5
97880C - 2/05
HRFEREEQ*C HRFEREEQ*2C HRFSEREEQ*C
5.
Install the frame assembly squarely in wall
opening
with frame upright support edges flush with the finished wall
face. Secure the frame to the wall through holes with (12)
5/16” bolts or screws (not provided). Tighten securely.
NOTE:
Be sure that frame is squared in location. Do not
use less than required screw quantity and size.
6.
Attach the chiller shelf support rods
to the right side of
the frame uprights at the second set of holes counting from
the bottom and to the shelf at the (2) side holes. Line up the
other shelf holes with the frame bottom holes and fasten the
assembly to the wall opening using appropriately sized
screws or bolts and nuts (not provided).
MODEL HRFSER-EE-Q
FINISHED FLOOR
18"
457mm
5/8"
16mm
12 1/4"
311mm
12"
305mm
1"
25mm
11"
279mm
18 3/4"
476mm
9 3/8"
238mm
1 1/8"
29mm
3 1/8"
80mm
MINIMUM DEPTH
BACK WALL LINE
WALL LINE
5 5/8"
143mm
D
C
A
B
FLEXIBLE CONDUIT
(BY OTHERS)
E
4 1/2"
114mm
8"
203mm
31 1/4"
793mm
37 1/4"
945mm
27"
685mm
ADA
REQUIREMENT
33"
838mm
HRF-SR
33 1/2"
850mm
HRF-EE
1 1/2"
38mm
39 1/2"
1003mm
HRF-SR
1 1/2"
38mm
Legend
Item
Description
A
1/4” O.D. Tube - Water Outlet Connection
B
3/8” O.D. Tube - Water Inlet Connection
C
1-1/4” O.D. Waste Tube
D
Electrical Inlet on Chiller
E
Electrical Outlet Location. Additional UL/CSA listed grounded outlet (By others)
required for 115 Volt, 60Hz.
Figure 6 – HRFSER-EE-Q Rough-In Dimensions