on orifice can cause water flow to spurt or...

Reviews: